• 제목/요약/키워드: conditioning factor

검색결과 492건 처리시간 0.03초

미세유로의 단상 유동 및 열전달에 대한 실험적 연구 (Experimental Studies on Single Phase Flow and Heat Transfer in Microchannels)

  • 김병주;김건일
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.795-801
    • /
    • 2008
  • An experimental study has been performed on the single phase flow and convective heat transfer in trapezoidal microchannels. The microchannel was about $270{\mu}m$ wide, $800{\mu}m$ deep. and 7 mm long, which might ensure hydrodynamically fully-developed laminar flow at a low Reynolds number. The experiments were conducted with R1l3 and water, with the Reynolds number ranging from approximately 30 to 5000 for friction factor and 30 to 700 for the Nusselt number. Friction factors in laminar are found to be in good agreement with the predictions of existing correlation suggesting that a conventional analysis approach can be employed in predicting flow friction behavior in microchannels. However turbulent friction factors are hardly predictable by the existing correlations. The experimental results show that the Nusselt number is not a constant but increases almost linearly with the Reynolds number even the flow is fully developed (Re < 100). The dependence of the Nusslet number on the Reynolds number is contradictory to the conventional theory. At a Reynolds number greater than 100, the Nusselt number increases slowly with the Reynolds number, where thennally developing flow is responsible for the increase of the Nusselt number with the Reynolds number.

연간 성능을 고려한 가정용 태양열-흡수식 히트펌프의 에너지 절약효과 분석 (An Analysis of Energy Savings on the Solar-Absorption Heat Pump Systems for the Residential Use with the consideration of Annual Performance)

  • 이재효;이관수;원승호;이명호
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.263-275
    • /
    • 1991
  • Studies on the annual performance of three different type of solar-absorption heat pump system (parallel type, series type, and generator type) are carried out by using the computer simulation. These include the calculation of solar energy from the solar collector, and the revision of computer package, developed by Oak Ridge National Laboratory, to predict the annual performance. Finally using weather data and load conditions, the annual performance are obtained. Results show that the annual operating costs of three solar-absorption heat pump systems are almost same values and 44% lower than that of the pure absorption heat pump system. The total annual input energys of solar-absorption heat pump systems are also about 44% lower than that of the pure absorption heat pump. The nominal size of the solar-absorption heat pump systems can be reduced to a value of 55% that of the pure absorption heat pump that would normally be specified under identical conditions.

  • PDF

직관채널의 마이크로 판형열교환기 열적 성능 특성 (The Characteristics of Thermal Hydraulic Performance for Micro Plate Heat Exchanger with Straight channel)

  • 김윤호;이규정;서장원;전승원
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.767-774
    • /
    • 2008
  • This paper presented the heat transfer and pressure drop characteristics for micro plate heat exchanger with straight channel. The metal sheets for straight channel are manufactured by chemical etching and fabricated micro plate heat exchangers by using the vacuum brazing of bonding technology. The performance experiments are performed within the Reynolds numbers range of 15$\sim$250 under the same flow rate conditions for hot and cold sides. The inlet temperature of hot and cold water are conducted in the range of $30^{\circ}C{\sim}50^{\circ}C$ and $15^{\circ}C{\sim}25^{\circ}C$, respectively. Heat transfer rate and pressure drop are evaluated by the Reynolds numbers and mass flow rates as the inlet temperature variations of the hot and cold sides. Correlations of Nusselt number and friction factor are suggested for micro plate heat exchanger with straight channel using the results of performance experiment.

욕조의 보온성능연구 (A Performance Equation of Bath Tubs)

  • 이병호;서정일
    • 대한설비공학회지:설비저널
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 1981
  • In this paper, a new performance equation of bath tubs has been derived, which is very characteristically illuminating and in good agreement with experiments : $$T=T_{\infty}+(T_0-T_{\infty})e-\frac{k(A'_f+A_0)}{Mc_{P{\Delta}x}t$$, where $T_{\infty}$ is the temperature of the bathroom, $T_0$ that of the bathwater at t=0, k the overall heat conductivity of the tub- wall, $A'_f$ the equivalent surface area to the wall, $A_0$ the submerged area of the tub-wall, M mass of the bath-water, $C_p$ the specific heat of the bathwater and ${\Delta}x$ the thickness of the tub-wall. Here the equivalent-free surface area is written as $$A'_f=mA_f,\;m=const.(1-{\phi})^{0.88}$$ : where m is a numerical factor which is determined by a simple experiment and some calculation, {\phi}$ the relative humidity and $A_f$ the real free-surface area. From this study, it has been clarified that cooling of bath-water is mainly due to mass-transfer through evaporation from the free surface and conductive heat loss through the tub-wall is minor, which rather gaily mock at common sense. The effect of keeping bathwater warn by increase of the tub-wall thickness is also analyzed by a new idea of the thickness gain factor.

  • PDF

민첩성과 균형감각 간의 상호관계 (Correlation between agility and balance)

  • 최보람
    • 대한물리치료과학회지
    • /
    • 제30권1호
    • /
    • pp.23-30
    • /
    • 2023
  • Background: While agility is a critical factor in the performance of sport in the court field, due to the diversity of agility occurrences, it is generally difficult to develop by strength and conditioning training. Previous study reported the correlation with the static balance and agility. However, the correlation between dynamic balance and agility is insufficient. It is necessary to study how static and dynamic balance affect agility respectively, for agility development. Design: Cross sectional correlational study design Methods: Twenty young women participated in the study. Three tests were used : one leg stance(static balance),Y-balance(dynamic balance), side-step(agility). One leg stance measured time, Y-balance measured distance, and side-step measured number of times. Correlation between balance and agility was used by Pearson Correlation. Results: One leg stance and side steps were shown to be not correlated. The Y balance and the side step showed with a moderate positive correlation. Conclusion: Agility is a decisive factor in fast-moving sports performance, which is generally difficult to improve with muscle strength and conditioning training. Since the correlation between dynamic balance and agility was found in this study, the importance of dynamic balance was found to improve agility to promote coordination.

가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구 (An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System)

  • 공형진;강성재;윤경식;임효재
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

핀-튜브 열교환 구조를 갖는 복합집열기에서 핀 높이 및 간격에 따른 공기열 이용 액체 가열 성능에 관한 수치해석 연구 (Numerical Analysis on Heat Gain of Liquid from Ambient Air with Various Fin Heights and Pitches of Fin-and-Tube Heat Exchanger in Hybrid Solar Collector)

  • 최휘웅;파쿠르 로커만;류남진;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제36권3호
    • /
    • pp.53-61
    • /
    • 2016
  • Solar assisted heat pump system uses solar thermal energy as a heat source of evaporator of heat pump. So, COP can be enhanced as well as collector efficiency. For improving performance of this system, some research about hybrid solar collector that has fin-and-tube heat exchanger has been conducted. This collector can get a thermal energy from ambient air for liquid heating, so heated liquid can be used as a heat source of evaporator in heat pump even the solar radiation is not enough. In this study, numerical analysis was conducted for confirming heat gain of liquid according to fin height and pitch of fin-and-tube heat exchanger in collector. As a result, higher heat gain was obtained on lower fin height and narrow fin pitch, but the pressure drop also increased with increment of heat gain. Thus the JF factor considering both heat transfer enhancement and pressure drop was investigated and the maximum value was shown when the fin height and pitch were 40mm and 45mm. So it is considered that this installation condition has a highest heat transfer improvement when comparing with pressure drop. However heat gain of liquid at this condition was less than the other installation conditions of fin pitch on same height. Then, after establishing a proper minimum heat gain of liquid, actual production and experiment of collector will be conducted with fin height and pitch showing maximum JF factor and satisfying selected minimum heat gain of liquid on the basis of results of this study.

공기식 태양광/열 시스템 공기채널 내 여러 저항체 설치에 따른 전열성능에 관한 CFD 해석 (CFD Analysis on the Heat Transfer Performance with Various Obstacles in Air Channel of Air-Type PV/Thermal Module)

  • 최휘웅;파쿠르 로커만;김영복;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.33-43
    • /
    • 2018
  • PV/Thermal module is the combined system, which consist of a photovoltaic module and solar thermal collector that can obtain electrical power and thermal energy simultaneously. Thus the power generation can be increase by decreasing the temperature of photovoltaic module and thermal energy retrieved from module also can be used for heating system. In this study, Heat transfer performance of air type PV/Thermal module was confirmed with various bottom obstacles that can be installed easily to real photovoltaic module by CFD (computational fluid dynamics) analysis. Eight type obstacles were investigated according to the shape and arrangement. As a result, nusselt number represent heat transfer performance was increased about 86% compare with the basic type PV/Tthermal module that has no obstacle and triangle type obstacle had higher value than other types. But pressure drop was also increased with increment of heat transfer enhancement. Thus the performance factor considering both heat transfer and pressure drop was confirmed and V-fin type obstacle arranged in a row for Reynolds number below 9,600 and protrusion type obstacle arranged in zigzag for Reynolds number above 14,400 were shown higher performance factor than other types. From these results, V-fin type obstacle arranged in row and protrusion type obstacle arranged in zigzag were considered as a proper type for applying to real PV/thermal module according to operating condition. But the heat transfer performance can be changed by the geometric conditions of obstacle such as height, width, length and arrangement. Thus, it could also confirmed that the optimal condition and arrangement of this obstacle need to be found in further study.

AC-AC Voltage Regulator Conditioning Converter with Three Control Schemes

  • Ahmed, Nabil A.;Miyatake, Masafumi;Kang, Ju-Sung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.169-173
    • /
    • 2005
  • In this paper, a comparative study of modified phase-angle, extinction-angle, and pulse width modulation control techniques for the purpose of power factor improvement of single-phase AC-AC voltage regulators have been illustrated as applied to a single-phase ac voltage converter by an example of the widely used single-phase induction motor as a dynamic load. Observations on power factor, displacement factor and total harmonic distortion factor are described and discussed on the basis of the simulated and measured results of this work.

  • PDF

초고층 건물의 제연영향요소에 따른 수직피난공간 압력분포 시뮬레이션 (A Study on the Pressure Difference of Smoke Control Influence Factor in the Super High-rise Building)

  • 최승혁;이동윤;전현도;박진철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.130-135
    • /
    • 2009
  • These days, the super high-rise buildings construction plans are increased in Korea. But the stack effect in the super high-rise building interrupts the smoke control system's operation because of pressure difference, so it is more dangerous than the general building when firing. Therefore it needs to study about the pressure difference in the super high-rise buildings. We research the smoke control influence factor in the super high-rise building. Reflecting the influence factor, the simulation is practiced the case by case.

  • PDF