• Title/Summary/Keyword: connection type

Search Result 1,444, Processing Time 0.024 seconds

Large Area Plasma Characteristics using Internal Linear ICP (Inductively Coupled Plasma) Source for the FPD processing

  • Kim, Kyong-Nam;Lim, Jong-Hyeuk;Yeom, Geun-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.544-547
    • /
    • 2006
  • In this study, the characteristics of large area internal linear ICP sources of $1,020mm{\times}920mm$ (substrate area is $880mm{\times}660mm$) were investigated using a multiple linear antennas with U-type parallel connection. Using the multiple linear antennas with U-type parallel connection, a high plasma density of $2{\times}10^{11}/cm^3$ and a high power transfer efficiency of about 88% could be obtained at 5kW of RF power and with 20mTorr Ar. A low plasma potential of less than 26V and a low electron temperature of $2.6{\sim}3.2eV$ could be also obtained. The measured plasma uniformity on the substrate size of 4th generation $(880mm{\times}660mm)$ was about 4%, therefore, it is believed that the multiple linear antennas with U-type parallel connection can be successfully applicable to the large area flat panel display processing.

  • PDF

Precast Shear Wall Systems with C Type Connections (C형 접합부를 이용한 프리캐스트 전단벽 시스템에 관한 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.217-224
    • /
    • 2006
  • This thesis investigates the behavior of precast wall systems with a new vertical connection which are proportioned by the displacement based design. The proposed precast wall systems are supposed to provide additional spaces and seismic strengthening in remodeling existing residential buildings. For a fast remodeling constructions using PC wails require an efficient, economic fabrication method. A C-type vertical connections for PC wall systems is proposed for transfer of bending moment between walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing. The proposed vertical connection allows us easy fabrication because of different direction of slots at the edges of wall. The dimension of C-type connection components are determined by engineering models and a series of test.

  • PDF

Development and Performance Evaluation of the Fourth Generation H-section Beam-to-Column Weak Axis Connection for Improving Workability (시공성 향상을 위한 제4세대 H형강 기둥-보 약축접합부의 개발 및 성능평가)

  • Kim, Pil-Jung;Boo, Yoon-Seob;Yang, Jae-Guen;Lee, Eun-Taik;Kim, Sang-Seup
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.295-304
    • /
    • 2011
  • Bracket-type connection is often used for the weak-axis steel connection. In general, a beam-to-column connection for the bracket type is fabricated at the shop and abeam splice is additionally attached to the bracket in the site. Therefore, steel construction would not be competitive due to the increase of beam splice fabrication cost and overall construction period. This paper now proposes the new weak-axis connection types without a scallop, which has more definite strength flow, simple connection details, and better workability. From the series of experiments, the proposed connections showed better strength and ductility in comparison with standard details with scallop because the thickness of the welding plate for wide-flanged, beam-to-column connection can be easily adjusted.

Cyclic Testing of Bracket and WUF-B Type Weak-Axis Steel Moment Connections (브라켓 및 WUF-B 형식 철골모멘트골조 약축접합부 내진성능평가)

  • Lee, Kang Min;Jeong, Hee Taek;Yoon, Seok Ryong;Lee, Eun Mo;Oh, Kyung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2008
  • There has been much focus on the strong axis steel moment connections after the Northridge earthquake in 1994. However, research studieson the seismic behavior of weak axis moment connections could be hardly found despite the fact that these connection details have been frequently used as seismic details of MRF in Korea. Therefore, the objective of this research is to provide better knowledge on the seismic behavior of weak-axis steel moment connections, which can be widely applicable to many structures with similar characteristics. For this purpose, an experimental program was designed and performed with twotypes of weak-axis steel moment connections, namely the bracket type and WUF-B type, based on the survey of existing field data and literatures. Using the experimental results obtained from the quasi-static cyclic testing of these specimens, structural performances of the joints such as hysteretic curves, maximum strength capacities and the strain of reinforced bars were investigated. From the test results, the bracket-type connection was shown to have more than a 5% story drift capacity, compared with the WUF-B type connection's 4%. These specimens were also shown to have higher strength capacities than the nominal design strength. The bracket-type connection showed a slow strength degradation after maximum strength was researched. However,the WUF-B type connection showed a rapid strength degradation that caused brittle behavior.

A TWO DIMENSIONAL STRESS ANALYSIS OF FIXED PROSTHESIS WITH OSSEOINTEGRATED IMPLANT AS AN INTERMEDIATE ABUTMENT (골유착성 임플란트를 중간 지대치로 사용한 고정성 보철물의 응력분석)

  • Park Sang-Soo;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.611-624
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution of the natural teeth, the implant, the prosthesis and the supporting tissue according to the types of implant and connection modality in the five-unit fixed partial denture with a implant pier abutment. A Two dimensional stress analysis model was constructed to represent a mandible missing the first and second premolars and first molar. The model contained a canine and second molar as abutment teeth and implant pier abutments with and without stress-absorbing element. Finite element models were created and analyzed using software ANSYS 4.4A for IBM 32bit personal computer. The results obtained were as follows. 1. Implant group, compared to the natural teeth group, showed a maximum principal stress at the superior portion of implants and a stress concentration at :he neck and end portion. 2. Maximum principal stress and maximum Von Mises stress were always lower in the case of rigid connection than nonrigid connection. 3. A cylinder type implant with stress absorbing element and screw type implant were generally similar in the stress distribution pattern. 4. A screw type implant, compared to the cylinder type implant, showed a relatively higher stress concentration at both neck and end portion of it. 5. Load B cases showed higher stress concentration on the posterior abutments in the case of nonrigid connector than rigid connector. 6. A maximum displacement was always lower in the case of rigid connection than nonrigid connection. These results suggest that osseointegrated implant can be used as an intermediate abutment.

  • PDF

A Basic Study on Connectivity of Urban Parks for the Urban Ecological Network Establishment (도시생태네트워크 구축을 위한 도시공원의 연결성 평가 기초 연구)

  • Sung, Hyun-Chan;Kim, Mi-Ri;Hwang, So-Young;Kim, Su-Ryeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.2
    • /
    • pp.125-136
    • /
    • 2014
  • Urban Green Area has ecologically deteriorated along with quantitative loss, being developed as a dot itself rather than connected to forests and green networks around the park. The present study aims to propose a connected plan on Urban Ecological Network establishment through 'assessment of the connectivity of the entire urban parks' in accordance with distance of forest and river and 'assessment of trends in connection fragmentation of urban parks' in accordance with the past change of forest and river. According to the result of this study, criteria based on previous research was "directly linked type is less than 300m, conceptually linked type is between 300m to 1km, the isolated type is greater than 1km". And the result of 'assessment of the connectivity of the entire urban parks' is analyzed as the rate of park and green network, 41.7% in Suwon, 80.0% in Seongnam, 88.9% in Namyangju on the basis of office and field investigation. Also, according to the result of 'assessment of trends in connection fragmentation of urban parks', consideration for connection to the original forest is insufficient.

Reliabilities of distances describing bolt placement for high strength steel connections

  • Oztekin, Ertekin
    • Structural Engineering and Mechanics
    • /
    • v.54 no.1
    • /
    • pp.149-168
    • /
    • 2015
  • In the bolted connections, bolt placements are generally described and are generally made in the direction of design effects and in the perpendicular direction to design effects. In these both directions, the reliability of the distance of bolts to the edges of connection plate and the distance of bolts to each other is investigated for high strength steel connections built up with high strength bolts in this study. For this purpose, simple SL (bearing type shear connection) and SLP (bearing type shear connection for body-fit bolts) type steel connections with St 52 grade steel plates with 8 different thicknesses and with 8.8D grade high strength bolts (HV) were constituted and analyzed under H (Dead Loads+Live Loads+Snow Loads+Roof Loads) and HZ (H Loads+Wind Loads+Earthquake Loads) loadings. Geometric properties, material properties and design actions were taken as random variables. Monte Carlo Simulation method was used to compute failure risk and the first order second moment method was used to determine the reliability indexes of those different distances describing the placement of bolts. Results obtained from computations have been presented in graphics and in a Table. Then, they were compared with some values proposed by some structural codes. Finally, new equations were constituted for minimum and maximum values of distances describing bolt placement by regression analyses performed on those results.

A Study on Safe Permanent Joint Type Multiple Socket-Outlets Development without Soldering Crimped Connection (안전형 비납땜 틀고정 영구 접속형 멀티콘센트 개발에 관한 연구)

  • Cho, Won-Seok;Lee, Wi-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.47-54
    • /
    • 2015
  • Normally, multiple socket-outlet is manufactured with soldered, welded permanent connection (termination). Because this procedure is very non-environmental and requires many labor forces, many companies skip this process. To solve this these problems, this research had to design permanent joint type multiple socket-outlet, develop safer multiple socket-outlet than is sold in markets. Progressing this research, we took 3 steps. First, we had to design device for fixing a frame suitable for multiple socket-outlet. Second, this multiple socket-outlet must pass fundamental standards through international standard (IEC 60884-1) and Korean standard (K 60884-1) tests. Third, it had to pass both several mechanical and electrical tests which is more strict than fundamental standards and vibration and impact tests following KS standards for enhancing its safety. After finishing 3 steps, we could obtain objective and fair data, develop environmental permanent joint type multiple socket-outlet without soldering crimped connection.

The Effect of Construction Methods on Geothermal Exchange Rates of Cast-in-place Energy Piles (현장타설말뚝형 에너지 파일의 시공형태별 지중 열교환량에 관한 연구)

  • Park, Yong-Boo;Nam, Yu-Jin;Sim, Young-Jong;Sohn, Jeong-Rak
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.169-175
    • /
    • 2012
  • In recent, there are many studies associated with energy piles to save initial construction cost for ground source heat pump system. In this study, to evaluate geothermal exchange rates two types (a connection type and a slinky type) of cast-in-place energy piles (PRD, 4.5m in depth, 1,200 mm in diameter) were constructed for the tests and their efficiencies were compared with numerical analysis results. As a result, starting with operation, geothermal exchange rate gradually decreases due to exchange of lower ground temperature. In the case of connection type, temperature difference is $0.37^{\circ}C$ in heating mode and $0.34^{\circ}C$, in cooling mode, respectively. In addition, in case of a connection type, geothermal exchange rate in heating mode is 2,314W/m and in cooling mode, 252.2W/m whose value is 9% higher than in heating mode. In the case of slinky type, the average geothermal exchange rate in heating mode is 168.0W/m, which is about 27% lower than that of connection type.

Development of Wide Connection Method for Vertical Joints of Precast Concrete Walls (프리캐스트 콘크리트 벽체 수직접합부의 광폭형 연결방식 개발)

  • Choi, Eun-Gyu;Shin, Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.549-556
    • /
    • 2009
  • This research analyzed the structural efficiency and application by improving the 100 mm width vertical joint to 150 mm and developing three connection methods to reduce the difficulty in assembling and handling PC walls. Moreover, nonlinear finite analysis was used for analyzing. From the analysis results, when double width connection was applied, the PC wall showed larger load capacity and ductility due to the steel bar sharing loads efficiently. Moreover, as the dimension of loops and the number of bars increased, the maximum load capacity increased as well. Also, among the double width connections, the largest capacity showed in the order of welding, ring and C type loop. However, in case of welding type loop connection, the ring type loop is more stable due to changes in different site conditions. Therefore, thorough quality control of welding is necessary.