• 제목/요약/키워드: conductor

검색결과 2,175건 처리시간 0.028초

안정화 층을 갖는 YBCO Coated Conductor와 BSCCO 선재의 결합이 과전류 통전 특성에 미치는 영향 (Effect of Transport Current Properties on Connecting of YBCO Coated Conductor having Stabilizer Layer and BSCCO Tape)

  • 두호익;김민주;박충렬;두승규;김용진;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.950-953
    • /
    • 2008
  • YBCO coated conductor called the second-generation superconducting tapes have resistance increase significantly more than BSCCO tapes in terms of the speed or amount when quench occurs, they may have different ranges of application. Such characteristics are thought to get different properties by selection of stabilizing materials in manufacturing superconducting tapes. It is important in selecting superconducting tapes which will be applied to power devices in the future. In this study, one kind of BSCCO tapes and two kinds of YBCO CC with different stabilizing materials and one kind of YBCO CC with non stabilizing materials were used to compare and examine transport characteristics in flux-flow state and quench state with each tape joint of HTS tapes.

Lifetime estimation of a covered overhead line conductor

  • Leskinen, Tapio;Kantola, Kari
    • Wind and Structures
    • /
    • 제6권4호
    • /
    • pp.307-324
    • /
    • 2003
  • The paper presents results of studies concerning wind-induced aeolian vibration and fatigue of a 110 kV covered conductor overhead line. Self-damping measurement techniques are discussed: power method is found to be the most reliable technique. A method for compensating tension variations during the self-damping test is presented. Generally used empirical self-damping power models are enhanced and the different models are compared with each other. The Energy Balance Analysis (EBR) is used to calculate the aeolian vibration amplitudes, which thereafter are converted to bending stress for the calculation of conductor lifetime estimate. The results of EBA are compared with field measurements, Results indicate that adequate lifetime estimates are produced by EBA as well as field measurements. Generally the EBA gives more conservative lifetime expectancy. This is believed to result from the additional damping existing in true suspension structures not taken into account by EBA. Finally, the correctness of the line design is verified using Cigre's safe design tension approach.

내열 도체가 적용된 가공 배전선의 적용 영향에 관한 연구 (Analysis of Distribution Power System with Thermal Conductor Distribution Lines)

  • 김명현;이경태;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.243-244
    • /
    • 2015
  • Power system has been improved during for a long time by customers demand. Power suppliers has researched the power system component for more electricity transmission. One of the research is apply the thermal conductors in new cable. The operational temperature of thermal conductors is higher than normal aluminum that thermal conductor is composed of aluminum, Zr(zirconium) and etc. Increase of operational temperature is growth of the transmission capability. Power suppliers was concerned about the increase of operation temperature by thermal conductors. Therefore, the thermal conductor has the possibility that expanded application in power system. In this paper analysed effect of thermal conductor in power distribution system.

  • PDF

고정자 권선 점적율을 극대화 하는 새로운 코일구조와 환형동선 코일구조간의 AC Resistance(Rac) 비교 (AC Resistance(Rac) comparison between the new type of coil structure and the annular copper coil to maximize the conductor occupying ratio)

  • 이의천;김용훈;이강원;이수웅;권순오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.784-785
    • /
    • 2015
  • This paper proposes a new structure of coil to maximize the conductor occupting ratio(conductor cross sectional area than the cross sectional area inside the slot) of the magnetic core. Further, assuming a case in which the 3-D coil is applied to a real motor. Analyze the current density distribution of the coil conductor by electromagnetic analysis method. Finally the AC resistance was measured according to the frequency of the coils. This expereiment is to calculate a optimal operating frequency to obtain high efficiency operational frequency range of motor.

  • PDF

전력케이블용 반도전층의 유전/절연특성과 온도 의존성 (A Temperature dependancy and dielectric/insulation properties for power cables)

  • 이종찬;허인성;김광수;박대희;이재관;김동찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1463-1466
    • /
    • 2002
  • In this paper, the thermal analysis and dielectric/insulation properties were investigated with considering the temperature depenence Using the sheet of semi-conductor/XLPE came from 22 kV power cables, the dielectric/insulation properties and temperature dependence were measured under 1kHz. According to the results we can verify that only semi-conductor sheet changed linearly, and with the unstable results. the dielectric/insulation properties of the semi-conductor/XLPE sheet show the highest value in the range of 40 $^{\circ}C$ and 50 $^{\circ}C$ and are rely on XLPE rather than semi-conductor in terms of the temperature.

  • PDF

전류분포가 3본-도체의 교류손실 특성에 미치는 영향 (Influence of Current Distributions on AC Loss Characteristics in a 3-conductor)

  • 정재훈;류경우
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.206-209
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The ac loss characteristics in the conductor have experimentally investigated. The loss tests indicate that the ac loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

2층 고온초전도 전력케이블 코어의 전자장 해석 (Electro-magnetic Field Analysis of 2-Layer HTS Power Transmission Cable Core)

  • 조전욱;주진홍;김석환;배준한;김해종;김해준;성기철;홍정표
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.269-271
    • /
    • 2003
  • A typical HTS power transmission cable has multi-layer conductor structure to increase the current capacity. The tapes of the innermost layer are wound on a round former, and adjacent tapes of another layer are separated by a thin insulating film. In steady state, the total current flows in the conductor layer, and consequently there is magnetic field between the inner and outer layer. This paper describes a magnetic field amplitude around the conductor layer and the HTS tape by a transport current. Also, this paper will help for future cable conductor prototypes.

  • PDF

전류분포가 3본-도체의 교류손실 특성에 미치는 영향 (Influence of Current Distributions on AC Loss Characteristics in a 3-conductor)

  • 정재훈;류경우
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.7-10
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The ac loss characteristics in the conductor have experimentally investigated. The loss tests indicate that the ac loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

전자계산기에 의한 배전선료전선 단면적의 경제적 설계법 (A Computer method in Economical Design of Conductor Sizes of Distribution Lines)

  • 박영문
    • 전기의세계
    • /
    • 제24권5호
    • /
    • pp.107-110
    • /
    • 1975
  • This paper describes computational algorithms and a computer program for optimum determinations of wire conductor sizes of radial or tree-type distibution lones with given constraints. Here, The objective function is defined as the total summation of the volume or weight of respective conductor materials required for buildingup the entire distributing system. Four categories of constraints are applied to the obiective function. That is, on the respective load points constraint is imposed by a specified voltage drop limit, and the respective line elements are capable of carrying the current safely(safety current) and also must maintain the minimum thickness in viewpoint of mechanical strength and legal requirements. And finally, the conductor sizes have to be selected among the standardized size levels of the products. These kinds of optimization problems cannot be solved by the ordinary optimization tediniques such as the Linear Programming Method, SUMT Technique, etc. This paper, therefore, successfully devised the powerful alorithms to solve the problem, using the particular properties or characteristics ingerent to the radial or tree-type distribution system. The computer program developed from the algorithms was applied to several sample systems and shown to be exact and very efficient.

  • PDF

A Square Coaxial Transmission Line with a Thin-Wire Inner Conductor to Measure the Absorbing Performance of Electromagnetic Absorbers

  • Kang, Tae-Weon;John Paul;John Paul
    • Journal of electromagnetic engineering and science
    • /
    • 제4권1호
    • /
    • pp.43-49
    • /
    • 2004
  • A low-frequency coaxial reflectometer(LCR) with a thin-wire inner conductor is designed and constructed to measure nondestructively the absorbing performance of electromagnetic absorbers in the frequency range of 10 MHz to 200 MHz. The LCR consists of a square coaxial transmission line and a network analyzer with a time-domain measurement capability. Inherent characteristics of a square coaxial line with a thin-wire inner conductor which deteriorate the impedance matching of the input port of the LCR are addressed. And the characteristics are improved by employing a multiwire inner conductor. Measured and calculated reflection losses of a flat ferrite tile absorber are presented.