• Title/Summary/Keyword: cone model

Search Result 373, Processing Time 0.023 seconds

Comparison of model analysis measurements among plaster model, laser scan digital model, and cone beam CT image (석고 모형, 레이저 스캔 디지털 모형, 콘 빔 CT 영상 간의 모형 분석 계측치 비교)

  • Lim, Mi-Young;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.6-17
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the possibility of using a digital model and cone beam computed tomograph(CBCT) image for model analysis. Methods: Model analyses of CBCT images, plaster models, and digital models of 20 orthodontic patients with a permanent dentition with no proximal metal restorations, were compared. Results: The average differences of tooth size measurements were 0.01 to 0.20 mm, and the average difference of arch length discrepancy measurements were 0.41 mm in the maxilla and 0.82 mm in the mandible. The difference in Bolton discrepancy measurements was 0.17 mm for the anterior region and 0.44 mm overall but with no statistically significant difference. When comparing CBCT images with plaster models, the average differences in tooth size measurements were -0.22 to 0.01 mm, and the average differences in arch length discrepancy measurements were 0.43 mm in the maxilla and 0.32 mm in the mandible. Difference in Bolton discrepancy measurements were 0.35 mm in the anterior region and 1.25 mm overall. CBCT images showed significantly smaller overall Bolton discrepancy measurements. Conclusions: Although there were statistically significant differences in some model analysis measurements, the ranges of measurement errors of the digital model and CBCT images were clinically acceptable. Therefore, a digital model and CBCT image can be used for model analysis.

A Study on Centrifuge Model Experiments of Soft Soil Ground Installed with PBD (PBD가 설치된 연약지반의 원심모형실험에 관한 연구)

  • Jeong, Gil-Soo;Park, Byung-Soo;Jeon, Sang-Hyun;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.101-108
    • /
    • 2006
  • This study is the results of experimental and numerical study on the consolidational behavior of multi-layered soft soil ground installed with plastic board drains (PBD). Centrifuge model tests with a marine clay sampled from field were performed to investigate the consolidational behavior of multi-layered ground where a dredged soil was placed on the soft clay ground and PBDs were installed. Test results were compared with those of numerical analyses, using the 2-D equivalent model previously proposed. From test results, it was found that the amount of consolidation settlement occurred in the original ground due to embankment surcharge loads was in the range of 38% of total settlement in the whole ground. From the results of cone penetration tests executed after finishing the centrifuge model tests, the cone resistance was found to increase with depth. The measured water contents inbetween PBDs were in the ranges of 38~50% and their values tended to increase with increasing the distance between PBDs.

  • PDF

Comparison of geometrical methods to identify CME 3-D structures

  • Lee, Harim;Moon, Yong-Jae;Na, Hyeonock;Jang, Soojeong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.73-73
    • /
    • 2014
  • Several geometrical models (e.g., cone and flux rope models) have been suggested to infer 3-D parameters of CMEs using multi-view observations (STEREO/SECCHI) and single-view observations (SOHO/LASCO). To prepare for when only single view observations are available, we have made a test whether the cone model parameters from single-view observations are consistent with those from multi-view ones. For this test, we select 35 CMEs which are identified as CMEs, whose angular widths are larger than 180 degrees, by one spacecraft and as limb CMEs by the other ones. For this we use SOHO/LASCO and STEREO/SECCHI data during the period from 2010 December to 2011 July when two spacecraft were separated by $90{\pm}10$ degrees. In this study, we compare 3-D parameters of these CMEs from three different methods: (1) a triangulation method using the STEREO/SECCHI and SOHO/LASCO data, (2) a Graduated Cylindrical Shell (GCS) flux rope model using the STEREO/SECCHI data, and (3) an ice cream cone model using the SOHO/LASCO data. The parameters used for comparison are radial velocities, angular widths and source location (angle ${\gamma}$ between the propagation direction and the plan of the sky). We find that the radial velocities and the ${\gamma}$-values from three methods are well correlated with one another (CC > 0.8). However, angular widths from the three methods are somewhat different. The correlation coefficients are relatively not good (CC > 0.4). We also find that the correlation coefficients between the locations from the three methods and the active region locations are larger than 0.9, implying that most of the CMEs are radially ejected.

  • PDF

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

A Color Correction Method for High-Dynamic-Range Images Based on Human Visual Perception (인간 시각 인지에 기반을 둔 높은 동적폭을 갖는 영상 보정 방법)

  • Choi, Ho-Hyoung;Song, Jae-Wook;Jung, Na-Ra;Kang, Hyun-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.9
    • /
    • pp.1027-1038
    • /
    • 2015
  • For last several decades, the color correction methods have been proposed for HDR(high dynamic range) images. However, color distortion problems take place after correcting the colors such as halos, dominant color as well known. Accordingly, this article presents a novel approach in which the method consists of tone-mapping method and cone response function. In the proposed method, the tone mapping method is used to improve the contrast in the given HDR image based on chromatic and achromatic based on the CIEXYZ tristimulus value, expressed in c/m2. The cone response function is used to deal with mismatch between corrected image and displayed image as well as to estimate various human visual effects based on the CMCAT2000 color appearance model. The experimental results show that the proposed method yields better performance of color correction over the conventional method in subjective and quantitative quality, and color reproduction.

Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis

  • Paterson, Andrew;Franco, Vittorio;Patel, Shanon;Foschi, Federico
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.183-192
    • /
    • 2020
  • Purpose: This study was performed to assess the accuracy of preoperative cone-beam computed tomography (CBCT), when justified for other reasons, in locating the apical foramen and establishing the working length. Materials and Methods: Six electronic databases were searched for studies on this subject. All studies, of any type, were included if they compared measurements of working length with preoperative CBCT to measurements using an electronic apex locator (EAL) or histological reference standard. Due to the high levels of heterogeneity, an inverse-variance random-effects model was chosen, and weighted mean differences were obtained with 95% confidence intervals and P values. Results: Nine studies were included. Compared to a histological reference standard, CBCT indicated that the apical foramen was on average 0.40 mm coronal of its histological position, with a mean absolute difference of 0.48 mm. Comparisons were also performed to an EAL reference standard, but the conclusions could not be considered robust due to high levels of heterogeneity in the results. Conclusion: A low level of evidence is produced suggesting that preoperative CBCT shows the apical foramen to be on average 0.40 mm coronal to its histological position, with a mean absolute difference of 0.48 mm.

The consideration about pressure on surface of cone shape in experiments of supersonic wind tunnel I (초음속풍동실험에서 원뿔형상의 표면에서 측정되는 압력에 대한 고찰 I)

  • Lee, Jae-Ho;Choi, Jong-Ho;Yoon, Hyun-Gull;Kim, Kyu-Hong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.391-394
    • /
    • 2011
  • In this paper, the shock angle and effect had been compared with numerical data within supersonic area at an forebody such as missiles or an aircraft. By using supersonic wind tunnel in Seoul National University, The shock position and magnitude were measured in the model of cone shape according to mach number. The experiment had been conducted at mach number 2.0, 3.0, and 3.8. As a result, the shock position and magnitude are different from flow velocity, AOA, and AOS in some cases blockage effect had occurred.

  • PDF

A new minimally invasive guided endodontic microsurgery by cone beam computed tomography and 3-dimensional printing technology

  • Kim, Jong-Eun;Shim, June-Sung;Shin, Yooseok
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.29.1-29.7
    • /
    • 2019
  • Endodontic microsurgery is defined as the treatment performed on the root apices of an infected tooth, which was unresolved with conventional root canal therapy. Recently, the advanced technology in 3-dimensional model reconstruction based on computed tomography such as cone beam computed tomography has opened a new avenue in application of personalized, accurate diagnosis and has been increasingly used in the field of dentistry. Nevertheless, direct intra-oral localization of root apex based on the 3-dimensional information is extremely difficult and significant amount of bone removal is inevitable when freehand surgical procedure was employed. Moreover, gingival flap and alveolar bone fenestration are usually required, which leads to prolonged time of surgery, thereby increasing the chance of trauma as well as the risk of infection. The purpose of this case report is to present endodontic microsurgery using the guide template that can accurately target the position of apex for the treatment of an anterior tooth with calcified canal which was untreatable with conventional root canal therapy and unable to track the position of the apex due to the absence of fistula.

End shape and rotation effect on steel pipe pile installation effort and bearing resistance

  • Saleem, Muhammad A.;Malik, Adnan A.;Kuwano, Jiro
    • Geomechanics and Engineering
    • /
    • v.23 no.6
    • /
    • pp.523-533
    • /
    • 2020
  • The current study focuses on the effect of the end shape of steel pipe piles on installation effort and bearing resistance using the pressing method of installation under dense ground conditions. The effect of pile rotation on the installation effort and bearing resistance is also investigated. The model steel piles with a flat end, cone end and cutting-edge end were used in this study. The test results indicated that cone end pile with the pressing method of installation required the least installation effort (load) and showed higher ultimate resistance than flat and cutting-edge end piles. However, pressing and rotation during cutting-edge end pile installation considerably reduces the installation effort (load and torque) if pile penetration in one rotation equal to the cutting-edge depth. Inclusion of rotation during pile installation reduces the ultimate bearing resistance. However, if penetration of the cutting-edge end pile equal to the cutting-edge depth in one rotation, the reduction in ultimate resistance can be minimized. In comparing the cone and cutting-edge end piles installed with pressing and rotation, the least installation effort is observed in the cutting-edge end pile installed with penetration rate equal to the cutting-edge depth per rotation.

A Study on the Nasal Index of Malocclusion Patients Using Cone-Beam Computed Tomography 3D Program

  • Sung-Suk Bae;Hee-Jeung Jee;Yun-Ja Hwang;Ha-Rin Jang;Su-Jeong Kang;Jeong-Hyun Lee
    • Journal of dental hygiene science
    • /
    • v.24 no.3
    • /
    • pp.146-151
    • /
    • 2024
  • Background: Research is continuously being conducted on the relationship between the airway and malocclusion. The nose, as the upper part of the respiratory pathway, plays a critical role. While various international studies employ the Nasal Index classification for nasal morphology, domestic research remains scarce. This research investigates the proportions of nasal morphology in malocclusion patients utilizing a 3D software. Methods: The study evaluated 100 malocclusion patients in their 20s (40 Class I, 34 Class II, 26 Class III). Cone-beam computed tomography was used with the Mimics (ver. 22; Materialise) 3D program to model the skull and soft tissues of the patients in three views: coronal, sagittal, and frontal. Results: The results showed that in Class I, there were 5 leptorrhine (long and narrow) cases, 30 mesorrhine (moderate shape) cases, and 5 platyrrhine (broad and short) cases. In Class II, there were 3 leptorrhine, 25 mesorrhine, and 6 platyrrhine cases. In Class III, there were 2 leptorrhine, 21 mesorrhine, and 3 platyrrhine cases. Conclusion: The findings of this study indicate that there is no significant correlation between the size of the nose and malocclusion in patients. Additionally, additional research related to this study is expected to be necessary.