• 제목/요약/키워드: connection failure

검색결과 609건 처리시간 0.026초

Running safety of high-speed train on deformed railway bridges with interlayer connection failure

  • Gou, Hongye;Liu, Chang;Xie, Rui;Bao, Yi;Zhao, Lixiang;Pu, Qianhui
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.261-274
    • /
    • 2021
  • In a railway bridge, the CRTS II slab ballastless track is subjected to interlayer connection failures, such as void under slab, mortar debonding, and fastener fracture. This study investigates the influences of interlayer connection failure on the safe operation of high-speed trains. First, a train-track-bridge coupled vibration model and a bridge-track deformation model are established to study the running safety of a train passing a deformed bridge with interlayer connection failure. For each type of the interlayer connection failure, the effects of the failure locations and ranges on the track irregularity are studied using the deformation model. Under additional bridge deformation, the effects of interlayer connection failure on the dynamic responses of the train are investigated by using the track irregularity as the excitation to the vibration model. Finally, parametric studies are conducted to determine the thresholds of additional bridge deformations considering interlayer connection failure. Results show that the interlayer connection failure significantly affects the running safety of high-speed train and must be considered in determining the safety thresholds of additional bridge deformation in the asset management of high-speed railway bridges.

Strength of connection fixed by TOBs considering out-of-plane tube wall deformation-Part 1: Tests and numerical studies

  • Wulan, Tuoya;Wang, Peijun;Xia, Chengxin;Liu, Xinyu;Liu, Mei;Liu, Fangzhou;Zhao, Ou;Zhang, Lulu
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.49-57
    • /
    • 2022
  • This paper presents a study on the behavior of a bolted T-stub to square tube connection using Thread-fixed One-side Bolts (TOBs) through tests and numerical simulations. It outlines a research work of four connections with focus on the failure modes and strengths of the connection under tensile load. It was observed that the thread anchor failure caused by shear failure of hole threads controlled the final failure of the connection in the tests. Meanwhile, the out-of-plane deformation of tube wall resulted in the contact separation between hole threads and bolt threads, which in turn reduced the shear strength of hole threads. Finite element models (FEMs) allowing for the configuration details of the TOBs fixed connection are then developed and compared with the test results. Subsequently, the failure mechanism of hole threads and stress distribution of each component are analyzed based on FEM results. It was concluded that the ultimate strength of connection was not only concerned with the shear strength of hole threads, but also was influenced by the plastic out-of-plane deformation of tube wall. These studies lay a foundation for the establishment of suitable design methods of this type of connection.

볼트이음방식의 블록전단파괴에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effects of Bolted Connection Type on the Block Shear Failure)

  • 이진옥;박경현;문지호;이학은;임남형
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5566-5571
    • /
    • 2012
  • 블록전단파괴는 인장부재의 한계상태에 해당하는 것으로 강구조물의 인장부재 또는 연결부 설계 시 주의를 요한다. 많은 연구 결과와 설계기준에서는 블록전단파괴에 대한 볼트 이음 방식의 영향을 고려하지 않고 있다. 본 연구에서는 볼트 이음 방식(지압이음과 마찰이음)이 블록전단파괴의 파괴모드와 파괴강도에 미치는 영향을 분석하고자 인장실험을 실시하였다. 실험결과의 분석으로부터 설계기준, 지압이음, 마찰이음에 따른 파괴모드의 차이를 제시하였으며 마찰이음에서 발생되는 마찰력으로 인한 블록전단파괴강도의 변화를 고찰하였다.

Central angle effect on connection behavior of steel box beam-to-circular column

  • Hwang, Won-Sup;Kim, Young-Pil;Yoon, Tae-Yang
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.531-547
    • /
    • 2009
  • This paper presents the experimental results on the strength behavior and failure modes of box beam-to-circular column connections in steel piers. Previous research introduced parameters such as joint central angles, extension of horizontal stiffeners, and use of equivalent web depth, which ignored strength behavior and failure modes of box beam-to-circular column connections. The use of equivalent web depth $d_2$ is not reasonable when central angle ${\alpha}$ is closer to $90^{\circ}$; therefore, a monotonic loading test has been performed for eight connection specimens. From the test, it is identified that the connection with the circular column is stronger than the connection with the box-sectioned substitution column. Also, the strength of the beam-to-column connections with horizontal stiffeners is higher than the one of the no column stiffeners. The concrete-filled effect of box beam-to-circular column connection is also investigated, and the experimental yield strength of the connection is compared with the theoretical one. Also, more a reasonable equivalent web depth is suggested. The failure modes of connection are clearly defined.

Cyclic shear test on a dowel beam-to-column connection of precast buildings

  • Magliulo, Gennaro;Ercolino, Marianna;Cimmino, Maddalena;Capozzi, Vittorio;Manfredi, Gaetano
    • Earthquakes and Structures
    • /
    • 제9권3호
    • /
    • pp.541-562
    • /
    • 2015
  • This paper aims at developing the knowledge on the seismic behavior of dowel beam-to-column connections, typically employed in precast buildings in Europe. Despite the large diffusion of the industrial buildings, a high seismic vulnerability was exhibited by these structures, mostly due to the connection systems deficiencies, during some recent earthquakes (Emilia 2012, Turkey 2011). An experimental campaign was conducted on a typical dowel connection between an external column and a roof beam. In this paper, the performed cyclic shear test is described. According to the experimental results, the seismic response of the system is evaluated in terms of strength, stiffness and failure mechanism. Moreover, the complete damage pattern of the test is described by means of the instrumentations records. The connection failure occurred due to the concrete cover failure in the column (splitting failure). Such a mechanism corresponds to a negligible energy dissipation capacity of the connection, compared to the overall seismic response of the structure. The experimental results are also compared with the results of a similar monotonic shear test, as well as with some literature relationships for predicting the strength of dowel connections under horizontal (seismic) loads.

노출형 철골기둥-베이스 플레이트 접합부의 내력평가를 위한 수치적 연구 (The Numerical Study on Capacity Evaluation of Exposed Steel Column-Base Plate Connection)

  • 이광호;유영찬;최기선;구혜진;유미나
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.26-34
    • /
    • 2016
  • 철골기둥-베이스 플레이트 접합부의 파괴유형은 베이스 플레이트 압축면과 인장면의 휨파괴, 앵커볼트의 인장파괴, 뽑힘, 전단파괴, 그리고 콘크리트 기초파괴 및 철골기둥의 소성힌지발생에 따른 파괴이다. 본 연구에서는 핀접합 또는 강접합으로 가정하여 설계되는 노출형 철골기둥-베이스 플레이트 접합부가 받을 수 있는 모멘트의 크기를 구하기 위하여, 한계상태 함수를 이용하여 철골기둥-베이스 플레이트 접합부의 휨성능 및 파괴유형을 예측하고 실험결과와 비교하였다. 한계상태함수를 이용하여 노출형 철골기둥-베이스 플레이트 접합부의 휨성능을 비교적 정확히 예측할 수 있는 범위는 축력이 있는 경우, 앵커볼트의 항복 또는 철골기둥의 항복으로 판별되었을 때이며 축력이 없는 경우, 베이스 플레이트의 항복으로 판별된 경우이다. 파괴유형까지 같이 고려할 경우, 축력이 있으며 앵커볼트의 항복으로 판별된 경우에만 한계 상태함수의 사용이 가능하다.

압축하중을 받는 1/12.5 축소모형 강관 연결부의 부착전단 거동에 대한 실험적 연구 (Experimental Study on Bond Behavior of 1/12.5 Scale Model of the Steel Tubular Joint Connection Subjected to Compressive Loads)

  • 오홍섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권3호
    • /
    • pp.19-26
    • /
    • 2024
  • 본 연구에서는 풍력타워 지지구조 연결부 1/12.5 축소모형 실험체의 압축거동을 실험적으로 분석하였다. 압축강도 140MPa의 고성능 시멘트계 그라우트를 연결부에 충전하였으며, 전단키 간격, 형상과 연결부 길이를 변수로 하여 실험을 수행하였다. 연결부 내의 전단키의 개수가 동일한 경우 연결부 길이보단 전단키의 간격이 작을수록 부착전단강도가 높게 나타났으며, 동일한 간격과 연결부 길이에서는 전단키의 높이가 높을수록 강도가 높게 나타났다. 또한 연결부 슬립량 1.0mm 내외까지 선형거동을 한 후 하중이 증가함에 따라 비선형 거동을 한후 7.0mm 내외의 슬립에서 최대 강도에 도달하는 것으로 나타났다. 전단키의 형상과 간격 등에 따라 강도가 증가함에 따라 파괴형태는 계면전단파괴에서 그라우트 파괴로 변화하는 것으로 나타났으며, 강섬유에 의해 취성적인 파괴는 발생하지 않는 것으로 나타났다.

Study and design of assembled CFDST column-beam connections considering column wall failure

  • Guo, Lei;Wang, Jingfeng;Yang, T.Y.;Wang, Wanqian;Zhan, Binggen
    • Steel and Composite Structures
    • /
    • 제39권2호
    • /
    • pp.201-213
    • /
    • 2021
  • Currently, there is a lack of research in the design approach to avoid column wall failure in the concrete filled double skin steel tubular (CFDST) column-beam connections. In this paper, a finite element model has been developed and verified by available experimental data to analyze the failure mechanism of CFDST column-beam connections. Various finite element models with different column hollow ratios (χ) were established. The simulation result revealed that with increasing χ the failure mode gradually changed from yielding of end plate, to local failure of the column wall. Detailed parametric analyses were performed to study the failure mechanism of column wall for the CFDST column-beam connection, in which the strength of sandwiched concrete and steel tube and thickness of steel tube were incorporated. An analytical model was proposed to predict the moment resistance of the assembled connection considering the failure of column wall. The simulation results indicate that the proposed analytical model can provided a conservative prediction of the moment resistance. Finally, an upper bound value of χ was recommend to avoid column wall failure for CFDST column-beam connections.

Plasticity-damage model parameters identification for structural connections

  • Imamovic, Ismar;Ibrahimbegovic, Adnan;Knopf-Lenoir, Catherine;Mesic, Esad
    • Coupled systems mechanics
    • /
    • 제4권4호
    • /
    • pp.337-364
    • /
    • 2015
  • In this paper we present methodology for parameters identification of constitutive model which is able to present behavior of a connection between two members in a structure. Such a constitutive model for frame connections can be cast in the most general form of the Timoshenko beam, which can present three failure modes. The first failure mode pertains to the bending in connection, which is defined as coupled plasticity-damage model with nonlinear softening. The second failure mode is seeking to capture the shearing of connection, which is defined as plasticity with linear hardening and nonlinear softening. The third failure mode pertains to the diffuse failure in the members; excluding it leads to linear elastic constitutive law. Theoretical formulation of this Timoshenko beam model and its finite element implementation are presented in the second section. The parameter identification procedure that will allow us to define eighteen unknown parameters is given in Section 3. The proposed methodology splits identification in three phases, with all details presented in Section 4 through three different examples. We also present the real experimental results. The conclusions are stated in the last section of the paper.

강-콘크리트 혼합거더 접합부의 정적 거동에 관한 연구 (A Study on the Static Behavior of Connection for the Steel-Concrete Hybrid Girder)

  • 김문겸;노병철;김정훈;박현철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.426-429
    • /
    • 2006
  • This paper focuses on the static behavior of prestressed and non-prestressed connections for the steel-concrete hybrid girder. Based on the experimental study, it is found that the girder with non-prestressed connection failed by local concrete failure at the connection area, and the studs are taken out from the concrete. In case of the girder with prestressed joint, the failure of the girder is initiated by the crack at the varying section area. The test results show that the girder with prestressed connection has higher load carrying capacity compare to the girder with non-prestressed connection by 12%. Therefore, the application of prestressing at the concrete-steel connection recommended for the more secure connection.

  • PDF