• Title/Summary/Keyword: constant output

Search Result 1,064, Processing Time 0.023 seconds

Analysis and Control of A Fixed Frequency LCL-type Isolated Bidirectional Converter (고정주파수 LCL타입 절연형 양방향 컨버터 해석 및 제어)

  • Park, Sangeun;Cha, Hanju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.65-72
    • /
    • 2016
  • This paper discussed the LCL-type & Isolated bidirectional dc-dc converter(BDC) with dual full bridge inverter. In order to verify the analysis of the BDC, Experimental prototype has been designed and implemented to supply constant voltage regardless of loads and proposed a method to select switching frequency that depended on two inductors' inductance ratio and transformer parameters. The proposed converter has been composed of LCL resonant network with unit inductance ratio ($L_r/L_f$=1) and then operated with fixed duty, 50% duty ratio and fixed frequency. There are some characteristics that input voltage and output voltage of the BDC is nearly identical and zero voltage turn-on switching is possible in forward and reverse mode. Finally, it has been showed that BDC is possible to commutate operating mode normally and provide constant output voltage in selected switching frequency.

Digital Control of Secondary Active Clamp Phase-Shifted Full-Bridge Converters

  • Che, Yanbo;Ma, Yage;Ge, Shaoyun;Zhu, Dong
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.421-431
    • /
    • 2014
  • A DSP-based self-adaptive proportional-integral (PI) controller to control a DC-DC converter is proposed in this paper. The full-bridge topology is adopted here to obtain higher power output capability and higher conversion efficiency. The converter adopts the zero-voltage-switching (ZVS) technique to reduce the conduction losses. A parallel secondary active clamp circuit is added to deal with the voltage overshoot and ringing effect on the transformer's secondary side. A self-adaptive PI controller is proposed to replace the traditional PI controller. Moreover, the designed converter adopts the constant-current and constant-voltage (CC-CV) output control strategy. The secondary active clamp mechanism is discussed in detail. The effectiveness of the proposed converter was experimentally verified by an IGBT-based 10kW prototype.

A Study on Optimal Selection of Inductance for Power Factor Improvement of Buck AC/DC LED Driver With Wide Input Voltage Range (입력 전압 범위가 넓은 벅 AC/DC LED 구동기의 역률 개선을 위한 최적 인덕턴스 선택에 관한 연구)

  • Kim, Marn-Go
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.302-305
    • /
    • 2021
  • Selection of the optimal inductance for power factor improvement of a buck AC/DC light-emitting diode (LED) driver with wide input voltage range is described in this study. The power factor change based on the slope compensation is obtained for various normalized output current (NOC) values using discrete-time domain analysis. The possibility of implementing constant slope compensation is described using power factor curves for various NOC values. NOC = 0.5 is chosen for the value of inductance with consideration for the simple implementation and reduction of inductor size. Experimental results of the inductance corresponding to NOC = 0.5 are presented.

A Method to Determine the Droop Constant of DGs Considering the Configuration and Active Power Control Mode (분산전원의 구성 및 출력 제어 방법에 따른 Droop 계수 설정 방법)

  • Ahn, Seon-Ju;Park, Jin-Woo;Chung, Il-Yop;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1954-1961
    • /
    • 2008
  • Microgrid usually consists of a cluster of distributed generators(DGs), energy storage systems and loads, and can operate in the grid-connected mode and the islanded mode. This paper presents detailed descriptions of two different options for controlling the active power of DGs in the microgrid. One is regulating the power injected by the unit to a desired amount(Unit output power control) and the other is to regulate the flow of active power in the feeder where the unit is installed to a constant(Feeder flow control). Frequency-droop characteristics are used to achieve good active power sharing when the microgrid operates in the islanded mode. The change in the frequency and the active power output of DGs are investigated according to the control mode and the configuration of DGs when the microgrid is disconnected from the main grid. From the analysis, this paper proposes a method to determine the droop constant of DGs operating in the feeder flow control mode. Simulation results using the PSCAD/EMTDC are presented to validate the approach, which shows good performance as opposed to the conventional one.

Study of the Constant Current Fuzzy Control System Design using CRS Algorithm during Inverter DC Resistance Spot Welding Process (인버터 DC 저항점용접 공정에서 CRS 알고리즘을 이용한 정전류 퍼지 제어시스템 설계에 관한 연구)

  • Park, Hyoung-Jin;Park, Pyeong-Won;Yu, Ji-Young;Kim, Dong-Cheol;Kang, Mun-Jin;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.28 no.6
    • /
    • pp.76-83
    • /
    • 2010
  • The purpose of this study is to propose a method to decide near-optimal settings of the constant current fuzzy control parameters using a controlled random search. This method tries to find the near-optimal settings of the constant current fuzzy control parameters through experiments. It has an advantage of being able to carry out searches in the search domain which includes some irregular points. The method suggested in this study was used to determine the fuzzy control parameters by which the desired welding current were formed during inverter DC resistance spot welding. The output variable was the ITAE (integral of time multiplied by the absolute error). This output variable was determined according to the input variables, which are the GE, GDE, and GDU. This study described how to obtained near-optimal welding current condition over a wide search space conducting a relatively small number of experiments.

Stabilizing Control of DC/DC Buck Converters with Constant Power Loads in Continuous Conduction and Discontinuous Conduction Modes Using Digital Power Alignment Technique

  • Khaligh Alireza;Emadi Ali
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.63-72
    • /
    • 2006
  • The purpose of this raper is to address the negative impedance instability in DC/DC converters. We present the negative impedance instability of PWM DC/DC converters loaded by constant power loads (CPLs). An approach to design digital controllers for DC/DC converters Is presented. The proposed method, called Power Alignment control technique, is applied to DC/DC step-down choppers operating in continuous conduction or discontinuous conduction modes with CPLs. This approach uses two predefined state variables instead of conventional pulse width modulation (PWM) to regulate the output voltage. A comparator compares actual output voltage with the reference and then switches between the appropriate states. It needs few logic gates and comparators to be implemented thus, making it extremely simple and easy to develop using a low-cost application specific integrated circuit (ASIC) for converters with CPLs. Furthermore, stability of the proposed controllers using the small signal analysis as well as the second theorem of Lyapunov is verified. Finally, simulation and analytical results are presented to describe and verify the proposed technique.

Aerodynamic assessment of airfoils for use in small wind turbines

  • Okita, Willian M.;Ismail, Kamal A.R.
    • Advances in Energy Research
    • /
    • v.6 no.1
    • /
    • pp.35-54
    • /
    • 2019
  • A successful blade design must satisfy some criterions which might be in conflict with maximizing annual energy yield for a specified wind speed distribution. These criterions include maximizing power output, more resistance to fatigue loads, reduction of tip deflection, avoid resonance and minimize weight and cost. These criterions can be satisfied by modifying the geometrical parameters of the blade. This study is dedicated to the aerodynamic assessment of a 20 kW horizontal axis wind turbine operating with two possible airfoils; that is $G{\ddot{o}}ttingen$ 413 and NACA 2415 airfoils (the Gottingen airfoil never been used in wind turbines). For this study parameters such as chord (constant, tapered and elliptic), twist angle (constant and linear) are varied and applied to the two airfoils independently in order to determine the most adequate blade configuration that produce the highest annual energy output. A home built numerical code based on the Blade Element Momentum (BEM) method with both Prandtl tip loss correction and Glauert correction, X-Foil and Weibull distribution is developed in Matlab and validated against available numerical and experimental data. The results of the assessment showed that the NACA 2415 airfoil section with elliptic chord and constant twist angle distributions produced the highest annual energy production.

A CMOS Hysteretic DC-DC Buck Converter with a Constant Switching Frequency

  • Jeong, Taejin;Yoon, Kwang S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • This paper describes a CMOS hysteretic DC-DC buck converter with a constant switching frequency for mobile applications. The inherent problems of a large output ripple voltage that the conventional hysteretic DC-DC buck converters has faced have been resolved by using the proposed DC-DC buck converter which employed a ramp generator circuit to be able to increase a switching frequency. The proposed architecture enables the settling response time of charge pump circuit within the converter to become less than 6us suitable for mobile applications. The proposed DC-DC buck converter was implemented by using 0.35 um BCDMOS process and die size was $1.37mm{\times}1.37mm$. The measurement results showed that the proposed circuit received the input of 3.7 V and generated output of 1.2 V with the output ripple voltages less than 20 mV under load currents of 100~400 mA at the fixed switching frequency of 2 MHz. The maximum efficiency of the proposed hysteretic buck converter was measured to be around 93%.

Multiple-Output Low Drop-Out Regulator With Constant Feedback Factor (고정 피드백 인자를 사용하는 다중출력 LDO 레귤레이터)

  • Mo, Hyunsun;Kim, Daejeong
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.384-392
    • /
    • 2018
  • A multiple-output LDO regulator is a good choice in terms of the efficiency in embedded systems requiring various supply voltages. A small feedback factor in LDO incurs the long settling time, resulting in large ripples in the time-multiplexing strategy. A new proposed topology enhances the settling time, and hence the ripples by incorporating the constant feedback factor with different reference voltages. The simulation results of a prototype design in a standard $0.35{\mu}m$ CMOS process verify that the proposed strategy enhances the settling time and ripple characteristic by more than doubled than a conventional circuit using the feedback factor of less than 0.4.

Output Voltage Ripple Analysis and Design Considerations of Intrinsic Safety Flyback Converter Based on Energy Transmission Modes

  • Hu, Wei;Zhang, Fangying;Xu, Yawu;Chen, Xinbing
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.908-917
    • /
    • 2014
  • For the purpose of designing an intrinsic safety Flyback converter with minimal output voltage ripple based on a specified output current, this paper first classified the energy transmission modes of the system into three sorts, namely, the Complete Inductor Supply Mode-CCM (CISM-CCM), the Incomplete Inductor Supply Mode-CCM (IISM-CCM) and the Incomplete Inductor Supply Mode-DCM (IISM-DCM). Then, the critical secondary self-inductance assorting the three modes are deduced and expressions of the output voltage ripples (OVR) are presented. For a Flyback converter with constant loads and switching frequency, it is shown that the output voltage ripple in the CISM-CCM is the smallest and that it has no relationship with the secondary self-inductance. Otherwise, the OVR of the other two modes are bigger than the previously mentioned one. It is concluded that the critical inductance between the CISM-CCM and the IISM-CCM is the minimal secondary self-inductance to ensure the smallest output voltage ripple. At last, a design method to guarantee the minimum OVR within the scales of the input voltage and load are analyzed, and the minimum secondary self-inductance is proposed to minimize the OVR. Simulations and experiments are given to verify the results.