• 제목/요약/키워드: connection type

검색결과 1,446건 처리시간 0.026초

IONIZED GAS KINEMATICS ALONG THE RADIO JET IN TYPE 2 AGNS

  • LE, HUYNH ANH N.;WOO, JONG-HAK;SON, DONGHOON
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.51.3-51.3
    • /
    • 2017
  • To investigate the connection between radio activity and AGN outflows, we present a study of ionized gas kinematics by using [O III] ${\lambda}5007$ emission line along the radio jet for six radio AGNs. These AGNs are selected based on the radioactivity (L1.4GHz ${\geq}$ 1039.8 erg s-1) as well as optical properties as type 2 AGNs. By using the high spatial resolution of the Red Channel Cross Dispersed Echellette Spectrograph at the Multiple Mirror Telescope, we investigate in detail the [O III] and stellar kinematics. We spatially resolve and probe the central AGN-photoionization sizes, which is important in understanding the structures and evolutions of galaxies. We find that the typical central AGN-photoionization sizes of our targets are in range of 1.8-3.8 kpc. We study the [O III] kinematics along the radio jets to test whether there is a link between gas outflows in the narrow-line region and radio jet emissions. Contrary to our expectation, we find no evidence that the gas outflows are directly connected to radio jet emission.

  • PDF

Numerical parametric analysis on the ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips

  • Zhang, Yingying;Song, Xiaoguang;Zhang, Qilin
    • Structural Engineering and Mechanics
    • /
    • 제63권2호
    • /
    • pp.195-206
    • /
    • 2017
  • This paper presents the parametric numerical analysis on the ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips. The effects of several factors on failure modes and ultimate bearing capacity of the purlins are studied, including setup of anti-sag bar, purlin type, sheet thickness and connection type et al. A simplified design formula is proposed for predicting the ultimate bearing capacity of purlins. Results show that setting the anti-sag bars can improve the ultimate bearing capacity and change the failure modes of C purlins significantly. The failure modes and ultimate bearing capacity of C purlins are significantly different from those of Z purlins, in the purlin-sheet roof connected by standing seam clips. Setting the anti-sag bars near the lower flange is more favorable for increasing the ultimate bearing capacity of purlins. The ultimate bearing capacity of C purlins increases slightly with sheet thickness increasing from 0.6 mm to 0.8 mm. The ultimate bearing capacity of the purlin-sheet roofs connected by standing seam clips is always higher than those by self-drilling screws. The predictions of the proposed design formulas are relatively in good agreement with those of EN 1993-1-3: 2006, compared with GB 50018-2002.

Design of an Asymmetrical Three-phase Inverter for Load Balancing and Power Factor Correction Based on Power Analysis

  • Mokhtari, M.;Golshannavaz, S.;Nazarpour, D.;Aminifar, F.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.293-301
    • /
    • 2011
  • This paper presents a novel theoretical method based on power analysis to obtain voltage reference values for an inverter-based compensator. This type of compensator, which is installed in parallel with the load, is usually referred to as the active filter. The proposed method is tailored to design the compensator in such a way that it can simultaneously balance the asymmetric load, as well as correct the power factor of the supply side. For clarity, a static compensator is first considered and a recursive algorithm is utilized to calculate the reactance values. The algorithm is then extended to calculate voltage reference values when the compensator is inverter based. It is evident that the compensator would be asymmetric since the load is unbalanced. The salient feature associated with the proposed method is that the circuit representation of system load is not required and that the load is recognized just by its active and reactive consumptions. Hence, the type and connection of load do not matter. The validity and performance of the new approach are analyzed via a numerical example, and the obtained results are thoroughly discussed.

다양한 관절 구성을 위한 모듈라 매니퓰레이터의 관절 및 링크 모듈 형상 도출 (Joint and Link Module Geometric Shapes of Modular Manipulator for Various Joint Configurations)

  • 홍성훈;이우섭;이형철;강성철
    • 로봇학회논문지
    • /
    • 제11권3호
    • /
    • pp.163-171
    • /
    • 2016
  • A modular manipulator in serial-chain structure usually consists of a series of modularized revolute joint and link modules. The geometric shapes of these modules affect the number of possible configurations of modular manipulator after assembly. Therefore, it is important to design the geometry of the joint and link modules that allow various configurations of the manipulators with minimal set of modules. In this paper, a new 1-DoF(degree of freedom) joint module and simple link modules are designed based on a methodology of joint configurations using a series of Rotational(type-R) and Twist(type-T) joints. Two of the joint modules can be directly connected so that two types of 2-DoFs joints could be assembled without a link module between them. The proposed geometries of joint and link modules expand the possible configurations of assembled modular manipulators compared to existing ones. Modular manipulator system of this research can be a cornerstone of user-centered markets with various solution but low-cost, compared to conventional manipulators of fixed-configurations determined by the provider.

동일 병렬 저항을 이용한 초전도 저항형 한류소자 직렬연결방안 및 전압용량 증대 (Increase of the Voltage Rating of Resistive Type Superconducting Fault Current Limiter Using Equal Shunt Resistors)

  • 차상도;김혜림;심정욱;한용희;현옥배
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권7호
    • /
    • pp.327-334
    • /
    • 2003
  • We have investigated the quench behavior of the series connection of resistive type superconducting fault current limiter (SFCL) components based on YBCO films. Equal shunt resistors $R_s$ across individual SFCL components successfully produced simultaneous Quenches for 5 components in series, resulting in equal application of voltage to all components. If the two components having the highest and the lowest critical currents ($I_c$) quench safely, others quench altogether The highest shunt resistance is to guarantee the safe quenches of all components, leading to the equal voltage applications within the first half cycle after a fault in the short circuit test. The highest $R_s$ was found to be 28 [$\Omega$] for the components in the given quench environment. Considering the safe quenches and protection coordination, the optimal $R_s$ was suggested to be approximately a half of the highest $R_s$,, allowing wide selection of $R_s$ and $I_c$'s. This design provides a practical wav of connecting small SFCL components in series for high voltage application.

Seismic performance of single pier skewed bridges with different pier-deck connections

  • Attarchiana, Nahid;Kalantari, Afshin;Moghadam, Abdolreza S.
    • Earthquakes and Structures
    • /
    • 제10권6호
    • /
    • pp.1467-1486
    • /
    • 2016
  • This research focuses on seismic performance of a class of single pier skewed bridges with three different pier-deck connections; skew angles vary from $0^{\circ}$ to $60^{\circ}$. A well-documented four span continuous deck bridge has been modeled and verified. Seat-type connections with fixed and sliding bearings plus monolithic pier-deck connections are studied. Shear keys are considered either fully operational or ineffective. Seismic performances of the bridges and the structural components are investigated conducting bidirectional nonlinear time history analysis in OpenSees. Several global and intermediate engineering demand parameters (EDP) have been studied. On the basis of results, the values of demand parameters of skewed bridges, such as displacement and rotation of the deck plus plastic deformation and torsional demand of the piers, increase as the skew angle increases. In order to eliminate the deck collapse probability, the threshold skew angle is considered as $30^{\circ}$ in seat-type bridges. For bridges with skew angles greater than $30^{\circ}$, monolithic pier-deck connections should be applied. The functionality of shear keys is critical in preventing large displacements in the bearings. Pinned piers experience considerable ductility demand at the bottom.

에너지법에 의한 선체판의 기하학적 비선형거동에 관한 연구 (A Study on the Geometric Nonlinear Behaviour of Ship Plate by Energy Method)

  • 고재용
    • 대한조선학회논문집
    • /
    • 제36권2호
    • /
    • pp.94-104
    • /
    • 1999
  • 고장력강을 주로 사용하는 선체에서 좌굴은 중요한 설계기준이 된다. 판부재는 주로 면내강성을 갖는다. 만약 2차좌굴로 인하여 선체판의 면내강성이 저하한다면 선박전체의 종강도는 크게 저하한다. 그러므로, 판부재의 좌굴후거동과 같은 기하학적 비선형거동을 정확히 규명하여야 하는 것은 구조물 전체적으로 매우 필요하다. 이상과 같은 관점에서 본 논문에서는 에너지법을 이용하여 압축하중을 받는 단순지지판의 기하학적 비선형거동을 규명하였다. 에너지 법을 바탕으로 선체판의 탄성대변형해석을 수행하였고 분기점형좌굴과 극한점형좌굴에 대하여 규명하였다.

  • PDF

A Study of AGN Population in Compact Groups of Galaxies

  • 손주비;황호성;이명균;이광호;이종철
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.37.1-37.1
    • /
    • 2013
  • We present a result of a statistical studies on nuclear activities of compact group galaxies. It is suggested that the galaxy interaction can trigger the nuclear activity by producing the gas inflow to the center of galaxies. To understand the connection between galaxy interaction and nuclear activity, we study the fraction of Active Galactic Nuclei (AGN) host galaxies in compact groups, known as the most favored environment for galaxy interaction. We select 59 spectroscopically confirmed compact groups in the SDSS DR6. Using the emission line ratio, we determine the spectral types of compact group galaxies and obtain the fraction of AGN-host galaxies. We compare this fraction with those in other galaxy environments. For the early type galaxies, we find that the AGN fraction of compact group galaxies are lower than field galaxies, but higher than cluster galaxies. On the other hand, the AGN fraction of compact group galaxies is similar to those for field and cluster environment for the late type galaxies. Implications of this result will be discussed.

  • PDF

단상전원에 접속된 3상 유도전동기의 손실분석 (Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source)

  • 김도진;좌종근
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.

Structural repairing of damaged reinforced concrete beam-column assemblies with CFRPs

  • Yurdakul, Ozgur;Avsar, Ozgur
    • Structural Engineering and Mechanics
    • /
    • 제54권3호
    • /
    • pp.521-543
    • /
    • 2015
  • Depending on the damage type as well as the level of damage observed after the earthquake, certain measures should be taken for the damaged buildings. In this study, structural repairing of two different types of damaged RC beam-column assembly by carbon fiber-reinforced polymer sheets is investigated in detail as a member repairing technique. Two types of 1:1 scale test specimens, which represent the exterior RC beam-column connection taken from inflection points of the frame, are utilized. The first specimen is designed according to the current Turkish Earthquake Code, whereas the second one represents a deficient RC beam-column assembly. Both of the specimens were subjected to cyclic quasistatic loading in the laboratory and different levels of structural damage were observed. The first specimen displayed a ductile response with the damage concentrated in the beam. However, in the second specimen, the beam-column joint was severely damaged while the rest of the members did not attain their capacities. Depending on the damage type of the specimens, the damaged members were repaired by CFRP wrapping with different configurations. After testing the repaired specimens, it is found that former capacities of the damaged members were mostly recovered by the application of CFRPs on the damaged members.