• Title/Summary/Keyword: condition factor (k)

Search Result 2,647, Processing Time 0.031 seconds

Experimental Study on Regenerator Under Cryogenic Temperature and Pulsating Pressure Conditions (극저온 맥동 압력 조건에서의 재생기에 관한 실험적 연구)

  • Nam, Gwan-U;Jeong, Sang-Gwon;Jeong, Eun-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1095-1101
    • /
    • 2002
  • An experimental apparatus was prepared to investigate thermal and hydrodynamic characteristics of regenerator at cryogenic temperature under pulsating pressure condition. The regenerator was pressurized and depressurized by a compressor with various operating frequencies. Cold end of the regenerator was maintained around 100 K by means of a liquid nitrogen heat exchanger. Instantaneous gas temperature and mass flow rate were measured at both ends of the regenerator during the whole pressure cycle. Pulsating pressure drop across the regenerator was also measured to see if it could be predicted by a friction factor at steady flow condition. The operating frequency of pressure cycle was varied between 3 and 60 Hz, which are typical operating frequencies of Gifford-McMahon, pulse tube, and Stilting cryocoolers. First, the measured friction factor for typical wire screen mesh regenerator was nearly same as steady flow friction factor for maximum oscillating Reynolds number up to 100 at less than 9 Hz. For 60 Hz operations, however, the discrepancy between oscillating flow friction factor and steady flow one was noticeable if Reynolds number was higher than 50. Second, the ineffectiveness of regenerator was directly calculated from experimental data when the cold-end was maintained around 100 K and the warm-end around 293 K, which simulates an actual operating condition of cryogenic regenerator. Influence of the operating frequency on ineffectiveness was discussed at low frequency range.

Integrated Boost-Flyback ZCS Quasi-Resonant Power Factor Preregulator (부스트-플라이백 결합형 ZCS Quasi-Resonant 역률개선 컨버터)

  • 이준영;문건우;김현수;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.91-98
    • /
    • 1999
  • An integrated ZCS quasi-resonant converter(QRC) for the power factor correction with a single switch is presented in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of the input current. The proposed converter gives the good power factor, low line current harmonics, and tight output regulation. The input current waveform of the prototype designed using design equations shows about 15% of total harmonic distortion at rated condition. Also, the efficiency and power factor can be obtained about 86% and 0.985, respectively, at rated condition. The proposed converter is suitable for a low power level converter with a tightly regulated low output voltage and switching frequency of more than several hundreds kHz.

  • PDF

Development of an Index for the Evaluation of Intake Booming Noise of a Passenger Car (차량의 흡기부밍소음 평가지수 개발)

  • Park Y. W.;Chai J. B.;Jang H. K.;Lee J. K.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.884-890
    • /
    • 2004
  • In this paper, an index for the evaluation of vehicle intake booming noise is developed through a correlation analysis of objective measurement data and subjective evaluation data. First, intake orifice noise is measured at the wide-open test condition. And then, acoustic transfer function between intake orifice noise and interior noise at the steady state condition is estimated. Simultaneously, subjective evaluation was carried out with a ten-scale score by 8 engineers. Next, the correlation analysis between the psycho-acoustic parameters derived from the measured data and the subjective evaluation is performed. The most critical factor was determined and the corresponding index for the intake booming noise is obtained from the multiple factor regression method. At last, the effectiveness of the proposed index is validated.

Characteristics of Fault Current Division Factor & Groud Potential Rise of a Substation fed exclusively by Power Cables (지중케이블 변전소의 고장전류 분류율과 접지전위상승 특성)

  • Choi, Jong-Kee;Jung, Gil-Jo;Kim, Seon-Gu
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.295-297
    • /
    • 1998
  • This paper shows characteristics of fault current division factor $S_f$, which is a ratio of earth- return current to total fault current, at a substation fed exclusively by power cables under unsymmetrical fault condition, such as single line-to-ground fault. In substation grounding system design, $S_f$ is a very important factor determining GPR, touch and step voltage at a substation under fault condition. In case of substations fed by overhead lines, 40-60% of $S_f$ has been typically used, although it is a very conservative value with no other network conditions considered. It is authors' hope that $S_f$ presented in this paper could hopefully be a basic reference in designing of substation grounding system, especially for a substation fed exclusively by power cables.

  • PDF

Online condition assessment of high-speed trains based on Bayesian forecasting approach and time series analysis

  • Zhang, Lin-Hao;Wang, You-Wu;Ni, Yi-Qing;Lai, Siu-Kai
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.705-713
    • /
    • 2018
  • High-speed rail (HSR) has been in operation and development in many countries worldwide. The explosive growth of HSR has posed great challenges for operation safety and ride comfort. Among various technological demands on high-speed trains, vibration is an inevitable problem caused by rail/wheel imperfections, vehicle dynamics, and aerodynamic instability. Ride comfort is a key factor in evaluating the operational performance of high-speed trains. In this study, online monitoring data have been acquired from an in-service high-speed train for condition assessment. The measured dynamic response signals at the floor level of a train cabin are processed by the Sperling operator, in which the ride comfort index sequence is used to identify the train's operation condition. In addition, a novel technique that incorporates salient features of Bayesian inference and time series analysis is proposed for outlier detection and change detection. The Bayesian forecasting approach enables the prediction of conditional probabilities. By integrating the Bayesian forecasting approach with time series analysis, one-step forecasting probability density functions (PDFs) can be obtained before proceeding to the next observation. The change detection is conducted by comparing the current model and the alternative model (whose mean value is shifted by a prescribed offset) to determine which one can well fit the actual observation. When the comparison results indicate that the alternative model performs better, then a potential change is detected. If the current observation is a potential outlier or change, Bayes factor and cumulative Bayes factor are derived for further identification. A significant change, if identified, implies that there is a great alteration in the train operation performance due to defects. In this study, two illustrative cases are provided to demonstrate the performance of the proposed method for condition assessment of high-speed trains.

Effects of $K_{II}$ on fatigue crack propagation behavior of wedzone in generally rolled steel for marine structure (박용 구조물용 일반압연강 용접부의 피로균열 전파거동에 미치는 $K_{II}$의 영향)

  • 한문식;김상철
    • Journal of Welding and Joining
    • /
    • v.6 no.3
    • /
    • pp.43-55
    • /
    • 1988
  • An experimental study was carried out to identify the fatigue fractue behavior of weld zone in generally rolled steel for marine structure. The bending an shear loads were applied simultaneously on the specimens to simulate real load condition for marine structure. The effect of the stress intensity factor under mode I with II loading condition on the initiation and the propagation of a crack were investigated, with particular emphaiss on mode II. When the $K_{II}$ stress intensiy factor in mode II was applied under mode I load condition, the growth behavior of a crack seems to be affected mainly by the anisotropic characteristic of materials. Especially, when the crack was located in and near the weld zone and parallel to th weld line, the propagation behaviour was turned out to be quite different from that of the base metal along the direction transverse to the weld line. In general, the propagation veiocity of the cracks in and near the weld zone was found to be slower that the velocity in base metal.

  • PDF

Application of Rigid Lid Boundary Condition for Three Dimensional Flow Analysis beneath Floating Structure (부유체하부의 3차원 흐름해석을 위한 Rigid lid 경계조건의 적용)

  • Hong, Nam-Seeg
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.55-62
    • /
    • 2012
  • In this paper, the rigid lid boundary condition is applied to simulate the influence of floating structures such as ships or pontoons, and the pressure term in both the momentum equations and continuity equation are modified. The pressure of a floating structure under the free surface is dependent on the draft of the structure, generally called a ship. If the free surface is covered by a floating structure, the free surface cannot move freely. The water level should be fixed, using a rigid lid boundary condition. This boundary condition is implemented by reducing the storage area of the grid cell with a factor between zero and one. The numerical model developed by Hong (2009) is verified through a comparison with experimental results, and the influence of the reduction factor is investigated using the verified numerical model.

Strength analysis of mechanical transmission using equivalent torque of plow tillage of an 82 kW-class tractor

  • Kim, Taek-Jin;Kim, Wan-Soo;Kim, Yeon-Soo;Chung, Sun-Ok;Park, Seong-Un;Hong, Soon-Jung;Choi, Chang-Hyun;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.4
    • /
    • pp.723-735
    • /
    • 2019
  • The power-train is the most important component of an agricultural tractor. In this study, the strength of the driving gear transmission of an 82 kW-class tractor was analyzed using equivalent torque during plow tillage. The load measurement system consisted of an engine revolution speed sensor, torque-meters, revolution speed sensors for four axles, and pressure sensors for two hydraulic pumps. The load data were measured during plow tillage for four speed stages: F2 (2.78 km/h), F5 (5.35 km/h), F7 (7.98 km/h), and F8 (9.75 km/h). Aspects of the gear-strength such as bending stress, contact stress, and safety factors were analyzed under two torque conditions: the equivalent torque at the highest plow load for the F8 speed stage and the maximum engine torque. The simulation results using KISSsoft showed that the maximum engine torque conditions had a lower safety factor than did the highest equivalent torque condition. The bending safety factors were > 1 at all gear stages, indicating that gear breakage did not occur under actual measured operating conditions, nor under the maximum torque conditions. However, the equivalent torque condition in the contact stress safety factor was > 1, and the maximum torque condition was < 1 at the first gear pair. The method of analysis using the equivalent torque showed lower stress and higher safety factor than did the method using maximum torque. Therefore, when designing a tractor by applying actual working torque, equivalent torque method would support more reliable product development.

A Novel Detection Algorithm for Instantaneous Voltage Sag Corrector Using Series Compensator

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.502-507
    • /
    • 2001
  • This paper proposes a novel detection algorithm of faulted voltages under the unbalanced condition. To quantify the standard of unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (MF). It is analyzed that MF and UF values are given as the dc constant values even though unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

  • PDF

SOME RESULTS ON FRACTIONAL n-FACTOR-CRITICAL GRAPHS

  • Yu, Jiguo;Bian, Qiuju;Liu, Guizhen;Wang, Na
    • Journal of applied mathematics & informatics
    • /
    • v.25 no.1_2
    • /
    • pp.283-291
    • /
    • 2007
  • A simple graph G is said to be fractional n-factor-critical if after deleting any n vertices the remaining subgraph still has a fractional perfect matching. For fractional n-factor-criticality, in this paper, one necessary and sufficient condition, and three sufficient conditions related to maximum matching, complete closure are given.