• Title/Summary/Keyword: conservative conditions

Search Result 392, Processing Time 0.022 seconds

Effect of Nozzle on Leak-Before-Break Analysis Result of Nuclear Piping (노즐이 원자력 배관의 파단전누설 해석 결과에 미치는 영향)

  • Kim, Yeong-Jin;Heo, Nam-Su;Gwak, Dong-Ok;Yu, Yeong-Jun;Pyo, Chang-Ryul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.11
    • /
    • pp.2796-2803
    • /
    • 2000
  • For traditional Leak-Before-Break(LBB) analyses, symmetric conditions were assumed for a pipe-nozzle interface to simplify the analysis in calculating J-integral. However. this assumption could result in an overly conservative design criteria for a pipe-nozzle interface, Since the pipe-nozzle interface is asymmetric due to the difference of stiffness between pipe and nozzle, it is required to develop a new methodology considering the nozzle effect. The objective of this paper is to evaluate the effect of nozzle no the development of LBB design criteria for nuclear pipings. For this purpose, extensive finite element analysis were performed to evaluate the effect of nozzle on Crack Opening Area(COA), Detectable Leakage Crack(DLC) length and J-integral values. In conclusion, it was proven that the application of LBB concept could be extended for more nuclear piping system by considering the nozzle.

An Assessment on the Containment Integrity of Korean Standard Nuclear Power Plants Against Direct Containment Heating Loads

  • Seo, Kyung-Woo;Kim, Moo-Hwan;Lee, Byung-Chul;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.468-482
    • /
    • 2001
  • As a process of Direct Containment Heating (DCH) issue resolution for Korean Standard Nuclear Power Plants (KSNPs), a containment load/strength assessment with two different approaches, the probabilistic and the deterministic, was performed with all plant-specific and phenomena-specific data. In case of the probabilistic approach, the framework developed to support the Zion DCH study, Two-Cell Equilibrium (TCE) coupled with Latin Hypercubic Sampling (LHS), provided a very efficient tool to resolve DCH issue. In case of the deterministic approach, the evaluation methodology using the sophisticated mechanistic computer code, CONTAIN 2.0 was developed, based on findings from DCH-related experiments or analyses. For three bounding scenarios designated as Scenarios V, Va, and VI, the calculation results of TCE/LHS and CONTAIN 2.0 with the conservatism or typical estimation for uncertain parameters, showed that the containment failure resulted from DCH loads was not likely to occur. To verify that these two approaches might be conservative , the containment loads resulting from typical high-pressure accident scenarios (SBO and SBLOCA) for KSNPs were also predicted. The CONTAIN 2.0 calculations with boundary and initial conditions from the MAAP4 predictions, including the sensitivity calculations for DCH phenomenological parameters, have confirmed that the predicted containment pressure and temperature were much below those from these two approaches, and, therefore, DCH issue for KSNPS might be not a problem.

  • PDF

Linearization of T-S Fuzzy Systems and Robust Optimal Control

  • Kim, Min-Chan;Wang, Fa-Guang;Park, Seung-Kyu;Kwak, Gun-Pyong;Yoon, Tae-Sung;Ahn, Ho-Kyun
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.6
    • /
    • pp.702-708
    • /
    • 2010
  • This paper proposes a novel linearization method for Takagi.sugeno (TS) fuzzy model. A T-S fuzzy controller consists of linear controllers based on local linear models and the local linear controllers cannot be designed independently because of overall stability conditions which are usually conservative. To use linear control theories easily for T-S fuzzy system, the linearization of T-S fuzzy model is required. However, The linearization of T-S fuzzy model is difficult to be achieved by using existing linearization methods because fuzzy rules and membership functions are included in T-S fuzzy models. So, a new linearization method is proposed for the T-S fuzzy system based on the idea of T-S fuzzy state transformation. For the T-S fuzzy system linearized with uncertainties, a robust optimal controller with the robustness of sliding model control(SMC) is designed.

Spontaneous Normal Splenic Rupture: A Case Report (젊은 남자 환자에서 발생한 자발적 비장 파열: 증례보고)

  • Lee, Sung Bae;Choi, Young Il
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.208-210
    • /
    • 2014
  • Rupture of the spleen is relatively common, both immediately and in a delayed fashion following significant blunt abdominal trauma. However, atraumatic splenic rupture rarely occurs. Multiple underlying pathologies have been associated with splenic rupture without trauma, including hematological, neoplastic, inflammatory and infectious conditions. In our case, a 21-year-old male without prior medical history visited the hospital with left upper quadrant abdominal pain that had started one day earlier. He had no history of trauma. An abdominal computed tomography (CT) scan found a collection of perisplenic fluid, accompanying a splenic rupture. Due to the patient's stable vital signs and lack of clinical progression of hemorrhage, he underwent conservative treatment. The patient was discharged at day 14 without complication. Rupture of a normal spleen without a history of trauma is not often reported, and it has long been a subject of debate. Ruptures of normal spleen almost always follow some kind of trauma, such as a car accidents or a fall from significant heights. Here, we report a case of spontaneous rupture of a normal spleen in the absence of other medical pathologies or triggering factors.

THE EFFECT OF SOLVENT ACTION OF SODIUM HYPOCHLORITE SOLUTION ON PULP TISSUE (차아염소산(次亞鹽素酸)나트륨용액(溶液)의 치수조직(齒髓組織)에 대(對)한 용해효과(溶解效果))

  • Park, Jin-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.115-121
    • /
    • 1982
  • Sodium hypochlorite solution has been widely used as endodontic irrigant due to its ability to dissolve pulp tissue debris and its antimicrobial action. This in vitro study was conducted to evaluate the solvent action of sodium hypochlorite solution on vital pulp tissue under various conditions include concentration, exposure time, and temperature. The percentage of weight loss due to pulp tissue dissolution was calculated with weight difference of lyophilized specimens before and after the exposure to test solutions. The results were as follows; Statistical analysis indicated that the ability of both 5.0% and 2.5% sodium hypochlorite solutions to dissolve pulp tissue was significantly greater than that of distilled water, but no significant difference was found between 5.0% and 2.5% sodium hypochlorite solutions. There was no significant increase in the pulp tissue dissolving ability of sodium hypochlorite solutions; as exposure time increased 2 minutes, 5 minutes, and 10 minutes. Of the given temperatures, no significant difference was found in the solvent aciton of sodium hypochlorite solution on pulp tissue between $20^{\circ}C$ (room temperature) and $37^{\circ}C$(body temperature).

  • PDF

Analysis of High Burnup Fuel Behavior Under Rod Ejection Accident in the Westinghouse-Designed 950 MWe PWR

  • Chan Bock Lee;Byung Oh Cho
    • Nuclear Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.273-286
    • /
    • 1998
  • As there has arisen a concern that failure of the high burnup fuel under the reactivity-insertion accident(RIA) may occur at the energy lower than the expected, fuel behavior under the rod ejection accident in a typical Westinghouse-designed 950 MWe PWR was analyzed by using the three dimensional nodal transient neutronics code, PANBOX2 and the transient fuel rod performance analysis code, FRAP-T6. Fuel failure criteria versus the burnup was conservatively derived taking into account available test data and the possible fuel failure mechanisms. The high burnup and longer cycle length fuel loading scheme of a peak rod turnup of 68 MWD/kgU was selected for the analysis. Except three dimensional core neutronics calculation, the analysis used the same core conditions and assumptions as the conventional zero dimensional analysis. Results of three dimensional analysis showed that the peak fuel enthalpy during the rod ejection accident is less than one third of that calculated by the conventional zero dimensional analysis methodology and the fraction of fuel failure in the core is less than 4 %. Therefore, it can be said that the current design limit of less than 10 percent fuel failure and maintaining the core coolable geometry would be adequately satisfied under the rod ejection accident, even though the conservative fuel failure criteria derived from the test data are applied.

  • PDF

The Clinical Observation on 3 Cases of Hemifacial Spasm (침술요법과 부항요법을 사용한 안면경련 치험 3례 -근막동통증후군(Myofascial syndrome: MPS)을 위주로 하여 치료함-)

  • Park, Ho-soon;Kim, Yoon-bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.16 no.3
    • /
    • pp.242-251
    • /
    • 2003
  • In the treatment of hemifacial spasm, the operative methods, such as neurovascular decompression, rhizotomy etc. are the most efficacious therapy on its control. But, due to some side effects and complication, pharmacotherapy has been the first attempted by first intention of hemifacial spasm. The carbamazepine is the most commonly used agent, however it is often inefficacious in some cases, and attenuates as the time passes, engages in some symptoms, such as dizziness, nausea, vomiting, and causes an aplastic anemia, it has many deficiencies in becoming the first intention. Acupuncture is a simple, effective and conservative spasm control modality. It is so simple to use in hemifacial spasm. We had observed 3 cases of hemifacial spasm which were treated by acupuncture in Oriental clinic recently. We reported these cases and reviewed related literatures briefly. The results of treatment are as follows; The clinical conditions of spasm intensity was improved after the therapy. These results suggest that acupuncture and negative therapy be effective as the first intention in healing hemifacial spasm.

  • PDF

FATIGUE LIFE ASSESSMENT OF REACTOR COOLANT SYSTEM COMPONENTS BY USING TRANSFER FUNCTIONS OF INTEGRATED FE MODEL

  • Choi, Shin-Beom;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Jhung, Myung-Jo;Choi, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.590-599
    • /
    • 2010
  • Recently, efficient operation and practical management of power plants have become important issues in the nuclear industry. In particular, typical aging parameters such as stress and cumulative usage factor should be determined accurately for continued operation of a nuclear power plant beyond design life. However, most of the major components have been designed via conservative codes based on a 2-D concept, which do not take into account exact boundary conditions and asymmetric geometries. The present paper aims to suggest an effective fatigue evaluation methodology that uses a prototype of the integrated model and its transfer functions. The validity of the integrated 3-D Finite Element (FE) model was proven by comparing the analysis results of individual FE models. Also, mechanical and thermal transfer functions, known as Green's functions, were developed for the integrated model with the standard step input. Finally, the stresses estimated from the transfer functions were compared with those obtained from detailed 3-D FE analyses results at critical locations of the major components. The usefulness of the proposed fatigue evaluation methodology can be maximized by combining it with an on-line monitoring system, and this combination, will enhance the continued operations of old nuclear power plants.

Thermal Analysis Comparison of IMO with USCG Design Condition for the INGC During the Cool-down Period (급냉각기간에서 IMO설계조건과 USCG 설계조건에 대한 LMGC 화물탱크의 열해석 비교)

  • Lee, Jung-Hye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1390-1397
    • /
    • 2004
  • This study is concerned with the thermal analysis during the cool-down period of 135,000㎥ class GT-96 membrane type LNG carrier under IMO and USCG design condition. During the cool-down period, the spraying rate for the NG cooling decreases as the temperature of NG falls down from -4$0^{\circ}C$ to -l3$0^{\circ}C$, and the spraying rate for the cooling of the insulation wall increases as the temperature gradient of the insulation wall is large. It was confirmed that there existed the largest temperature decrease at the first barrier and the first insulation, which are among the insulation wall, especially in the top side of the insulation wall under IMO and USCG design condition. Also, as the NG temperature distribution is fixed, the outer temperature condition under the design condition has influence on the temperature variation at the insulation. By the 3-D numerical calculation about the cargo tank and the cofferdam during the cool-down period, the temperature variation in hulls and insulations is precisely predicted under IMO and USCG design condition. From the comparison between two conditions; IMO design condition shows more severe temperature gradient than USCG design condition, therefore, it provides the conservative estimation of the BOG.

Direct Numerical Simulation of Turbulent Heat Transfer to Fluids at Supercritical Pressure Flowing in Vertical Tubes (직접수치모사를 이용한 수직원형관내 초임계압 유체의 난류 열전달 특성 연구)

  • Bae, Joong-Hun;Yoo, Jung-Yul;Choi, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1302-1314
    • /
    • 2004
  • Turbulent heat transfer to $CO_2$ at supercritical pressure flowing in vertical tubes is investigated using direct numerical simulation (DNS). A conservative space-time discretization scheme for variable-density flows at low Mach numbers is adopted in the present study to treat steep variations of fluid properties at supercritical pressure just above the thermodynamic critical point. The fluid properties at these conditions are obtained using PROPATH and used in the form of tables in the simulations. The buoyancy influence induced by strong variation of density across the pseudo-critical temperature proved to play a major role in turbulent heat transfer at supercritical state. Depending on the degree of buoyancy influence, turbulent heat transfer may be enhanced or significantly deteriorated, resulting in local hot spots along the heated surface. Based on the results of the present DNS combined with theoretical considerations, the physical mechanism of this local heat transfer deterioration is elucidated.