• Title/Summary/Keyword: connection type

검색결과 1,444건 처리시간 0.028초

STUDY OF GRADIENT SOLITONS IN THREE DIMENSIONAL RIEMANNIAN MANIFOLDS

  • Biswas, Gour Gopal;De, Uday Chand
    • 대한수학회논문집
    • /
    • 제37권3호
    • /
    • pp.825-837
    • /
    • 2022
  • We characterize a three-dimensional Riemannian manifold endowed with a type of semi-symmetric metric P-connection. At first, it is proven that if the metric of such a manifold is a gradient m-quasi-Einstein metric, then either the gradient of the potential function 𝜓 is collinear with the vector field P or, λ = -(m + 2) and the manifold is of constant sectional curvature -1, provided P𝜓 ≠ m. Next, it is shown that if the metric of the manifold under consideration is a gradient 𝜌-Einstein soliton, then the gradient of the potential function is collinear with the vector field P. Also, we prove that if the metric of a 3-dimensional manifold with semi-symmetric metric P-connection is a gradient 𝜔-Ricci soliton, then the manifold is of constant sectional curvature -1 and λ + 𝜇 = -2. Finally, we consider an example to verify our results.

CFT 각형 기둥-보 합성 반강접 접합부의 단조가력 실험 (Monotonic Loading Test for CFT Square Column-to-Beam Partially Restrained Composite Connection)

  • 최성모;박수희;박영욱;김진호
    • 한국강구조학회 논문집
    • /
    • 제17권3호통권76호
    • /
    • pp.325-335
    • /
    • 2005
  • 본 연구의 목적은 CFT각형기둥과의 접합에 성능이 개선된 합성 반강접 접합디테일을 제안하고 기둥-보 접합부의 단조가력시 역학적 거동을 보기 위함이다. 극한 거동에 결정적 영향을 끼치는 하부 접합부의 전단내력을 보강하고 시공성을 고려하여 합성 반강접 접합을 CFT구조 형식에 시도하여 CFT기둥-보 접합부의 접합디테일을 제안하였다. 본 연구에서 제안하는 하부 보 플랜지 용접접합(M-2)을 기존 합성 반강접 접합상세인 시트앵글접합(M-1)과 비교/검토하였다. 두 개의 실대형 CFT기둥-보 합성 반강접 접합부 실험체에 대한 단조가력실험을 수행하였다. 실험 결과, 제안형인 하부 보플랜지 용접접합된 실험체는 강접합된 철골보의 약 85%의 강성을 확보하였다. 이는 기존형 실험체와 거의 동일하였으며, 반강접으로 분류됨을 확인할 수 있었다. 제안형 실험체가 웨브 접합부에서 볼트지압에 의한 전단파괴가 발생하였으나 파단 직전까지는 슬래브 연성파괴가 일어난 기존형 실험체와 유사한 거동을 보였다. 슬래브 보강근에 의해 충분한 강성 및 내력이 확보되며, 웨브부분의 강관내의 앵커보강에 의해 전소성모멘트에 상응하는 내력 및 변형성능이 확보되어 충분한 연성거동을 보이는 것으로 판단된다.

직각판형 외다이아프램 각형강관기둥-H형강보 접합부의 방강접거동에 관한 해석적연구 (A Numerical Study on the Semi-Rigid Behavior of Steel Tubular Column to H Beam Connection with Exterior Square-Plate Diaphragms)

  • 채용수;최성모;김동규
    • 한국강구조학회 논문집
    • /
    • 제13권3호
    • /
    • pp.289-299
    • /
    • 2001
  • 본 논문은 직각펀형 외다이아프램 형식의 각형강관-H형강보 접합부의 반강접 특성을 파악하기 위하여 기존 실험결과를 수집하여 모든 실험체를 기준이 되는 실험방법과 동일하게 모델링하여 유한요소해석을 실시하였다. 이 해석결과를 실험결과와 비교 검증하여 해석결과의 신뢰성을확보, 이를 준용하는 것으로 하여 본 접합부형식의 반강접거동에 영향을 미치는 주요한 변수를 파악하고 차후 골조해석에 적용 가능한 적절한 모멘트-회전각 곡선을 제안, 함수를 구성하는 세가지 파라메타에 대하여 다중선형회귀분석을 실사하였다.

  • PDF

해상 운송 플랜트 구조물의 고장력 볼트 피로성능 평가 (Fatigue Performance Evaluation of High-strength Bolt Used for Marine Transport Plant Structures)

  • 소재혁;오근영;박관식;김선우;이강민
    • 한국강구조학회 논문집
    • /
    • 제29권1호
    • /
    • pp.89-98
    • /
    • 2017
  • 해양플랜트 구조물은 현장에서의 제작이 어려워 작업장에서 중 소단위의 모듈로 제작한 뒤 바지선을 이용해 현장으로 운송 후 설치 제작하는 방식이 사용되고 있다. 이 때 운송 시 발생하는 반복적인 환경하중으로 인해 구조물의 접합부에 피로하중이 작용하게 된다. 따라서 본 연구에서는 플랜트구조물의 운송과정에서 발생하는 피로하중을 적용한 고장력 볼트 접합부의 피로강도에 대한 구조적 신뢰성을 확인하고자 도입축력, 마찰계수, 볼트종류를 변수로 한 실험연구를 수행하였다. 다양한 변수를 고려한 고장력 볼트의 축력변화에 따른 볼트 풀림 현상 규명 연구결과, 고장력 볼트의 축력변화가 1% 내외에서 나타나 구조적 안전성에는 영향을 미치지 않는 것으로 판단된다.

해저철도터널(목포-제주간) 화재시 정량적 위험도 평가기법에 의한 피난연결통로 적정간격산정에 관한 연구 (The study on interval calculation of cross passage in undersea tunnel by quantitative risk assesment method)

  • 유지오;김진수;이동호;신현준
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.249-256
    • /
    • 2015
  • 현재 목포-제주간 해저터널은 타당성 검토를 위한 기본계획 중에 있으며, 노선의 길이가 108 km인 고속여객 전용선으로 단면형태는 유로터널과 같은 서비스터널을 설치한 단선쌍굴터널로 검토되고 있다. 또한 교통량은 10량 1편성의 열차가 일일 76편/편도 운행하는 것으로 계획하고 있다. 이에 본 연구에서는 터널의 피난연결통로의 적정 간격을 정량적 위험도 평가기법에 의해서 검토하는 것을 목표로 정량적 위험도 평가기법을 정립하였다. 또한 터널의 단면형태를 복선터널(Type 3), 쌍굴터널(Type 1) 및 복선터널을 격벽으로 분리하는 형태의 터널(Type 2)을 대상으로 단면형태별로 적정 피난연결통로 간격을 산정하였다. 본 연구결과, Type 2의 단면이 대피안전확보에 가장 효과적이며, 현행 국내 사회적 위험도 평가기준을 만족하기 위해서는 단면형태별로 350 m (Type 1), 400 m (Type 2), 1,500 m (Type 3)의 피난연결통로 간격이 요구되는 것으로 나타나고 있다.

총폐정맥 이상환류증의 수술요 (Surgical correction of total anomalous pulmonary venous connection)

  • 김기봉;노준량
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.48-52
    • /
    • 1984
  • Total anomalous pulmonary venous connection [TAPVC] defines a group of congenital heart disease which have in common the entire pulmonary venous drainage returning directly or indirectly to the right atrium instead of to the left atrium. Although this disorder represents only 1.3% of cases of congenital heart disease, if untreated the resultant mortality is greater than 80% in the 1st year of life. And since there is no satisfactory palliative treatment, correction of TAPVC Is high on the list of indications for open heart surgery in the 1st year of life. This paper describes 10 patients who underwent surgical correction of this disorder at SNUH between 1978 and 1983. 1. 7 were males and 3 females, with ages ranging from 5 months to 24 years. 2. 7 were supracardiac type, 2 cardiac type, and 1 mixed type TAPVC. We didnt experience infracardiac type. 3. All showed some degree of pulmonary hypertension preoperatively. 4. In 4 cases of supracardiac type, total circulatory arrest was used in brief period during anastomosis between common pulmonary venous trunk and left atrium. In the other cases, usual cardiopulmonary bypass with moderate to deep hyperthermia was used. 5. There were 2 cases of mortality; 1 died at operation, and the other at 4 months due to congestive heart failure. 6. Mortality seemed not closely related to age, body weight, or severity of pulmonary hypertension.

  • PDF

Type IV 고세장비 모듈형 수소저장용기의 충전 조건에서의 수치해석적 연구 (A Numerical Analysis Study on Charging Conditions of Type IV High Aspect Ratio Modular Hydrogen Storage Vessel)

  • 백중택;문지훈;민지훈;박균범;기광택;주성욱
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.26-31
    • /
    • 2023
  • In this study, in order to propose a modular method for type IV high aspect ratio modular hydrogen storage vessel, a numerical analysis was conducted on the heat transfer behavior in series and parallel connection methods, and the differences according to each connection method were reviewed. Computational fluid dynamics software was used to check the internal temperature and pressure values of the hydrogen storage container under charging conditions. In terms of thermal safety when charging hydrogen gas, it was confirmed that the parallel modularization method was superior.

SYMMETRIC IDENTITIES FOR DEGENERATE CARLITZ-TYPE q-EULER NUMBERS AND POLYNOMIALS

  • RYOO, CHEON SEOUNG
    • Journal of applied mathematics & informatics
    • /
    • 제37권3_4호
    • /
    • pp.259-270
    • /
    • 2019
  • In this paper we define the degenerate Carlitz-type q-Euler polynomials by generalizing the degenerate Euler numbers and polynomials, degenerate Carlitz-type Euler numbers and polynomials. We also give some interesting properties, explicit formulas, a connection with degenerate Carlitz-type q-Euler numbers and polynomials.

SOME PROPERTIES OF DEGENERATE CARLITZ-TYPE TWISTED q-EULER NUMBERS AND POLYNOMIALS

  • RYOO, CHEON SEOUNG
    • Journal of applied mathematics & informatics
    • /
    • 제39권1_2호
    • /
    • pp.1-11
    • /
    • 2021
  • In this paper, we define degenerate Carlitz-type twisted q-Euler numbers and polynomials by generalizing the degenerate Euler numbers and polynomials, Carlitz's type degenerate q-Euler numbers and polynomials. We also give some interesting properties, explicit formulas, symmetric properties, a connection with degenerate Carlitz-type twisted q-Euler numbers and polynomials.

내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구 (FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM)

  • 이흥태;정재헌
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.