DOI QR코드

DOI QR Code

Optimization of Spray Nozzle, R-404A Charge Amount and Visualization of Ice Formation in a Residential Built-in Ice Maker

가정용 빌트인 제빙기의 분무 노즐, R-404A 충전량 최적화 및 제빙 가시화

  • Received : 2017.05.15
  • Accepted : 2017.07.12
  • Published : 2017.08.10

Abstract

Because of improvement of living standards and increased use of ice at home, built-in ice makers are of interest. In this study, refrigeration cycle of a unitary ice maker for residential usage was optimized using R-404A. Optimization was achieved through a search for proper refrigerant charge amount. For the present ice maker producing ice for 24 cups, the optimum charge amount was 200 g. In this configuration, the ice making cycle time was 17 minutes 53 seconds, ice production was 1.27 kg/h and COP was 0.310. After initial start-up, condensation and evaporation temperatures gradually decreased with time. As ice builds in the cup, heat transfer performance of the evaporator decreases, that results in decrease of evaporation and condensation temperatures. Replacement of existing slit nozzles with individual circular hole nozzles improved ice production capacity by 10 percent. Through visualization of ice formation in the ice cup, growth rate of the ice in the cup was relatively uniform.

Keywords

References

  1. Park, H.-C., 2002, Development of 100 kg/day Ice Maker Using Alternative Refrigerants R-404A, Final Report to ITEP, Basic Industrial Technology Development Program, Se-A E&C.
  2. Mishchenko, L., Hatton, B., Bahadur, V., Taylor, J. A., Krupenkin, T., and Aizenberg, J., Design of Ice-Free Nanostructured Surfaces Based on Repulsion of Ice Droplet, ACS Nano, Vol. 4, No. 12, pp. 7699-7007. https://doi.org/10.1021/nn102557p
  3. Jin, Z., Wang, Z., Sui, D., and Yang, Z., 2016, The Impact and Freezing Process of a Water Droplet on Different Inclined Cold Surfaces, Int. J Heat Mass Trans., Vol. 97, pp. 211-213. https://doi.org/10.1016/j.ijheatmasstransfer.2016.02.024
  4. Feuillebois, A., Lasek, A., Creismeas, P., Pigeonneau, F., and Szaniawski, A., 1995, Freezing of a Subcooled Liquid Droplet, J. Colloid. Sci., Vol. 169, No. 1, pp. 90-102. https://doi.org/10.1006/jcis.1995.1010
  5. Sait, H. H., 2013, Heat Transfer Analysis and Effects of Feeding Tube Arrangement, Falling Film Behavior and Backslpash on Ice Formation Around Horizontal Tube Bundles, Energy Conv. Manage., Vol. 73, pp. 317-328. https://doi.org/10.1016/j.enconman.2013.05.010
  6. Jung, E.-H. and Park, K.-W., 2009, Ice Making Characteristics According to Changing Shape of Ice Making Tube, Korean J. Air-Cond. Refrig., Vol. 21, No. 5, pp. 291-296.
  7. Jannesari, H. and Abdollahi, N., 2017, Experimental and Numerical Study of Thin Ring and Annular Fin Effects on Improving the Ice Formation in Ice-on-Coil Thermal Storage Systems, Appl. Energy, Vol. 189, pp. 369-384. https://doi.org/10.1016/j.apenergy.2016.12.064
  8. Kulyakhtin, A., Kulyakhtin, S., and Loset, S., 2016, The Role of the Ice Heat Conduction in the Ice Growth Caused by Periodic Sea Spray, Cold Regions Sci. Tech., Vol. 127, pp. 93-108. https://doi.org/10.1016/j.coldregions.2016.04.001
  9. UNEP, 1987, Montreal Protocol on Substances That Deplete the Ozone Layer, United Nation Environmental Programme.
  10. Arora, A. and Kaushik, S. C., 2008, Theoretical Analysis of a Vapor Compression Refrigeration System with R-502, R-404A and R-507A, Int. J. Refrig., Vol. 31, No. 6, pp. 998-1005. https://doi.org/10.1016/j.ijrefrig.2007.12.015
  11. REFPROP, NIST Reference Fluid Thermodynamic and Transport Properties Database (REFPROP) : Version 9.1, https://www.nist.gov/srd/refprop/.
  12. Stoecker, W. F. and Jones, J. W., 1983, Refrigeration and Air Conditioning, 2nd Ed., McGraw-Hill Pub.
  13. ASHRAE Standard 29, 2009, Method of Testing Automatic Ice Makers, ASHRAE.