DOI QR코드

DOI QR Code

Study and design of assembled CFDST column-beam connections considering column wall failure

  • Guo, Lei (School of Civil Engineering, Hefei University of Technology) ;
  • Wang, Jingfeng (School of Civil Engineering, Hefei University of Technology) ;
  • Yang, T.Y. (Department of Civil Engineering, University of British Columbia) ;
  • Wang, Wanqian (School of Civil Engineering, Hefei University of Technology) ;
  • Zhan, Binggen (School of Civil Engineering, Hefei University of Technology)
  • Received : 2020.06.27
  • Accepted : 2021.04.04
  • Published : 2021.04.25

Abstract

Currently, there is a lack of research in the design approach to avoid column wall failure in the concrete filled double skin steel tubular (CFDST) column-beam connections. In this paper, a finite element model has been developed and verified by available experimental data to analyze the failure mechanism of CFDST column-beam connections. Various finite element models with different column hollow ratios (χ) were established. The simulation result revealed that with increasing χ the failure mode gradually changed from yielding of end plate, to local failure of the column wall. Detailed parametric analyses were performed to study the failure mechanism of column wall for the CFDST column-beam connection, in which the strength of sandwiched concrete and steel tube and thickness of steel tube were incorporated. An analytical model was proposed to predict the moment resistance of the assembled connection considering the failure of column wall. The simulation results indicate that the proposed analytical model can provided a conservative prediction of the moment resistance. Finally, an upper bound value of χ was recommend to avoid column wall failure for CFDST column-beam connections.

Keywords

References

  1. Ahmed, M., Liang., Q.Q., Patel., V.I. and Hadi., M.N.S. (2020), "Experimental and numerical investigations of eccentrically loaded rectangular concrete-filled double steel tubular columns", J. Constr. Steel Res., 167, 105949. https://doi.org/10.1016/j.jcsr.2020.105949.
  2. ATC-24 (1992), Guidelines for cyclic seismic testing of components of steel structures, Applied Technology Council; Redwood City, America.
  3. EC 3 (2005), Design of steel structures-Part 1-8: Design of joints, European Committee for Standardisation (CEN); Brussels, Belgium.
  4. GB50007 (2011), Code for design of building foundation, Ministry of Housing and Urban-Rural Development; Beijing: China
  5. GB50011 (2010), Code for seismic design of buildings, Ministry of Housing and Urban-Rural Development; Beijing: China
  6. Ghobarah, S. and Mourad, R.M. (1996), "Moment-Rotation Relationship of Blind Bolted Connections for HSS Columns", J. Constr. Steel Res., 40, 63-91. https://doi.org/10.1016/S0143-974X(96)00044-2.
  7. Guo, L., Wang, J.F., Wu, S.C. and Zhong, L.P. (2019), "Experimental investigation and analytical modelling of blind bolted flush or extended end plate connections to circular CFDST columns", Eng. Struct., 192, 233-253. https://doi.org/10.1016/j.engstruct.2019.04.053.
  8. Han, L.H., Ren, Q.X. and Li, W. (2011), "Tests on stub stainless steel-concrete-carbon steel double-skin tubular (DST) columns", J. Constr. Steel Res., 67(3), 437-452. https://doi.org/10.1016/j.jcsr.2010.09.010.
  9. Han, L.H., Yao, G.H and Tao, Z. (2007), "Performance of concrete-filled thin-walled steel tubes under pure torsion", Thin-Wall. Struct., 45, 24-36. https://doi.org/10.1016/j.tws.2007.01.008.
  10. Huang, H., Han, L.H., Tao, Z. and Zhao, X.L. (2009), "Analytical behavior of concrete-filled double skin steel tubular (CFDST) beam-columns under cyclic loading", Thin-Wall. Struct., 47, 668-680. https://doi.org/10.1016/j.tws.2008.11.008.
  11. Klippel, S. (1998), "Recent design developments with blind mechanically operated bolt systems for use with hollow section steel work", J. Constr. Steel Res., 46(1-3), 267-268 https://doi.org/10.1016/s0143-974x(98)00079-0.
  12. Liu, Y., Chuquitaype, M. and Elghazouli, A.Y. (2012), "Response and component characterisation of semi-rigid connections to tubular columns under axial loads", Eng. Struct., 41, 510-532. https://doi.org/10.1016/j.engstruct.2012.03.061.
  13. Oktavianus, Y., Chang, H.F., Goldsworthy, H.M. and Gad, E.F. (2017), "Component model for pull-out behaviour of headed anchored blind bolt within concrete filled circular hollow section", Eng. Struct., 148, 210-224. https://doi.org/10.1016/j.engstruct.2017.06.056.
  14. Schaumann, I. and Keindorf D. (2008), "Sandwich-towers for wind energy converters", Dewi Magazin., 460, 65-76.
  15. Wan, C.Y. and Zha, X.X. (2016), "Nonlinear analysis and design of concrete-filled dual steel tubular columns under axial loading". Steel Compos. Struct., 20(3), 571-597. https://doi.org/10.12989/scs.2016.20.3.571.
  16. Wang, F., Young B. and Gardner L. (2017), "Experimental investigation of concrete-filled double skin tubular stub columns with ferritic stainless steel outer tubes", Ce/papers., 1, 2070-2079. https://doi.org/10.1002/cepa.252.
  17. Wang, F.Y., Young, B. and Gardner, L. (2020), "CFDST sections with square stainless steel outer tubes under axial compression: Experimental investigation, numerical modelling and design". Eng. Struct., 207, 110189. https://doi.org/10.1016/j.engstruct.2020.110189.
  18. Ding, F.X., Wang., W.J., Lu., D.R. and Liu, X.M. (2020), "Study on the behavior of concrete-filled square double-skin steel tubular stub columns under axial loading", Struct., 23, 655-676. https://doi.org/10.1016/j.istruc.2019.12.008.
  19. Wang, J.F. and Guo, L. (2020), "Experimental and analytical behavior of square CFDST column blind bolted to steel beam connections", Int. Constr. Steel Struct., https://doi.org/10.1007/s13296-020-00310-y.
  20. Wang, J.F. and Guo, S.P. (2012), "Structural performance of blind bolted end plate joints to concrete-filled thin-walled steel tubular columns", Thin-Wall. Struct., 60, 54-68. https://doi.org/10.1016/j.tws.2012.07.006.
  21. Wang, J.F., Guo, L., Guo, X. and Ding, Z.D. (2019), "Seismic response investigation on CFDST column to steel beam blind-bolted connections", J. Constr. Steel Res., 161, 137-153. https://doi.org/10.1016/j.jcsr.2019.04.030.
  22. Wang, J.F., Wang, J.X. and Wang, H.T. (2017), "Seismic behavior of blind bolted CFST frames with semi-rigid connections", Struct., 9, 91-104. https://doi.org/10.1016/j.istruc.2016.10.001.
  23. Wang, J.F., Zhang, H.J. and Jiang, Z. (2016), "Seismic behavior of blind bolted end plate composite joints to CFTST columns", Thin-Wall. Struct., 108, 256-269. https://doi.org/10.1016/j.tws.2016.08.013.
  24. Wei, S., Mau, S.T., Vipulanandan, C. and Mantrala, S.K. (1995), "Performance of new sandwich tube under axial loading: experiment", J. Struct. Eng., 121(12), 1806-1814. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:12(1806).
  25. Yang, Y.F. and Han, L.H. (2009), "Experiments on rectangular concrete-filled steel tubes loaded axially on a partially stressed cross-sectional area", J. Constr. Steel Res., 65, 1617-1630. https://doi.org/10.1016/j.jcsr.2009.04.004.
  26. Yang, Y.F., Hou, C., Meng, C.Y. and Han, L.H. (2015), "Investigation on square concrete filled double-skin steel tube (CFDST) subjected to local bearing force: Experiments", Thin-Walled Struct., 94, 394-409. https://doi.org/10.1016/j.tws.2015.04.026.
  27. Zhao, H., Wang., R., Hou., C.C. and Lam., D. (2019), "Performance of circular CFDST members with external stainless steel tube under transverse impact loading", Thin-Wall. Struct., 145, 106380. https://doi.org/10.1016/j.tws.2019.106380.
  28. Zhao, X.L., Grzebieta, R., Ukur, A. and Elchalakani, M. (2002), "Tests of concrete-filled double skin (SHS outer and CHS inner) composite stub columns", Advances in steel structures - Proceedings of the 3rd international conference on advances in steel structures, Hong Kong, China, October.