• 제목/요약/키워드: condensed water

검색결과 168건 처리시간 0.026초

Use of Chemical Treatments to Reduce Tannins and Trypsin Inhibitor Contents in Salseed (Shorea robusta) Meal

  • Mahmood, S.;Khan, Ajmal M.;Sarwar, M.;Nisa, M.;Lee, W.S.;Kim, S.B.;Hur, T.Y.;Lee, H.J.;Kim, H.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권9호
    • /
    • pp.1462-1467
    • /
    • 2007
  • This study investigated the effect of chemical treatments on tannins (condensed and hydrolysable) and on the trypsin inhibitor (TI) activity in salseed meal. Triplicate samples of ground salseed meal (1 kg) were mixed with 820 ml of either distilled water (pH 5.3), 0.67 M acetic acid (pH 2.4), 0.67 M sodium bicarbonate (pH 8.2) or 2% polyvinyl-pyrrolidone (PVP) solution. The material was placed in airtight plastic containers and incubated at $37^{\circ}C$ for 0, 3, 6, 12, 24, 48 and 72 h. Samples of untreated salseed meal which had not been subjected to soaking or incubation were run through the analysis to serve as control. Addition of water, acetic acid, sodium bicarbonate and PVP solutions to salseed meal and subsequent anaerobic incubation at $37^{\circ}C$ significantly reduced chemically detectable tannins. At each incubation time, alkali solution was more effective than its counterparts. The effect of acidic solution on hydrolysable tannin was least among the treatments. All the treatments reduced TI activity of salseed meal. The reduction in TI activity by these treatments was similar and ranged between 80-84%. Treatment time effected a decrease in the contents of antinutritional substances. However, the effect of the treatment with the reagents, even for zero incubation time, was quite pronounced. It may be concluded from the present results that the treatment of salseed meal with sodium bicarbonate (0.67 M) is more effective in reducing hydrolysable and condensed tannin contents than PVP, water and acid solutions. Treatment with sodium bicarbonate solution is more economical and easier to handle than acid and PVP treatments. Incubation of the treated material for 12 h is reasonably effective, economical and safe from any mould growth.

음식물류폐기물의 건식사료화 공정에서 발생되는 응축수로부터 유기탄소 추출 (Extraction of organic carbon from the condensate of food waste dry feed process)

  • 김민경;권기욱;모경;최봉호;박세용;김문일
    • 유기물자원화
    • /
    • 제28권2호
    • /
    • pp.41-48
    • /
    • 2020
  • 본 연구에서는 음식물류폐기물 건조공정에서 발생하는 응축수에 포함된 유기탄소를 추출하여 외부탄소원으로서 적용 가능성을 평가하였다. 응축수의 성상은 COD, TN, TP 및 TS는 각각 21,374 (±3,238.3) mg/L, 148 (±32.6) mg/L, 4.19 (±1.5) mg/L, 455.7 (±0.015) mg/L로 나타났으며, 응축수에 포함된 생분해성 유기물의 함량은 47%였다. 응축수에 포함된 유기탄소 추출을 위하여 증발 농축 및 감압 증발 농축의 방법을 사용하였다. 본 연구에서 총 8가지 조건에서 수행 되었으나, 4가지 조건 (1. 상압 (0mmHg), 110℃ 2. 감압 (-600mmHg), 70℃ 3. 감압 (-500mmHg), 80℃ 4. 감압(-600mmHg), 80℃)에서 추출이 가능한 것으로 나타났다. 추출 결과, 추출된 4가지 조건 모두에서 유입 부피의 약 10% 추출하였을 때, 추출물의 유기물 농도가 가장 높고 추출 시간 대비 추출된 유기물의 양이 가장 많은 것으로 나타났다. 응축수에 포함된 유기탄소의 추출 최적 조건은 감압 (-600mmHg), 80℃로 판단하였으며, 유입 부피의 10% 추출이 적합한 것으로 평가하였다. 이때, 추출 농도, 추출량, 추출 효율, 추출시간, BOD/TCOD, TVFAs/TCOD의 비율 및 NH3-N의 값은 각각 174,200 mg/L, 8,710 mg, 46%, 10분, 0.97, 0.74, 75.5 mg/L로 나타났다. 따라서, 추출된 유기탄소는 외부탄소원으로 활용될 수 있을 것으로 판단된다.

음식물 소멸기에서 발생하는 응축폐수의 Polyethylene 침지형 중공사막을 이용한 처리 특성 (Processing Characteristics of the Condensed Wastewater Resulting from Food Waste Disposal using a Submerged Polyethylene Hollow Fiber Membrane)

  • 유재상;전태봉;김진호;정건용
    • 멤브레인
    • /
    • 제20권2호
    • /
    • pp.127-134
    • /
    • 2010
  • 연구는 음식물 쓰레기를 음식물 소멸기에서 미생물에 의해 발효하여 유기물을 감량화하고, 음식물 발효시 발생되는 가스를 냉각기에서 기체와 수분으로 분리하여 기체는 반응기로 다시 보내고 수분은 응축하여 침지식 MF 중공사 분리막이 장착된 MBR 시스템에 적용하여 처리하는 시스템에 관한 연구이다. (주)바이오하이테크에서 제작한 음식물 소멸기와 수처리 장치에 침지식 MF 중공사 모듈을 설치하여 90일간 H연구소 직원식당에서 발생되는 음식물 쓰레기를 연속 투입하여 처리하였다. 음식물 소멸기 초기 Seeding를 위하여 수분조절제로 미강, 왕겨, 톱밥을 305 kg 투입하였고 음식물은 운전기간동안 1,648 kg투입하였고 응축폐수는 1,600 L 발생되었다. 음식물 소멸기 운전 종료 후 배출된 발효 부산물은 386 kg으로 감량율은 약 80%로 조사되었다. 침지식 MF 중공사 분리막 모듈을 응축폐수의 MBR 시스템에 적용하여 유기물 처리한 결과 제거율은 각각 BOD 99.9%, COD 97.5%, SS 98.6%, T-N 54.6%, T-P 34.7%였으며, 총대장균은 100%가 제거되었다.

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.

Angular Dispersion-type Nonscanning Fabry-Perot Interferometer Applied to Ethanol-water Mixture

  • Ko, Jae-Hyeon;Kojima, Seiji
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.261-266
    • /
    • 2009
  • The angular dispersion-type non-scanning Fabry-Perot was applied to an ethanol-water mixture in order to investigate its acoustic properties such as the sound velocity and the absorption coefficient. The scattered light from the mixture was analyzed by using the charge-coupled-device area detector, which made the measurement time much shorter than that obtained by using the conventional scanning tandem multi-pass Fabry-Perot interferometer. The sound velocity showed a deviation from ultrasonic sound velocities at low temperatures accompanied by the increase in the absorption coefficient, indicating acoustic dispersion due to the coupling between the acoustic waves and some relaxation process. Based on a simplified viscoelastic theory, the temperature dependence of the relaxation time was obtained. The addition of water molecules to ethanol reduced the relaxation time, consistent with dielectric measurements. The present study showed that the angular dispersion-type Fabry-Perot interferometer combined with an area detector could be a very powerful tool in the real-time monitoring of the acoustic properties of condensed matter.

고효율 응축형 열교환기 개발에 관한 연구 (A study on the development of the high efficiency condensing heat exchanger)

  • 이금배;박상일;박준태
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

Polymer Supported Cyanide as an Efficient Catalyst in Benzoin Condensation: An Efficient Route to α-Hydroxy Carbonyl Compounds

  • Kiasat, Ali Reza;Badri, Rashid;Sayyahi, Soheil
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권5호
    • /
    • pp.1164-1166
    • /
    • 2009
  • Aromatic aldehydes are efficiently self-condensed into $\alpha$-hydroxy carbonyl compounds by polystyrene-supported ammonium cyanide as an excellent organocatalyst in C-C bond formation. The reaction proceeds in water under mild reaction conditions. The polymeric catalyst can be easily separated by filtration and reused several times without appreciable loss of activity.

Superhydrophobic Surfaces for condensation by using spray coating method

  • Oh, Seungtae;Seo, Donghyun;Lee, Choongyeop;Nam, Youngsuk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.157.2-157.2
    • /
    • 2016
  • Water repellent surfaces may enhance the condensation by efficiently removing the condensed droplets. However, such surfaces may lose their original performance as they are exposed to external mechanical stresses. In this work, we fabricated spray-coated mechanically robust superhydrophobic surfaces using treated titanium dioxide (Type 1) or silica particles (Type 2). Then we compared the mechanical robustness of such surfaces with the silane-coated superhydrophobic surface and PEEK coated surface using a controlled-sand blasting method. The results show that the spray-coated samples can maintain the same level of the contact angle hysteresis than silane-coated superhydorphobic surface after sand blasting at 2 bar. The spray-coating method was applied to the tube type condenser and the condensation behaviors were observed within the environmental chamber with controlled pressure, humidity and non-condensable gas. Previously-reported droplet jumping was observed in the early stage of the condensation event, but soon the droplet jumping stopped and only dropwise condensation was observed since the condensed droplets were pinned on the cracks at spray-coated surfaces. The static contact angle decreases from $158.0^{\circ}$ to $133.2^{\circ}$, and hysteresis increases from $3.0^{\circ}$ to $23.5^{\circ}$ when active condensation occurs on such surfaces. This work suggests the benefits and limitation of spray-coated superhydrophobic condensers and help develop advanced condensers for practical use.

  • PDF

총 인 분석을 위한 자동 전처리 시스템 (Automated On-Line Digestion System for the Determination of Total Phosphorus)

  • 정형근;조영일;김범식;박주형
    • 한국환경과학회지
    • /
    • 제10권1호
    • /
    • pp.13-19
    • /
    • 2001
  • An on-line digestion system based on the flow injection analysis technique was presented for the determination of total phosphorus. The system converts condensed and organic phosphoruses into orthophosphate that can be analyzed spectrophotometically. The reaction between orthophosphate and ammonium molybdate in a strong acid medium forms the yellow complex of phosphomolybdate which is next reduced to a molybdic blue complex by stannous chloride. The quantitation of orthophosphate is based on the absorbance of the molybdic blue. To determine total phosphorus, the digestion system was installed between the sample injector and the reaction coil with the added lines of digestion solution(potassium persulfate+sulfuric acid) and the $H_2O$ carrier. The system has shown that the digestion efficiencies were greater than 95% for the typical condensed and organic phosphoruses. When tripolyphosphate standards were used, the calibration data showed that the linear dynamic range extended to a concentration of 1.5ppm with the detection limit of 25ppb total phosphorus. The typical relative standard deviation was less than 2%. The proposed system was successfully applied to lake water, wastewater, and streamwater. The analytical variables such as digestion efficiency, analysis time, and reproducibility were evaluated and compared with the manual digestion method.

  • PDF

일사량과 경사진 육면체 내부의 온도변화에 따른 응축특성에 관한 정량적 연구 (Quantitative Analysis of the Condensation Characteristics with Solar Radiations and Inner Temperature of the Tilted Box)

  • 이춘기;고영하;김병철
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.44-50
    • /
    • 2011
  • The solar radiation, inner temperature of the tilted box and the amount of condensed water were measured to find the most effective purified water production system. The inner temperature of the tilted box was related with solar radiation that was affected by sunshine and cloud. With analyzing those relationships of the solar radiation, inner box temperature, the angle of tilted boxes and amounts of water condensation optimal collecting system area could be calculated.