Experimental Investigation on Induced Voltage of the Secondary Conductors in Linear Induction Motor with Cage-type Secondary Fed by PWM Inverter (PWM 인버터로 구동되는 농형 선형유도전동기의 2차측 도체 전압 특성)

  • Kim, Kyung-Min;Park, Seung-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.21-24
    • /
    • 2002
  • In this paper, induced voltages of the secondary conductors of a linear induction motor(LIM) with cage-type secondary are measured and analyzed when the LIM is fed by PWM inverter. The attenuation constant of the induced voltage of the secondary conductors near entry and exit zones of the the travelling magnetic field are determined from the experiment results.

  • PDF

A Study on the Design of Branch Conductor in the Magnetic Pulse Generator (자기 펄스 발생기의 연결 도체 설계에 관한 연구)

  • SUH, JUBA
    • Journal of Industrial Technology
    • /
    • v.9
    • /
    • pp.101-107
    • /
    • 1989
  • The magnetic forming system must be able to store very important electric energy, several tens kilojoules, and flow this energy through the forming coil within some hundreds microseconds. So several hundreds kiloamperes of current can flow through the branch conductor. For the good performance of this type of machine, internal impedance must be minimized. By the computation of distribution of current inside the conductors using integral equation method, we can obtain the inductance and resistance of some dispositions of branch conductors and by comparison obtain some principles for the design of branch conductors in the high power magnetic pulse generator.

  • PDF

Calculation of Ampacity for Bare Overhead Conductors (가공송전선로용 나전선의 허용전류 산정에 대한 검토)

  • Sohn, H.K.;Lee, H.K.;Lee, E.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.303-305
    • /
    • 2000
  • Many standards have published for calculating the ampacity of bare overhead conductors. Although these standards use the same basic heat balance concept, they use different approaches to calculate ampacity ratings. This paper looks at the different approaches used to calculate individual heat balance terms, at the overall impact of these terms on the ampacity rating. And this paper is proposed to the selection of proper standard and atmospheric conditions for calculating the ampacity of bare overhead conductors.

  • PDF

Behaviors of the Spacers on the Galloping of Power Transmission Lines

  • Kim, Hwan-Seong;Nguyen, Tuong-Long;Byun, Gi-Sig
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.128-133
    • /
    • 2003
  • In this paper, we have proposed a method by using virtual simulation to calculate the behaviors of spacers to avoid conductor galloping with the hanging composite polymer spacer between conductors on different phases. We have considered with three types of modeling considerations for the analysis of galloping in power transmission lines, such as iced-single conductors without spacer, iced-single conductors with spacers, and iced-two bundle conductors with spacers. In simulation, the finite element method is used to calculate the structural response with geometric nonlinear behavior. The iced conductor is modeled by two beam-element faces with which it is connected. The ANSYS program is applied too. First, the calculation results show that the two beam-element model is very suitable to make a virtual simulation. Second, the amplitude of conductor galloping is reduced after hanged spacers. Third, when number of spacer is increased, the maximum magnitude of natural frequency of iced conductor will reduce. Final, the behaviors of spacers are verified in viewpoint of standard cases.

  • PDF

Complementary Calculation of Current Carrying Capacity for Bare Overhead Conductors (가공선용 나전선의 허용전류 산정 보완)

  • Son, Hong-Gwan;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.225-231
    • /
    • 2002
  • Many standards have Published for calculating of current carrying capacity for bare overhead conductors. Although these standards use the same basic heat balance concept, they use different approaches to calculate current carrying capacity, This paper looks at the four approaches used to calculate individual heat balance terms, at the overall impact of these terms on the current carrying capacity And this paper is proposed to the selection of proper standard and AC resistance within a country conditions for calculating the current carrying capacity of bare overhead conductors. So current carrying capacities are Proposed to some of conductors.

Development of ITER TF Cable-in-Conduit Conductors and Their Characteristics (ITER TF 초전도 도체 개발과 특성)

  • Kim, Hyoung-Chan;Oh, Dong-Keun;Park, Su-Hyeon;Kim, Kee-Man;Bruzzone, P.
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.108-115
    • /
    • 2009
  • As a participant taking part in the ITER TF conductor R&D program, we developed two toroidal field conductors with variations of conduit thickness resulting in the different void fraction of the conductors. The estimated void fractions of the conductors are 31% and 33%. In this paper we present the details of the TF conductor development and performance test results of them carried out by the measurement of current sharing temperature under cyclic loading. Regarding the conductor development, the internal-Sn-processed $Nb_3Sn$ strand characteristics, strand cabling, twist pitch and characteristics of the conduit materials are presented. For the understanding of the conductor design and performance, the conductor test results are presented and the effect of the conductor design parameters such as void fraction and twist pitch is discussed based on the results.

  • PDF

Analysis of Galloping Amplitude for Conductors With Inter-phase Spacers

  • Kim Hwan-Seong;Nguyen Tuong-Long
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.42-51
    • /
    • 2006
  • The main purpose of this paper is to calculate the behaviors of inter-phase spacers to reduce the amplitude of galloping in conductors. In simulation, three phases and iced-single/two-bundles conductors with/without spacers are considered in viewpoint of standard cases. The implicit/explicit finite element methods are used to calculate the transient response with geometric nonlinear behavior. The ANSYS/LS-DYNA program is also applied. Calculation results can be used to predict the positions to insert the inter-phase spacers between conductors.

Unbalace Current Analysis on the Bundled Conductors of the UHV Overhead Transmission Line (초고압 송전선로의 다도체 구성에 따른 불평형 전류 해석)

  • Jeong, Y.H.;Lee, H.K.;Sohn, H.K.;Cho, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1379-1381
    • /
    • 1999
  • The unbalance current on the bundled conductors of the UHV overhead transmission line is one of the factors affected on power transmission system. It is varied by distance between of bundled conductors and of phase to phase, phase arrangement. In this paper, we calculated unbalance current on the bundled conductors by a variety of line arrangements and also calculated magnetic field at the circumference of the line fed with this unbalance current.

  • PDF

A study of Dielectric Strength of Spacer for Tap Changer in a $SF^6 $ Gas Insulated Transformer ($SF^6 $ 가스변압기의 탭절환기용 스페이서의 절연내력에 관한 연구)

  • Heo, U-Haeng;Ha, Yeong-Sik;Hong, Jeong-Gyun;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.11
    • /
    • pp.556-562
    • /
    • 2001
  • Spacer is used between main tank and auxiliary tank for on load tap changer in gas insulated power transformer. This paper deals with electrical design of spacer and discusses different analysis method of between 2D FEM(finite element method) and 3D FEM. To design spacer, we modeled structure of two kind of coaxial cylinders of spacer conductors and analysised electric field of spacer at impulse and induced test voltage condition. Spacer has 13 conductors and electric field was changed according to arrangement of conductors. We could find out arrangement of conductors at which electric stress is minimum. And this arrangement was satisfied with actual test conditions.

  • PDF

Assessment of Short-Time Characteristic ACSR-OC Conductor (ACSR-OC 전선의 단시간 특성 평가)

  • Lee, Joong-Kwan;Kim, Dong-Muyng;Yi, Sue-Muk
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1446-1448
    • /
    • 2002
  • The short-time permissible temperature of an overhead distribution line conductor is determined by the softening characteristics of ACSR-OC, ACSR AW/OC 160, typical conductors employed in the overhead distribution line. Transient heat transfer equation and Newton's cooling law were applied to analyze the heating and cooling effects of the insulating conductors, respectively, and the error of co-relation was calibrated after simulating the softening test to assess the short-time characteristic of the insulating conductor. In order to verify the softening characteristic, the conductors were tested with heat cycle. The test was totally carried out 200 cycles, and 1 cycle was to heat and cool at 1.1 times permissible current of the conductor, 1.15 times for 120 minutes, respectively. After heating, the tensile strength and surface of the conductor were observed. In case of ACSR-OC, as the result of 100 hour heating test, the tensile strength of the insulator was 0.8 times the initial value. This is equivalent to the value of the conductors which are used for 10 years at sites.