• 제목/요약/키워드: concrete stress gauge

검색결과 19건 처리시간 0.022초

매스콘크리트구조물에서의 온도응력 측정기법에 관한 연구 (A Study on the Meassurement Technology of Thermal Stress in Massive Concrete Structure)

  • 강석화;정철헌;이용호;박칠림
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.71-76
    • /
    • 1994
  • Recently, constructions of huge reinforced concrete structures such as nuclear power stations have been increased. When massive concrete is placed, cracking due to the hydration heat of cement is recognized as a major problem. The development of thermal stress is influenced by the structure shape and the constraint conditions, and cracks usually occure from tensile stresses which developed due to temperature drop. In this study a protocol specimen is made to examine the distribution of temperature and thermal stress of reaction wall of Daewoo Institute Construction Technology. The size of the specimen is made by considering minimum size of real structure. In this study, concrete strain gauge, concrete stress gauge, concrete non-stress gauge, and thermocouples, are instrumented to measure thermal stress in massive concrete structure. A new measuring technique is proposed to calculate thermal stress.

  • PDF

매스콘크리트구조물의 온도응력평가에 관한 연구 (A Study on the Evaluation of Thermal Stress of Massive Concrete Structure)

  • 강석화;정철헌;정한중;이용호;박칠림
    • 콘크리트학회지
    • /
    • 제7권2호
    • /
    • pp.126-135
    • /
    • 1995
  • 온도균열은 시멘트의 수화열에 의한 온도응력이 콘크리트의 인장강도보다 커질 경우에 발생하는 균열로서, 구조물의 수밀성과 기밀성등에 중대한 영향을 미치기 때문에 매스콘크리트와 같이 단면이 큰 구조물의 설계 및 시공시에는 반드시 온도균열에 대한 배려가 필요하다. 본 연구에서는 모의실험체를 대상으로 하여 매스콘크리트의 경화시 발생하는 온도응력을 측정할 목적으로 콘크리트변형계와 무응력계 그리고 유효응력계등을 설치하여구조물 내부의 온도응력의 경시변화를 검토하고 콘크리트변형계를 이용한 온도응력 산정방법 및 문제점등에 대하여 검토하였다. 연구결과 콘크리트변형계와 무응력계를 이용한 새로운 온도응력 산정법을 제시하였으며, 그 결과 유효응력계의 측정치와 거의 일치하는 값을 얻을 수 잇었다. 이를 위해서는 무응력계 또는 이와 동일하게 초기재령시의 콘크리트 자기수축변형률을 측정할 수 있는 게이지의 설치가 전제가 되어야 하며, 초기재령시의 건조수축량에 대한 정량화가 가능하다면 콘크리트변형계를 이용한 온도응력의 산정도 충분히 가능하다는 것을 알 수 있다.

매스콘크리트의 수화열 해석 및 현장 계측을 통한 수화발열량차 공법의 현장적용성 (Field Application of Foundation Mass Concrete Applying Hydration Heat Differential Method and Insulation Curing Method)

  • 한준희;임군수;신세준;전충근;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.229-230
    • /
    • 2023
  • In this study, the hydration heat differential method was applied to mass concrete structures, and the hydration heat analysis was compared and analyzed with on-site measurement results. The results showed that the temperature history measurements of mass concrete were managed at a difference of 8.4 ℃, and although there was some deviation in thermal stress, a similar trend was observed. Consequently, it was determined that the thermal stress on the surface of mass concrete is less than its tensile strength, which would prevent the occurrence of thermal cracks.

  • PDF

댐 거동 분석에서의 Strain Gauge를 이용한 단일 계측에 관한 연구 (The Study on the Simple Measurement by Using the Strain Gauge at Dam Dynamic Behavior Analysis)

  • 이승호
    • 한국지반환경공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.5-11
    • /
    • 2007
  • 담수시 저수되는 수압에 의해 face slab con'c 내부의 응력변화가 발생하여 댐 제체의 안정성에 영향을 미칠 가능성이 있으므로 face slab con'c의 내부 응력변화를 측정하기 위하여 매립형 strain gauge가 많이 적용되고 있다. 따라서 본 연구에서는 ${\circ}{\circ}$댐에 적용된 strain gauge를 이용하여 댐 제체 내 외부 변형을 측정하였다. 그 결과 댐의 안정성 분석과 전체적인 경향을 파악함에 있어서 strain gauge의 계측 값만으로는 한계가 있으므로 관련 계기의 측정값을 함께 검토해야 할 것으로 사료된다.

  • PDF

매스콘크리트 구조물에서의 시멘트 종류별 수화발열 특성 평가 (Evaluation of Thermal Characteristics in Association with Cement Types in Massive Concrete Structure)

  • 김상철;강석화;김진근
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.3-12
    • /
    • 1999
  • The larger, loftier and more highly strengthened the recent structures become, the greater attention is paid to the problem of thermal crack occurrence associate with hydration heat. As one of methods to solve the problem, a care has been taken to the improvement of construction such as the application of pre-cooling or pipe-cooling, adjustment of concrete block size, concrete placement timing, joint arrangement and so on. But it is expected that a proper selection of cement shall additionally contribute to the control of thermal cracks. In this study, thus, we selected 4 types of cements such as Type V for anti-sulphate, blast furnace cements (slag content of 45% and 65% respectively)and ternary blended low heat cement, and carried out mock-up tests. In every assigned time, temperatures and thermal stresses were measured and calculated from raw data. As a result of measurement, it was found that the magnitude of hydration heat is in order of blast furnace slag cement. Type V and ternary blended low heat cement. Results of thermal stresses were same as the order of temperature. In addition, thermal stresses calculated from the data of strain gauges showed almost similar to those measured from effective stress gauges only when strain values were adjusted properly in accordance with initial time of stress appearance. Theoretical results agreed well with the measured values comparatively, but showed slight differences. It is inferred that these differences shall be reduced if more tests capable of evaluating thermal characteristics of concrete are carried out.

팽창 콘크리트를 충전한 강관충전 콘크리트의 물성에 관한 연구 (A Study on Properties of CFT filled with Expansion Concrete)

  • 박춘영;이진성;송종목;김효열;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.117-120
    • /
    • 2008
  • The Purpose of this is properties of CFT filled with expansion concrete. CFT(concrete filled steel tube) is the structure that circle shape steel column filled with concrete. 3 kinds of expansive additives and variation of replacement rate. we changed expansive additive from 0%, 10%, 20%, 30% of ratio of addition rate are selected for this experiment. Merits of CFT are concrete internal force rising influenced by steel shape restriction, reinforcing the local buckling, excellent resistance to transformation. Generally, High rise building using CFT utilize the high strength and fluidity concrete for packing the tube inside. As the result a steel tube charged expensive concrete has stiffness 1.5times more than a steel tube not charged concrete. Increase of resisting power about compressive stress by binding expansion of expansive concrete affects strength increase and softness.

  • PDF

철근구속을 받는 고강도 콘크리트의 자기수축응력에 관한 실험 연구 (An experimental study on the measurement of stress due to autogenous shrinkage of high strength concrete with bar restraint)

  • 최진영;박신일;전철송;임병호;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.67-72
    • /
    • 2002
  • The purpose of this study is to investigate on the measurement of stress due to autogenous shrinkage of high strength concrete according to the W/C ratio at early age. The main parameters are as follows W/C ratio is 25, 30, 40%. The size of specimen is 10$\times$10$\times$150cm and the autogenous shrinkage strain is measured by the bonded strain gauge at the inside of the specimens. From the test, it is suggested that the autogenous shrinkage stress increased as W/C ratio decreased.

  • PDF

유한요소법을 이용한 매스콘크리트구조물의 수화열 및 온도응력 해석에 관한 연구 (A Study on the Heat Transfer Analysis and Thermal Stress Analysis of Mass Concrete Structure by Finite Element Method)

  • 강석화;이용호;정한중;박칠림
    • 콘크리트학회지
    • /
    • 제7권3호
    • /
    • pp.137-148
    • /
    • 1995
  • 본 연구에서는 매스콘크리트의 온도응력을 해석적으로 검토하기 위하여 수화열 및 온도등력 해석용 프로그램을 개발하여 실구조물에 설치한 게이지에 의해 측정한 실측치와 비교검토를 하였다. 또한, 개발한 프로그램의 해석결과와 범용프로그램인 ADINA-T 및ADINA와 해석결과를 비교하였다. 그 결과, 본 연구에서 개발한 해석시스템의 해석결과는 범용프로그램의 해석결과와도 좋은 일치를 보였고, 내부구속이 강한구조물이나 외부구속이 강한 구조물 모두 내부의 온도 및 온도응력분포를 잘 평가하고 있음을 알았다. 따라서 본 연구에서 개발한 수화열 및 온도응력해석 프로그램은 매스콘크리트의 온도응력을 평가하는 데에 충분히 사용할 수 있음이 입증되었다.

광섬유 격자 센서를 이용한 모르타르시편의 온도구배 및 열 변형 측정 (Measurements of Thermal Gradient and Thermal Strain of Mortar Specimens Using Fiber Bragg Grating Sensor)

  • 임홍철;이은주;전흥재;박동녘
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.133-138
    • /
    • 2003
  • FBG sensor의 다중 측정성을 이용하여 모르타르 시편의 열 변형률과 온도 변화를 동시에 측정하였다. 또한, 광섬유 격자 센서를 이용하여, 열 변화에 따른 모르타르 시편의 내부 온도 구배를 측정하였다. 열 변형률을 기존 strain gauge와 함께 측정하였을 때, strain gauge는 섭씨 60도 이상의 온도에서 오차를 보이는 반면, FBG 센서는 안정된 측정값을 나타냈다. FBG 온도 sensor로 측정한 온도 변화량은 thermocouple로 측정한 값과 비교하였으며, 선형적인 대응관계를 보였다.

철도교량에 거동발생 시 응력분포 분석에 따른 적정 방수재료 선정을 위한 평가 방법 (Waterproofing Material Evaluation Method based on Stress Dispersion Analysis due to Displacement in Railway Bridges)

  • 오규환;안기원;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2021
  • To measure the effect of the stress-strain dispersion across the installed waterproofing layer on the concrete surface, a strain gauge was attached to the gap between the waterproofing layer and the concrete structure at specified points of upper, center and bottom of the load-displacement simulation specimen, and the peak stress-strain at the displacement interface were measured and compared with stress-strain at other areas to analyze each material types' stress-strain dispersion ratio properties. Based on the results of the testing, it was shown that materials with high load-displacement resistance performance accordingly had high stress-strain dispersion ratio results, and the materials from highest performance to lowest performance were; CAS, SAS, PUC and CSC.

  • PDF