• 제목/요약/키워드: connection design

검색결과 2,565건 처리시간 0.036초

플랫 플레이트-기둥의 외부 접합부의 변수 연구 (Numerical study on parameters of flat plate-column edge connections)

  • 안귀용;최경규;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.173-178
    • /
    • 2002
  • Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column edge connection. In the present study, numerical studies were performed for edge connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, drift, effective width around the connection were investigated. Based on tile findings of the numerical studies, the disadvantages of current design methods were discussed.

  • PDF

플랫 플레이트-기둥 접합부의 내진성능에 대한 해석연구 (Numerical Study on Seismic Resistance of Flat Plate-Column Connections)

  • 박홍근;최경규;황영현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.891-896
    • /
    • 2002
  • Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column connection. In the present study, numerical studies were performed for interior connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, shear, torsional moment around the connection were investigated. Based on the findings of the numerical studies, the disadvantages of current design methods were discussed.

  • PDF

철골 모멘트 연결부의 구조특성에 따른 지진 거동 연구 (Seismic Behavior of Steel Moment Connections with Different Structural Characteristics)

  • 조창빈
    • 한국안전학회지
    • /
    • 제17권2호
    • /
    • pp.76-84
    • /
    • 2002
  • The seismic behaviors of steel moment connections with different structural characteristics are investigated. The rupture index, which represents the fracture potential, is adopted to study the effect of concrete slab and the relative strength between the coin the beam, and Panel zone on the ductility of connections. The results show that the presence of slab increases the beam strength, imposes constraint near the beam top flange, and consequently, induces concentrated deformation near the beam access hall, which reduces the ductility of the connection. The total deformation capacity of the connection depends not only on the beam but also on the column and panel zone. Therefore, the detrimental slab effects and the relative strength should be considered in the seismic design of the connection.

Studies into a high performance composite connection for high-rise buildings

  • Lou, G.B.;Wang, A.J.
    • Steel and Composite Structures
    • /
    • 제19권4호
    • /
    • pp.789-809
    • /
    • 2015
  • This paper presents experimental and numerical studies into the structural behavior of a high performance corbel type composite connection adopted in Raffles City of Hangzhou, China. Physical tests under both monotonic and quasi-static cyclic loads were conducted to investigate the load carrying capacities and deformation characteristics of this new type of composite connection. A variety of structural responses are examined in detail, including load-deformation characteristics, the development of sectional direct and shear strains, and the history of cumulative plastic deformation and energy. A three-dimensional finite element model built up with solid elements was also proposed for the verification against test results. The studies demonstrate the high rigidity, strength and rotation capacities of the corbel type composite connections, and give detailed structural understanding for engineering design and practice. Structural engineers are encouraged to adopt the proposed corbel type composite connections in mega high-rise buildings to achieve an economical and buildable and architectural friendly engineering solution.

무선 센서 네트워크 기반 CCTV 제어 시스템 연구 (A Development of CCTV Control System Based on Wireless Sensor Network)

  • 조수형;김대환
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.219-220
    • /
    • 2009
  • Many surveillance cameras used in security system are controlled with RS-485 communication protocol. In this situation, if RS-485 connection can be replaced with wireless connection using sensor network technology, an installation will become ease because of no wired connection and also a deployment of cameras will become free. This paper explains about the design of wireless sensor node and the necessary implementation for an operation, which can be replacing RS-485 connection for the development of CCTV control system based on wireless sensor network. The hardware platform of sensor node was designed based on MicaZ and the software was developed based on TinyOS. To control surveillance cameras deployed on wide area, the supporting of multi-hop also was implemented. With the result of experiment deploying on real environment, it was revealed that the controller could control cameras quickly with wireless.

  • PDF

경량전철 고무차륜용 PC슬레브 궤도 (Precast Concrete Guideway of Automated Guideway Transit with Rubber Tire.)

  • 조능호;정원기;이규정;윤태양;이안호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.295-302
    • /
    • 2000
  • Slab guideway, surface treatment, heat line installation, and joint connection for Automated Guideway Transit with rubber tire are researched. While the AGT with rubber tire is constructed in city, the precast slab guideway must be considered a reduction of the construction period and the noise under construction. which related with environment. To do that, a basic design and the structural analysis for the precast slab guideway with rubber tire are studied. The surface treatment and the heat line installation of that are also compared with currently used methods. Tining method is applied to the surface treatment adopted from the concrete pavement application currently in use. The connection method between the slab of bridge and precast guideway are suggested with a bolt type and a bond type. To minimize noise and vibration of the connection while the AGT is in driving, the slop connection method can be enhanced the serviceability.

  • PDF

DB Connection Pool 관리를 위한 성능 진단도구의 설계 및 구현 (Design and Implementation of Performance Diagnosis Tool for DB Connection Pool Management)

  • 이재환;정인환
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2003년도 춘계학술발표논문집 (하)
    • /
    • pp.1507-1510
    • /
    • 2003
  • 웹 어플리케이션 개발 시 데이터베이스 시스템의 사용이 증가함에 따라 데이터베이스 시스템에 접속하는 커넥션 리소스 관리에 대한 중요성이 부각되고 있다. 본 논문은 웹 어플리케이션 구축 시 사용하는 데이터베이스 접속 풀(Database connection Pool)의 성능을 평가하고 진단하는 도구를 제안한다. 본 도구는 성능 및 진단을 통하여 웹 어플리케이션에 가장 적합한 최적화된 DB 커넥션 풀을 최적화하는 방법을 제시한다. 아울러 제안된 도구를 사용한 효과적인 데이터베이스 접속 풀(Database Connection Pool)의 관리 결과에 대하여 기술한다.

  • PDF

태양광 접속반의 자동 화재 예방 및 진압 시스템 설계 (Design of Automatic Fire Prevention and Suppression System for Photovoltaic Connection Module)

  • 이강원;양오
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.33-38
    • /
    • 2022
  • A solar power generation system uses a solar module that collects solar radiation energy, a connecting board that collects DC power generated from the solar module, and a diode to prevent reverse current from flowing from an inverter to the solar module. The existing photovoltaic connection module consists of only fuses and diodes for reverse polarity and overcurrent blocking, and does not have fire diagnosis, prevention, and suppression functions in the event of a fire. To solve this problem, this paper presents a method to monitor the internal state of the photovoltaic connection module using several sensors and to prevent and extinguish a fire using solenoid valves and fire extinguishing agents when a fire is detected. Through the experiment, it was confirmed that the proposed method normally suppresses the fire in event of a fire.

Effect of a two bearing lines deck on the bridge substructure

  • Shaker, Fatemeh;Rahai, Alireza
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.117-129
    • /
    • 2022
  • This research evaluated the different types of deck to pier connections effects (one or two elastomeric bearing lines and rigid) on a concrete bridges. Three-dimensional bridge models behavior with different deck to pier connections and different distances of two bearing lines were studied under the service load. Also, the detailed connection system with two elastomeric bearing lines was modeled to evaluate the effect of changing distance between two-lines. Results indicated that the proper location of elastomeric bearings has a major impact on the transferring forces to the substructure. Double elastomeric bearing lines have a behavior between one line and rigid connections. Transferring bending moment to the substructure in two-lines is more than the corresponding value of the one line. Moreover, an increase in the distance of two-lines lead to a significant increase in the rotational stiffness of the connection, and an analytical solution was investigated for their relation. In fact, the semi-rigidity effect of this connection and its change due to the distance of bearings should be considered in the design process.

임플랜트 지대주에 따른 나사 풀림의 연구 (THE INFLUENCE OF IMPLANT FIXTURE-ABUTMENT CONNECTION DESIGN ON SCREW LOOSENING)

  • 문양숙;박상원;방몽숙;양홍서;박하옥
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.174-184
    • /
    • 2006
  • Purpose: Current trend in implant dentistry is changing from external connection to internal connection. To evaluate the splinting of external and internal connection implant on screw loosening, 2-units prosthesis was fabricated with BioPlant $System^(R)$ of external connection type and Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. Material and Method: Experimental group is classified into three groups. 1) $G_1-EE$: 2-units prosthesis was fabricated with two Bioplant $System^(R)$ of external connection type. 2) $G_1-EI$: 2-units prosthesis was fabricated with one BioPlant $System^(R)$ of external connection type and one Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. 3) $G_1-II$: 2-units prosthesis was fabricated with two Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. In fabricating 2-units prosthesis, two hexed abutments are recommended when two implants are installed parallel, otherwise one hexed abutment is used on major occlusal force area and one nonhexed abutment is used on the other area. Since it is rare to find two implants being parallel, it is hard to fabricate prosthesis with passive adaptation using two hexed abutments. It is much more difficult to acquire passive adaptation when using hex abutment compared to nonhex abutment. To evaluate the influence of hexed and nonhexed abutment on screw loosening, 2-units prosthesis was fabricated with hexed and nonhexed abutment. Experimental group is classified into three groups. 1) $G_2-HH$: 2-units prosthesis was fabricated with two hexed abutments. 2) $G_2-HN$: 2-units prosthesis was fabricated with one hexed abutment and one nonhexed abutment. 3) $G_2-NN$: 2-units prosthesis was fabricated with two nonhexed abutments. Result: The results of comparing the detorque value after loading on a each prosthesis periodically are as follows. 1. In splinting group of external and internal connection implant, $G_1-II$ group demonstrated the biggest detorque value, followed by $G_1-EI$ group and $G_1-EE$ group. 2. There is no notable significance between external connection implant of $G_1-EI$ group and $G_1-EE$ group and also no significance between internal connection implant of $G_1-EI$ group and $G_1-II$ group. 3. $G_2-HH$ group showed higher detorque value than $G_2-HN\;and\;G_2-NN$ group. From the results, we can concluded that using both external connection and internal connection implant together is clinically acceptable and in order to acquire a good passive adaptation in fabricating 2-units implant prosthesis we can use two nonhexed abutments.