Impedance-based damage monitoring of steel column connection: numerical simulation

  • Ho, Duc-Duy;Ngo, Thanh-Mong;Kim, Jeong-Tae
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.3
    • /
    • pp.339-356
    • /
    • 2014
  • This study has been motivated to evaluate the practicality of numerical simulation of impedance monitoring for damage detection in steel column connection. In order to achieve the objective, the following approaches are implemented. Firstly, the theory of electro-mechanical (E/M) impedance responses and impedance-based damage monitoring method are outlined. Secondly, the feasibility of numerical simulation of impedance monitoring is verified for several pre-published experimental examples on steel beams, cracked aluminum beams, and aluminum round plates. Undamaged and damaged steel and aluminum beams are simulated to compare to experimental impedance responses. An aluminum round plate with PZT patch in center is simulated to investigate sensitive range of impedance responses. Finally, numerical simulation of the impedance-based damage monitoring is performed for a steel column connection in which connection bolts are damaged. From the numerical simulation test, the applicability of the impedance-based monitoring to the target steel column connection can be evaluated.

Development of Hybrid FRP-Concrete Composite Pile Connection (하이브리드 FRP-Concrete 복합말뚝의 연결부의 개발)

  • Lee, Hyoung-Kyu;Park, Joon-Seok
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.4
    • /
    • pp.52-57
    • /
    • 2014
  • Due to the advantageous mechanical properties of the fiber reinforced polymeric plastics(FRP), their application in the construction industries is ever increasing trend, as a substitute of structural steel which is highly vulnerable under hazardous environmental conditions (i.e., corrosion, humidity, etc.). In this study, hybrid FRP-concrete composite pile (HCFFT) connection is suggested. The HCFFT is consisted of pultruded FRP unit module, filament wound FRP which is in the outside of mandrel composed of circular shaped assembly of pultruded FRP unit modules, and concrete which is casted inside of the circular tube shaped hybrid FRP pile. Therefore, pultruded FRP can increase the flexural load carrying capacity, filament wound FRP and concrete filled inside can increase axial load carrying capacity. In the study, connection capacity of HCFFT(small and mid size) is investigated throughout experiments and finite element method. From the results of experiments, we suggested the connection methods about HCFFT pile connection.

Evaluation of Pavement Rehabilitation Using Precast Concrete Slabs and Slab Connection methods (보수용 조립식 콘크리트 포장 적용성 및 슬래브 접합 방식 분석)

  • Cho, Young-Kyo;Oh, Han-Jin;Hwang, Ju-Hwan;Kim, Seong-Min;Park, Sung-Ki
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.165-174
    • /
    • 2010
  • This study was conducted to evaluate the feasibility of expedite repairing of concrete pavements using precast concrete pavement method and to investigate the effectiveness of slab connection methods. In the demonstration construction, four slabs of jointed concrete pavements were replaced with the precast slabs. First, precast concrete slabs were designed and fabricated, then existing slabs were cut and removed, and finally precast slabs were installed. The slabs were leveled and pockets, holes, and space between the slab bottom and the underlying layer were grouted. From the demonstration construction, details about the design and construction of the precast pavements for repairing of pavements were evaluated. In addition, the slab connection methods such as pocket and hole connection methods were applied in the construction and the slab curling behaviors at the joints that include those connection methods were compared. The results showed that both slab connection methods were applicable, and the hole connection method was superior.

Strength of Interior Plat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부의 강도산정모델)

  • 최경규;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.961-972
    • /
    • 2002
  • Flat plate structures under lateral load are susceptible to the brittle shear failure of plate-column connection. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, according to previous studies, current design methods do not accurately estimate the strength of plate-column connection. In the present study, parametric study using nonlinear finite element analysis was performed for interior connections. Based on the numerical results, a design method for the connection was developed. At the critical sections around the connection coexist flexural moment and shear developed by lateral and gravity loads, and maximum allowable eccentric shear stresses were proposed based on the interactions between the flexural moment and shear, The proposed method can precisely predict the strength of the connection, compared with the current design provisions. The predictability of the proposed method was verified by the comparisons with existing experiments and nonlinear numerical analyses.

Experimental Test on Coner Rigid Joint Connection Method for Underground Roadway Structure (지하차도 구조물의 우각부 연결장치에 대한 실험적 평가)

  • Kim, Sung Bae;Kim, Jang Ho Jay;Kim, Tae Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.23-34
    • /
    • 2013
  • In this study, a safe, economic, and rapid construction method of underground roadway using PSC girder is developed to reduce traffic congestion and maximize space usage in urban area. For an efficient application of the method, a rigid joint connection is proposed and tested. For the testing, cantilever specimens were used to verify its capacity. The parameters for this study were cross beam length and joint connection type. The results of the test showed that the proposed connection system has superior performances. Despite having differences of cross beam length and joint connection type, the stable flexural behavior was shown in all of the tested specimens. Also, the behaviors of PSC girders and upper slabs connected by the proposed method showed superior performance. Moreover, the improvement of structure performance according to the increase of length of cross beams has been verified.

Design of Filter Cut-off Technology based on Directshow (다이렉트쇼 기반의 필터차단기술 설계)

  • Kim, Dae-Jin;Choi, Hong-Sub
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.77-85
    • /
    • 2009
  • As the multimedia technology has become in popular, many software packages that are for using those multimedia contents have also been developed. Directshow is a media framework which makes the development of such multimedia software simple, quick and regular process. In the Directshow, data are processed through the connections between filters. In general, Filtergraph is utilized to be set as 'Intelligent Connection' for filter connection. However, when we use this 'Intelligent Connection' option, they can show non-expected results or fail to connect with filter's pins together. So in this paper, we propose non-necessary filter cut-off method for connecting only just wanted filters. There are two methods such as inner filter cut-off method and outer filter one. The inner filter cut-off method is good at connection's compatibility and able to quickly connect with each other filter. But in the outer filter cut-off method, filter source is not necessary and connection is exactly done with other filter. In the end, we propose Directshow based filter cut-off model which compose of wanted filter connection and minimize error probability, through mixing up the advantages of two filter cut-off methods.

Constructability Analysis of Green Columns at the Low Bending Moment Zone

  • Lee, Sung-Ho;Park, Jun-Young;Lim, Chae-Yeon;Kim, Sun-Kuk
    • Journal of Construction Engineering and Project Management
    • /
    • v.3 no.4
    • /
    • pp.12-19
    • /
    • 2013
  • Green Frame is an environmentally friendly column-beam system composed of composite PC members that can increase buildings' life spans while reducing resource consumption. Typically, connections of PC and RC columns occur at the boundaries of each floor, which is at the upper section of slabs, causing the boundary of each floor to generate the maximum moment. Although it is not optimal in terms of structural safety to connect members at a location where the moment is high, this approach is highly adopted due to its constructability. We propose that a superior approach that employs the concept of connecting columns at the low bending moment zone can be applied to quickly and safely install green columns, the main structural members of Green Frame. Connection of green columns at the low bending moment zone can be classified into three techniques, depending on the method of reinforcing the joints, which have different connection characteristics and construction methods. Research is needed to compare the features of each method of reinforcing the joints so that the most appropriate column connection method can be chosen for the site conditions. This study aims to confirm the structural safety of the connection component at the low bending moment zone and to compare and analyze the construction duration, unit price, quality and safety performance of each column connection method. The study results are anticipated to activate the use of composite precast concrete and to be used as development data in the future.

A study of Multiple parallel Characteristics of 50[W] Virtual Implement of 50[W] Solar Cell modules Using Droop-Method (Droop Method를 이용한 50[W]급 태양전지 가상구현장치의 다중병렬연결 출력특성에 관한 연구)

  • Lee Byung-In;Lee Sang-Yong;Jung Byung-Hwan;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.81-84
    • /
    • 2003
  • For increasing power of photovoltaic systems, serial and parallel connection needed. In parallel connection, a desirable characteristic of parallel-connected supply system is that individual converters share the load current equally and stably. The current sharing(CS) can be implemented using two approaches. The first one, known as a Droop method, and the other is Active current-sharing. In Droop method, current distribution characteristics relies on the high output impedance of each converter. This scheme is more simple and no need interconnections. but also has a disadvantages of degrading current sharing characteristics. In this paper, using droop method at multiful-parallel connection with it's convenience and simplicity.

  • PDF

Explicit Rate Allocation Algorithsm using the Connection Setup Information in ATM Networks (ATM 망에서 호 설정 정보를 이용한 명시적 전송률 할당 알고리즘)

  • 김대일;김중민;박인갑
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.379-382
    • /
    • 2001
  • In this paper, a new enhanced early fair rate allocation(EFRA+) algorithm is proposed for ATM switches supporting ABR service. The central issue of explicit rate control algorithms for ABR service is the computation of max-min fair rates for every connection. The EFRA+ inherits the main feature of the EFRA, uses the connection control information during the connection setup to prevent potential congestion in switches, and enhances the computation method of the max-min fair rate.

  • PDF

A study on skip-connection with time-frequency self-attention for improving speech enhancement based on complex-valued spectrum (복소 스펙트럼 기반 음성 향상의 성능 향상을 위한 time-frequency self-attention 기반 skip-connection 기법 연구)

  • Jaehee Jung;Wooil Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.94-101
    • /
    • 2023
  • A deep neural network composed of encoders and decoders, such as U-Net, used for speech enhancement, concatenates the encoder to the decoder through skip-connection. Skip-connection helps reconstruct the enhanced spectrum and complement the lost information. The features of the encoder and the decoder connected by the skip-connection are incompatible with each other. In this paper, for complex-valued spectrum based speech enhancement, Self-Attention (SA) method is applied to skip-connection to transform the feature of encoder to be compatible with the features of decoder. SA is a technique in which when generating an output sequence in a sequence-to-sequence tasks the weighted average of input is used to put attention on subsets of input, showing that noise can be effectively eliminated by being applied in speech enhancement. The three models using encoder and decoder features to apply SA to skip-connection are studied. As experimental results using TIMIT database, the proposed methods show improvements in all evaluation metrics compared to the Deep Complex U-Net (DCUNET) with skip-connection only.