• Title/Summary/Keyword: conductive safety

Search Result 93, Processing Time 0.021 seconds

Characteristics on Arc Waveform and RMS of Current by Conductive Powder (도전성 분말에 의한 아크전류의 파형 및 실효값 특성)

  • Kim, Doo Hyun;Kang, Yang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.63-68
    • /
    • 2013
  • This paper is aimed to make an analysis on characteristics of the parallel arc waveform and RMS of current at the electrical tracking state by conductive powder. In order to achieve the goal in this paper, field state investigation at metal processing companies in Chung-Nam province area was conducted. With the field state investigation, conductive powder were collected from metal processing companies. By experiment on electrical connector(breaker, connector) over which the conductive powder were scattered, arc waveform and RMS of current were measured. The measured waveform and RMS(root-mean-square) of current were analyzed to describe characteristics and patterns of electrical arc by the conductive powder. It was proved that conductive powder on electrical connector can flow electrical current enough to make electrical fire with high thermal energy. Also the change of sine waveform and RMS of current can be used to find out relationship between electrical fire and fault signal by conductive powder. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the metal processing companies.

Conductive Rubber for Enhanced Safety in Hydrogen-based Facilities from Electrostatic Discharge (도전성 고무 매트를 이용한 수소 기반 시설에서 제전 신뢰성 향상)

  • S. Lee;J. Ko;J. Song;C. Kim;C. Kim;H. S. Kim;M. E. Hur;Chung J. H.;H. J. Song
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.9-15
    • /
    • 2024
  • Hydrogen-based electricity and transportation systems are widely recognized as sustainable power sources. However, the low ignition energy of hydrogen, only 1/10th that of conventional fossil fuels, poses a safety concern involving the risk of ignition due to electrostatic discharge from facility workers. Therefore, anti-static systems are imperative for hydrogen-based electricity facilities. To address this, we propose a reliable conductive rubber mat (CRM) to ensure the safety of these facilities. Unlike conventional anti-static floors that utilize conductive paint (CP), the CRM features a uniform distribution of conductive components in chemically and mechanically stable rubber. As a result, the CRM is unyielding to polar solvents (such as ethanol and hydrosulfuric acid) and non-polar solvents (like mineral oil) without increasing its resistance. Moreover, the CRM can withstand mechanical stress. Consequently, the human-body voltage of workers on the CRM would be sufficiently low enough to protect them from hydrogen explosions, thereby enhancing overall safety.

Risk of Electric Arcs by Conductive Dust Accumulated on Circuit Breaker (차단기에 누적된 도전성 분진에 의한 아크 위험성)

  • Kim, Doo Hyun;Kang, Yang Hyun;Kim, Eun Jin;Hwang, Dong Gyu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.20-25
    • /
    • 2015
  • In general, the causes of the electrical fire are overcurrent, short circuit, poor contact, etc. This study is aimed to recognize the risk of electric arc to prevent electrical fires due to the conductive dust accumulated on the circuit breaker. The experiment was carried out by the method that conductive metal dust collected from the field is being accumulated on the experimental electrodes with gap of 13 mm until the arc is generated. In case that arc was generated, the amount of conductive dust was measured and the thickness was calculated. This experiments was conducted by particle size. In order to distinguish particle size, mesh size(60~100, 100~150, 150~200, 200~250mesh) was classified using a sieve. As the results of experiment for each of the particle sizes, it was confirmed that there is differences in the generation of arc depending on the thickness of dust accumulated.

Characteristic Analysis of Induction Phenomena in the Nearby Mesh Structure Conductive Part of Large Capacity Wireless Power Transmission System (대용량 무선전력전송 환경 인근 메쉬구조 도전부 유도현상 특성 분석)

  • Chae, Dong-Ju;Yi, Geon-Ho;Lim, Hyun-Sung;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.207-214
    • /
    • 2019
  • A large-capacity wireless power system is a technology that transmits electric power of kW or more in a noncontact type. Electric cars, electric buses, and electric railways. In order to increase the power transmission efficiency, a resonance method using a frequency of kHz is applied and the efficiency is 80 ~ 90%. In this case, the loss is 10 ~ 20% other than efficiency, and corresponds to several hundreds of W to several kW in kW class wireless power transmission. 35 kW wireless feed system environment, and induced current in the nearby conductive part was measured. As a result of analysis, it was confirmed that induction phenomenon is higher as the loop configuration of the conductive part per area is dense. The increase of the induced current in the mesh loop is characterized by the density of the nearby conductive part having a permeability per unit area. The concentration of the magnetic field by the permeability is increased and the induction phenomenon causing the induction current is increased. It was confirmed that induction phenomenon increases by about 2.7 times when 9 times dense structure is formed.

EMI Shielding Efficiency of Recycled plastic/Hybrid Conductive filer Composites filled Electro Arc furnace Slag (제강Slag 충진 폐플라스틱/복합 전도성 filler복합재료의 전자파 차폐 효과)

  • Kang Young-Goo;Song Jong-Hyeok
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.80-85
    • /
    • 2004
  • Electromagnetic interference(EMI) shielding characteristics of composite filled with Cu flake and carbon brush powder as hybrid conductive filler and EAF slag have been studied. The coaxial transmission line method of ASTM D4935-99 was used to measure the EMI Shielding effectiveness of composites as formulation in frequency rage $100\~1,000MHz$ The SE also increases with the increase in flier loading. The hybrid filler filled composites show higher SE compared to that of only Cu flake. The correlation between SE and conductivity of the various composites is also discussed. The results indicate that the composites having higher filler loading$({\geq}40wt.\%)$ can be used for the purpose of safety materials to protect hazardous electromagnetic interference.

Preparation and Properties of Polymer Blends Type Humidity Sensor for Process Safety (공정안전용 Polymer Blend형 습도센서의 특성 연구)

  • Kang Young-Goo;Cho Myoung-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.51-56
    • /
    • 2004
  • Conductive polymer blends and composites are widely used for different safety application such as electrostatic charge dissipation(ESD), electromagnetic interference(EMI) shielding, electrostatic prevention and safety chemical sensor. In order to prepare a impedance-type humidity sensor that is durable at high humidities and high temperature, electically conductive polymer blends based on diallyldimethylammonium chloride(DADMAC) and epoxy were prepared in this study. The polymer blends type conductive ionomer exhibits reaction each other DADMAC and epoxy in FT-IR and DSC analysis. The blends material was traced by new peak at 1600cm-1 and appeard improvement of thermal resistance by melting point shift. Alumina substrate was deposited a pair of gold electrodes by screen printing. The blend material were spin-coated with a thin film type on the surface of alumina substrate. The polymer bleld type sensor exhibits a linear impedance increasing better than DADMAC coated humidity sensor. Also it shows good sensitivity, low hysteresis and durability against high humidity.

Effects of Thermal Conductivities on Temperature History of Massive Concrete Structures (국내 시방서와 ACI 규준 열전달율이 매스콘크리트 온도이력에 미치는 영향)

  • 장동일;손영현;조광현;김광일
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.122-126
    • /
    • 1999
  • In this study, using the temperature history analysis, the influences of the conductive values of wooden form, which are specified by Korean Standard for Concrete and ACI Practice Manual for Concrete, on the temperature history were examined. And, the calculated temperature history is compared with the measured temperature history. In the examination for the influences of the conductive values of wooden form, the value recommended by the Korean Standard can more closely predict the themperature history at the points which the variation of the boundary condition should be considered.

  • PDF

Study on the Electric Continuity Measurements of Green Car for Human Body Safety (친환경자동차의 인체 안전을 위한 전기적 연속성 측정 연구)

  • Kim, Hyang-Kon;Lee, Ki-Yeon;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.351-356
    • /
    • 2009
  • In this study, we analyzed and experimented about electric continuity for human body safety from green cars. And we compared power systems of HEV and examined about human body effect of current and time. We investigated internal and external standards and regulations for human body safety from high voltage electrical equipments. Indirect contact refers to contact between the human body and exposed conductive parts. According to UNECE R100, ISO 23273-3, ISO 6469-3 and Japanese Regulation Attachment 101, electric continuity between any two exposed conductive parts shall not exceed $0.1{\Omega}$. The value of electric continuity was measured below $0.1{\Omega}$ at the actual condition of green car. We expected that the results of these experiments can utilize to data for electrical safety of green car.

Comparative Anatomy of Diffuse-Porous Woods Grown in Korea (I) -Characteristics by Simple Correlation and Principal Component Analysis- (한국산(韓國産) 산공재(散孔材)의 해부학적(解剖學的) 특성(特性)에 관한 비교연구(比較硏究)(I) -단순상관(單純相關)과 주성분(主成分) 분석(分析)에 의한 특성(特性)-)

  • Chung, Youn-Jib;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.46-53
    • /
    • 1995
  • The anatomy of Korean diffuse-porous woods, 36 families, 75 genera, 145 species, 215 specimens was described and analyzed. Sixteen wood anatomical characters, habit and phenology factors were determined by simple correlation and principal component analysis. Strong positive correlations were found between vessel element length and fiber length, ray width and ray height, simple pits of fiber wall and paratracheal parenchyma distribution. The results of principal component analysis (PCA) disclose the primitive characteristics and the direction of xylem evolution of Korean diffuse-porous woods. The xylem evolution scenario for Korean dicotyledonous woods is considered to be developed in the direction of decreasing trends of vessel frequency, vessel element length, and length/diameter(L/D) ratio of vessel element but increasing trends of vessel diameter, fiber length/vessel element length(F/V) ratio, libriform wood fibers, simple perforation, and homogeneous ray composition. Increase of vessel diameter and decrease of vessel frequency seem to be related to the improvement of conductive efficiency, and increase of the vessel element length and occurrence of scalariform perforation in vessel element may be related to enhanced of conductive safety. Also the libriform wood fibers and ray features appear to have relationship with mechanical support and nutrient metabolism, respectively.

  • PDF

Damage Detection in Fiber Reinforced Composites Containing Electrically Conductive Phases

  • Shin, Soon-Gi;Hideaki Matsubara
    • The Korean Journal of Ceramics
    • /
    • v.6 no.3
    • /
    • pp.201-205
    • /
    • 2000
  • Fiber reinforced plastic (FRP) composites and ceramic matrix composites (CMC) which contain electrically conductive phases have been designed and fabricated to introduce the detection capability of damage/fracture detection into these materials. The composites were made electrically conductive by adding carbon and TiN particles into FRP and CMC, respectively. The resistance of the conductive FRP containing carbon particles showed almost linear response to strain and high sensitivity over a wide range of strains. After each load-unload cycle the FRP retained a residual resistance, which increased with applied maximum stress or strain. The FRP with carbon particles embedded in cement (mortar) specimens enabled micro-crack formation and propagation in the mortar to be detected in situ. The CMC materials exhibited not only sensitive response to the applied strain but also an increase in resistance with increasing number of load-unload cycles during cyclic load testing. These results show that it is possible to use these composites to detect and/or fracture in structural materials, which are required to monitor the healthiness or safety in industrial applications and public constructions.

  • PDF