설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

탄화수소계 냉매의 응축 압력강하에 관한 연구 (Study on Condensing Pressure Drop of Hydrocarbon Refrigerants)

  • 김재돌;최준혁;정석권;윤정인;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.218-224
    • /
    • 2006
  • Experimental results for pressure gradient of HCs refrigerants R-290. R-600a. R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have the tube inner diameter of 10.98mm. and the tube inner diameter of 8mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in both test sections with the diameters of 12.70mm and 9.52mm. Pressure drop increased with the increase of the mass flux. These results form the investigation can be used in the design of heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems

첨가제 종류에 따른 탄소나노튜브 금속복합재료 소결코팅 영향 (Influences to Additive Type on Carbon Nanotube metal composite)

  • 김대해;정희여;김민수;박찬우
    • Composites Research
    • /
    • 제25권5호
    • /
    • pp.159-163
    • /
    • 2012
  • 냉매의 비등이나 응축같은 열전달 향상을 위하여 금속 표면위에 탄소나노튜브(CNT)를 코팅하는 것을 연구하였다. 분산제와 PVA(polyvinyl alcohol) 용액으로 분산 처리된 다중벽 탄소나노튜브/CuO의 복합 분말 코팅액을 구리기판위에 도포한 후 소결을 하였다. 본 논문에서는 CNT/CuO 소결 코팅시 다양한 분산제를 사용하여 소결 전후의 조직 형상 변화 및 특징을 실험적으로 평가하였다. 분산제로는 THF(Tetrahydrofuran), SDBS(Dodecylbenzenesulfonic acid sodium salt), SDS(Sodium dodecy sulfate)가 사용되었다. 각각의 시편들은 주사전자현미경, 열중량분석, 시차주사열량측정법, 라만분광법을 사용하여 분석하였다.

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

응축을 수반하는 분무수적으로의 열 및 질량전달률 예측 (Predictions of Heat and Mass Transfer Rates to a Spray Droplet Experiencing Condensation)

  • 이상균;조종철;신원기;조진호;서정일
    • 대한기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1763-1773
    • /
    • 1991
  • 본 연구에서는 포화수증기와 공기의 혼합기내에서 분무수적으로의 열 및 질량 전달률을 계산하기 위하여 수적의 부분혼합모형과 비혼합모형에 대하여 수적내 과도온 도분포의 해석해를 적용성이 보장되면서도 계산상의 어려움이 수반되지 않는 형태로 구하기 위하여 수적내부의 열전도해석에 있어서 적분법을 적용하였다. 적분법으로 얻어지는 과도온도분포의 해는 유한차의 다항식으로 표시되어 비혼합모형인 경우 각시 간 구간의 경계에서의 온도분포가 연속성을 유지하면서 물성치들의 온도에 대한 종속 성이 쉽게 고려되고 계산도 용이한 형태이다. 본 보에서 제시하는 해석결과의 적용 성을 조사하기 위하여 완전혼합모형을 포함하는 세가지 수적모형들에 대한 계산결과들 로부터 얻어진 시간변화에 따른 수적의 무차원 체적평균온도변동을 유효한 실험결과들 과 비교, 검토하였으며, 부분혼합모형에 대하여 혼합기의 압력, 수적의 초기온도, 혼 합기 속에 포함되어 있는 수증기의 체적분율, 수적의 초기크기, 수적의 초기속도 및 분사각도가 주위혼합기로부터 수적으로 전달되는 열 및 질량전달에 미치는 영향을 조] 사하고 도출된 대표적인 검토 결과를 제시하였다.

Assessment and Improvement of Condensation Models in RELAP5/MOD3.2

  • Choi, Ki-Yong;Park, Hyun-Sik;Kim, Sang-Jae;No, Hee-Cheon;Bang, Young-Seok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.585-590
    • /
    • 1997
  • The condonation models in the standard RELAP5/MOD3.2 code are assessed and improved based on the database, which is constructed from the previous experimental data on various condonation phenomena The default model the laminar film condonation in RELAP5/MOD3.2 does not give any reliable predictions, and its alternative model always predicts higher values than the experimental data Therefore, it is needed to develop a new correlation based on the experimental data of various operating ranges in the constructed database. The Shah correlation, which is used to calculate the turbulent film condensation heat transfer coefficients in the standard RELAP5/MOD3.2, well predicts the experimental data in the database. The horizontally stratified condonation model of RELAP5/MOD3.2 overpredicts both cocurrent and countercurrent experimental data The correlation proposed by H.J.Kim predicts the database relatively well compared with that of RELAP5/MOD3.2 The RELAP5/MOD3.2 model should use the liquid velocity for the calculation of the liquid Reynolds number and be modified to conifer the effects of the gas velocity and the film thickness.

  • PDF

가정용 빌트인 제빙기의 분무 노즐, R-404A 충전량 최적화 및 제빙 가시화 (Optimization of Spray Nozzle, R-404A Charge Amount and Visualization of Ice Formation in a Residential Built-in Ice Maker)

  • 김내현;김현진
    • 설비공학논문집
    • /
    • 제29권8호
    • /
    • pp.437-445
    • /
    • 2017
  • Because of improvement of living standards and increased use of ice at home, built-in ice makers are of interest. In this study, refrigeration cycle of a unitary ice maker for residential usage was optimized using R-404A. Optimization was achieved through a search for proper refrigerant charge amount. For the present ice maker producing ice for 24 cups, the optimum charge amount was 200 g. In this configuration, the ice making cycle time was 17 minutes 53 seconds, ice production was 1.27 kg/h and COP was 0.310. After initial start-up, condensation and evaporation temperatures gradually decreased with time. As ice builds in the cup, heat transfer performance of the evaporator decreases, that results in decrease of evaporation and condensation temperatures. Replacement of existing slit nozzles with individual circular hole nozzles improved ice production capacity by 10 percent. Through visualization of ice formation in the ice cup, growth rate of the ice in the cup was relatively uniform.

세관을 사용한 응축기에서 R-22의 대체냉매인 R-410A의 응축 열전달 특성 (Condensation Heat Transfer Characteristics of R-410A as an Alternative R-22 in the Condenser with Small Diameter Tubes)

  • 손창효
    • 청정기술
    • /
    • 제13권2호
    • /
    • pp.151-158
    • /
    • 2007
  • 프레온계 냉매의 지구온난화와 오존층파괴 문제로 인해 대체냉매로서 R-410A가 주목을 받고 있다. 이러한 대체냉매를 세관에 적용시킬 경우 효율을 향상시킬 뿐만 아니라 지구환경에 미치는 영향을 감소시키고, 대기를 청정하게 만드는 기술 및 방안으로 각광 받고 있다. 따라서 본 연구에서는 R-22의 대체냉매로 각광받고 있는 R-410A의 세관응축기 내에서의 응축열전달 특성에 대해 실험적으로 고찰하고자 하였다. 실험장치는 유동양식, 열전달, 압력강하 특성을 파악할 수 있도록 제작되었고, 주요 구성품은 냉매펌프, 증발기, 응축기(시험부), 사이트 글라스(가시화부), 압력탭, 측정장치 등이다. 시험부의 내관은 내경 3.36 mm와 5.35 mm인 수평평활 동관이다. 실험변수들의 범위로서 질량유속 $200{\sim}500\;kg/m^2s$이고, 열유속은 $1.0{\sim}2.4\;kW$이다. R-410A의 응축열전달 계수가 R-22에 비해 최대 5% 정도 높은 것을 알 수 있었다. 세관 내 R-410A와 R-22의 유동양식은 환상류 영역이 지배적으로 나타남을 관찰하였고, 건도가 0.2 이하인 영역에서는 성층류가 나타남을 확인할 수 있었다. 내경 3.36 mm의 압력강하가 내경 5.35 mm에 비해 $30{\sim}50%$정도 높았다. 종래의 응축 열전달 상관식과 실험데이터를 비교한 결과, Fujii의 상관식과 최대 40%이내에서 일치하였다.

  • PDF

순산소 전로의 증기드럼 내의 3차원 열 유동 해석모델 개발 (Development of Three-dimensional Thermo-fluid Numerical Model for Steam Drum of a Basic Oxygen Furnace)

  • 정수진;문성준;장원준;고순탁;곽호택
    • Korean Chemical Engineering Research
    • /
    • 제54권4호
    • /
    • pp.479-486
    • /
    • 2016
  • 순산소 전로 후드의 일산화탄소와 열회수를 위해서는 고효율의 증기를 발생시키는 증기드럼의 장착이 필요하다. 그러나 제선 제강공정에서 증기발생은 간헐적이거나 주기적인 산소 취입공정기간에 제한적이다. 따라서, 증기드럼은 전로의 주기에 따른 산소의 취련기간 동안 효율적으로 증기를 발생시키도록 최적 설계되어야 한다. 따라서 본 연구에서는 다양한 운전조건 및 기하학적 형상변화가 증기드럼 내의 열유동 특성과 성능에 미치는 효과를 예측할 수 있는 3차원 전산유체역학 모델을 제안하였다. 본 모델은 유체유동 및 열전달 뿐만 아니라 계면유동에서의 증발 및 응축을 유한체적법을 사용하여 고려하였다. 본 모델의 예측성능을 검증하기 위하여 실험에서 구한 증기발생량과 비교하였으며 3.2%의 상대오차를 보였다.

응축방식을 이용한 담수화 시스템의 성능예측을 위한 분석연구 (An Analytical Study on the Performance Analysis of a Desalination System by Condensing Method)

  • 김철호;김원일;최재영;김재철;김민선
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제2권1호
    • /
    • pp.47-55
    • /
    • 2014
  • 본 연구에서는 태양열에 의해 증발된 해수면에서의 수증기를 응축의 원리를 이용하여 담수의 생산이 가능한 친환경 담수장치(Eco-friendly Desalination System)를 고안하고, 가능성을 판단하는데 연구의 목적을 두고 있다. 응축 열전달 공식을 이용하여 습공기의 물성변화에 따른 연간 응축수 생산량을 예측하였으며, 항온항습챔버의 실험을 통해 실제 습공기조건 변화에 따른 응축량을 측정하였다. 습공기의 이론 응축률과 실험을 통해 측정한 실제 응축률의 오차율을 산출하였으며, 오차의 원인을 분석하고 응축률 보정계수인 응축계수와 점성계수를 구하여 보정된 이론 응축률 공식에 도출하였다. 보정된 응축률 식을 이용하여 설계된 규모의 풍력터빈연간 생산 가능한 담수량을 산출한 결과 최대 연간 약 2,927톤 정도의 담수를 생산할 수 있다는 사실을 알 수 있었다.