• Title/Summary/Keyword: condensation heat transfer

Search Result 338, Processing Time 0.027 seconds

Physical Model and Numerical Simulation Approach of Steam Flow and Heat Transfer of Pannier-arrangement Condensers

  • Hou, Pingli;Yu, Maozheng
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.109-116
    • /
    • 2004
  • Through analysing the influence of steam flow direction on the liquid formation and motion behavior in the condenser shell side, the physical model for existing numerical simulation program of condenser is improved by introducing the correlations for flow resistance and condensation heat exchange coefficient in which the influences of steam flow direction are considered according to the available experimental data. Thus a more suitable and general condenser simulation approach is presented and a new condenser calculation program is developed. With the experimental data of a pannier- arrangement experimental condenser, the adaptability of the new condenser simulation approach is verified. General characteristics of this type of condenser are also revealed.

  • PDF

An Study on Efficiency and Application of Thermal Siphon in the Permafrost (영구동토 지대에서 Thermal Siphon의 효율성 연구)

  • Kang, Jae-Mo;Kim, Hak-Seung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.963-966
    • /
    • 2009
  • A Construction of pipe line foundation and railroad, buildings in a permafrost area requires engineering technology of ground stabilization. In the permafrost area, thermal siphons have been used to stabilize foundation by eliminating the heat of ground to the air. the thermal siphon is a passive heat transfer device that operates by convection through vaporization and condensation. The heat transfer from ground to the air is driven by a temperature difference across the unit. A buried part in ground working as vaporizing function and upper part work as condensing. In this study, buried thermal siphon around the pipe lines laid in the Vladivostok site and measuring temperature variation. It is found that the thermal siphons freezing ground faster and decrease temperature variation in winter season.

  • PDF

A study on the application Heat Pump to Rolling Stock Air conditioner (히트펌프식 냉난방장치의 철도차량 적용에 관한 연구)

  • Kweon, Tae-Kyun;Song, Young-Jeong;Jeong, Gwang-Moo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1689-1696
    • /
    • 2008
  • Heat pumps transfer heat by circulating a substance called a refrigerant through a cycle of evaporation and condensation. But Heat pumps system by only using heat-source is not efficient. Because the mean temperature of North Korean winter season is low, economy of air heat-source heat pump descend. This paper is practiced the simulation on evaluation criteria for Heat pump heating and cooling systems to Rolling Stock. Efficiency of the heat pump in order improving from certainly the development of the technique will be able to prevent a freezing actual condition must proceed. As a result, Below $-10^{\circ}C$ used heating and cooling systems of heat pump format even in cold winter season and is serviceable confirmed with heat source supply circle of the Rolling Stock.

  • PDF

Assessment of RELAP5/MOD3.2 with Condensation Experiment in the Presence of Noncondensables in a Vertical Tube

  • Park, Hyun-Sik;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.547-552
    • /
    • 1998
  • The standard RELAP5/MOD3.2 code were assessed with the condensation experiment in the presence of noncondensable gas in a vortical tube of PCCS of CP-1300. There are two wall film condensation models, the default model and the alternative model, in RELAP5/MOD3.2. The experimental apparatus was modeled with the two models, md simulations were performed for several sub-tests to be compared with the experimental results. In overall sense the simulation results showed that the default model of RELAP5/MOD3.2 under-predicts the heat transfer coefficients, while the alternative model over-predicts them throughout the condensing tube.

  • PDF

A Comparison of Flow Condensation HTCs of R22 Alternatives in the Multi-Channel Tube (알루미늄 다채널 평판관내 R22의 흐름응축 열전달 성능 비교)

  • Seo, Young-Ho;Lim, Dae-Taeg;Park, Ki-Jung;Jung, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1270-1275
    • /
    • 2004
  • Flow condensation heat transfer coefficients(HTCs) of R22 and R134a were measured on horizontal aluminum multi-channel tube. The experimental apparatus was composed of three main parts ; a refrigerant loop, a water loop and a water-ethylene glycol loop. The test section in the refrigerant loop was made of aluminum multi-channel tube of 1.4 mm hydraulic diameter and 0.53 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. The data scan vapor qualities $(0.1{\sim}0.9)$, mass flux ($200{\sim}400$ $kg/m^{2}s$) and heat flux ($7.3{\sim}7.7$ $kW/m^{2}$) at $40{\times}0.2^{\circ}C$ saturation temperature in small hydraulic diameter tube. It was found that some well-known previous correlations were not suitable for multichannel tube. So, It must develop new correlations for multi-channel tubes.

  • PDF

Reconsideration of the Azimuth Functions in the Analysis of Heat Transfer by the Method of Similarity Transformations (상사변환법에 의한 열전달해석에 있어서 방위함수의 재고)

  • ;;Son, Byung Jin;Yi, Hyun
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.3 no.3
    • /
    • pp.91-97
    • /
    • 1979
  • Boundary layer equations (partial differential equations) can be transformed to ordinary diffential equations with constant coeffieients in terms of similarity transformed to ordinary differential equations with constant coeffieients in terms of similarity transformations in the heat tranfer analysis on the surface of any axiaymmetric boiles. The azimuth functions can not be uniquely determined because of the singular behavior at the stagnation point(X=0.deg.).In spite of the azimuth functions behaving singularly, many of researchers have analyzed the heat transfer problem on a horizontal chlinder or a sphere, supposing the set of solutions( $H_{1}$ & G$_{1}$) of being yieled from the simple differential equation to be unique solution of therazimuth functions. In order to ascertain whether mathematical incompatibility as mentioned above can be admitted in the viewpoint of enginerring or not, condensation heat transfer coefficients on a sphere are computed for all azimuth functions( $H_{1}$ G$_{1}$ & $H_{2}$ G$_{2}$) and comparisons with the experimental result are discussed.

Numerical analysis of an air-cooled ammonia condenser with plate fins (평판핀이 부착된 공냉형 암모니아 응축기의 열전달 성능에 대한 수치적 연구)

  • Kim, Y.I.;Kang, B.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.292-299
    • /
    • 1997
  • Ammonia has been used as refrigerant for more than 100 years in absorption as well as in compression systems. Due to its poisonous and inflammable properties, however, its use has been mainly on heavy industrial plants in which regular maintenance are available. For these systems, condensers are generally water-cooled. This is suitable for large systems over 20 RT but is not suitable for small systems. In order to apply ammonia for a small system, it is important to adopt an air-cooled condenser. In this study, simple numerical analysis of an air-cooled condenser for an ammonia refrigeration system has been carried out. The condenser is designed as horizontal tubes with plate fins attached at the outer surface to enhance the air-side heat transfer rate. Effects of fin shape and arrangement are studied in detail. Since the local heat transfer coefficient is highest at the leading edge, heat flux is highest at the edge and decreases along the distance. Conditions of inlet air are also varied in the study and condenser length that is required for full condensation is calculated. The results show that it is important to enhance both the air-side and internal heat transfer coefficients.

  • PDF

Numerical Analysis of an Air-cooled Ammonia Condenser with Plate Fins

  • Kim, Young-Il;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.104-112
    • /
    • 1998
  • Ammonia has been used as refrigerant for more than 100 years in absorption as well as in compression systems. Due to its poisonous and inflammable properties, however, its use has been mainly on heavy industrial plants in which regular maintenance is available. For these systems, condensers are generally water∼cooled. This is suitable for large systems over 20RT but is not suitable for small systems. In order to apply ammonia for a small system, it is important to adopt an air-cooled condenser. In this study, simple numerical analysis of an air-cooled condenser for an ammonia refrigeration system has been carried out. The condenser is designed as horizontal tubes with plate fins attached at the outer surface to enhance the air-side heat transfer rate. Effect of fin shape and arrangement are studied in detail. Since the local heat transfer coefficient is highest at the leading edge, heat flux is highest at the edge and decreases along the distance. Conditions of inlet air are also varied in the study and condenser length that is required for full condensation is calculated. The results show that it is important to enhance both the air-side and internal heat transfer coefficients.

  • PDF

Effect of Aspect Ratio of Flat Tube on R410A Evaporation Heat Transfer and Pressure Drop (납작관의 종횡비가 R-410A 증발열전달 및 압력손실에 미치는 영향)

  • Kim, Nae Hyun;Lee, Eul Jong;Byun, Ho Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.395-404
    • /
    • 2013
  • In this study, R-410A evaporation heat transfer tests were conducted in flattened tubes made from 5-mm round tubes. The test range covered a saturation temperature of $15^{\circ}C$, heat flux of $5{\sim}15kW/m^2K$, and mass flux of $200-400kg/m^2s$. The results showed that both the condensation heat transfer coefficient and the pressure drop increased as the aspect ratio increased, with a pronounced increase for an aspect ratio of 4. A comparison of the flattened tube data with existing correlations revealed that the heat transfer coefficients were reasonably predicted by the Shah correlation, and the pressure drops were reasonably predicted by the Jung and Radermacher correlation.

SEPARATE AND INTEGRAL EFFECT TESTS FOR VALIDATION OF COOLING AND OPERATIONAL PERFORMANCE OF THE APR+ PASSIVE AUXILIARY FEEDWATER SYSTEM

  • Kang, Kyoung-Ho;Kim, Seok;Bae, Byoung-Uhn;Cho, Yun-Je;Park, Yu-Sun;Yun, Byoung-Jo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.597-610
    • /
    • 2012
  • The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+, which is intended to completely replace the conventional active auxiliary feedwater system. With an aim of validating the cooling and operational performance of PAFS, an experimental program is in progress at KAERI, which is composed of two kinds of tests; the separate effect test and the integral effect test. The separate effect test, PASCAL ($\underline{P}$AF$\underline{S}$ $\underline{C}$ondensing Heat Removal $\underline{A}$ssessment $\underline{L}$oop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in PAFS. A single, nearly-horizontal U-tube, whose dimensions are the same as the prototypic U-tube of the APR+ PAFS, is simulated in the PASCAL test. The PASCAL experimental result showed that the present design of PAFS satisfied the heat removal requirement for cooling down the reactor core during the anticipated accident transients. The integral effect test is in progress to confirm the operational performance of PAFS, coupled with the reactor coolant systems using the ATLAS facility. As the first integral effect test, an FLB (feedwater line break) accident was simulated for the APR+. From the integral effect test result, it could be concluded that the APR+ has the capability of coping with the hypothetical FLB accident by adopting PAFS and proper set-points of its operation.