• Title/Summary/Keyword: concrete road

Search Result 999, Processing Time 0.038 seconds

Evaluation of Endurance for Roadway Sealant (도로용 줄눈재의 내구성 평가)

  • Lee, Hyoung-Wook;Kim, Seung-Jin
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.133-139
    • /
    • 2009
  • Joints on concrete road prevent failure and crack securing the moderate space when concrete slab expands and contracts as a function of varying temperature throughout all seasons. Filling joint sealants in joints can prevent the interruption of slab movement and failure due to the infiltration of alien substances, and also can prevent crack caused by freezing and thawing and Dowel bar corrosion resulted from water - rainfall and snowfall infiltration through the inside the pavement. They lead to the improvement of the commonality of road. This paper evaluates physical strength, weatherability and deicer resistance of a two-year aged sample from joint on concrete road and its virgin sample. It was found that there are significant differences in aspects of weatherability and adhesive force between the tested sample and silicon materials.

  • PDF

Time-Temperature Curve of road tunnel for fire (도로터널 내 화재에 따른 시간-온도 가열곡선 도출)

  • Choi, Min-Jung;Jang, Chang-Il;Lee, Sang-Woo;Kim, Joon-Mo;Won, Jong-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.713-716
    • /
    • 2008
  • This study is performed to propose a standard to evaluate fire protection assessment for concrete structures during a fire on road tunnel. Recently, a number of road tunnels have been rapidly increased and fire risk also multiplyed according to extend tunnel length, due to natural features and environmentally-friendly road construction in domestic. But we have not yet been prescribed appropriate time-temperature curve for tunnel fire. Therefore we presented fire design model and investigated time-temperature curve proposed by a foreign country considering traffic, a kinds of vehicles which are a basis of heat rate.

  • PDF

Construction Method and Control System of the Heat of Hydration for Inchon International Airport Elevated Road Way (인천국제공항 여객터미널 전면 고가 교량 공사 시공방법 및 수화열 대책)

  • 임채만;박명웅;조용기;조선규;김은겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.869-881
    • /
    • 1999
  • Inchon International Airport Elevated Road Way is located between the Passenger Terminal Building and Transportaion Center which are Inchon International Airport core construction projects. The deck of the bridge is consists of 5-span or 6-span continuous pre-stressed concrete slab. Steel form has been used to enhance the quality of texture on concrete slab. Steel form has been used to enhance the quality of texture on concrete surface, lower surface of deck slab with the two way arch has been manufactured by highly professional manner in order to get an beautiful exterior architectural looks. The prestressed concrete deck slab is mass concrete structures with a high-specified concrete strength and a varying section in the range of 0.95-2.8m thickness. Therefore high risks of thermal cracking occurrence by heat of hydration highly are expected. To resolve such problem, we adopted type 1 cement and pipe cooking method at construction site through mass concrete specimen test and 3-dimensional analysis. For Pipe cooling we used 25mm diameter stainless pipes with wrinkles. Cooling pipe with spacing 50-60cm has been installed. And continuous pipe cooling with cooling water of 15$^{\circ}C$ was conducted for 2days. In present 8 span of all 29 spans construction has been completed. No thermal cracking heat hydration has been observed yet.

  • PDF

Electrical signal characteristics of conductive asphalt concrete in the process of fatigue cracking

  • Yang, Qun;Li, Xu;Wang, Ping;Zhang, Hong-Wei
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.469-477
    • /
    • 2014
  • As a kind of intelligent materials, conductive asphalt concrete has a broad application prospect including melting ice and snow on the pavement, closing cracks in asphalt concrete, sensing pavement damage, and so on. Conductive pavement will be suffered from fatigue failure as conventional pavement in the process of service, and this fatigue damage of internal structure can be induced by electrical signal output. The characteristics of electrical signal variation of conductive asphalt concrete in the process of fatigue cracking were researched in this paper. The whole process was clearly divided into three stages according to resistance changes, and the development of fatigue damage wasn't obvious in stage I and stage II, while in stage III, the synchronicity between the resistance and damage began to appear. Thus, fatigue damage variable D and initial damage value $D_0$ represented by the functions of resistance were introduced in stage III. After calculating the initial damage value $D_0$ under different stress levels, it was concluded that the initial damage value $D_0$ had no noticeable change, just ranged between 0.24 and 0.25. This value represented a critical point which could be used to inform the repair time of early fatigue damage in the conductive asphalt pavement.

Change in the Concrete Strength of Forest Road Drainage Systems Caused by Forest Fires (산불로 인한 임도 배수시설의 콘크리트 강도 변화)

  • Ye Jun Choe;Jin-Seong Hwang;Young-In Hwang;Hyeon-Jun Jeon;Hyeong-Keun Kweon;Joon-Woo Lee
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.4
    • /
    • pp.451-458
    • /
    • 2023
  • As forest fires continue to increase in scale worldwide, the importance of forest roads in relation to forest fire prevention and suppression has become increasingly evident. To ensure effective functioning during a forest fire disaster, it is crucial to apply appropriate road planning and ensure roads' structural integrity. However, previous studies have predominantly focused on the impact of forest fires on firebreak efficacy and road placement, meaning that insufficient attention has been paid to ensuring the safety of these facilities. Therefore, this study sought to compare the strength of concrete facilities within areas damaged by forest fires over the past three years by using the rebound hammer test to identify signs of thermal degradation. The results revealed that concrete facilities damaged by forest fires exhibited significantly lower strength (15.6 MPa) when compared with undamaged facilities (18.0 MPa) (p<0.001), and this trend was consistent across all the target facilities. Consequently, it is recommended that safety assessment criteria for concrete forest road facilities be established to prevent secondary disasters following forest fire damage. Moreover, continuous monitoring and research involving indoor experiments are imperative in terms of enhancing the stability of forest road structures. It is expected that such research will lead to the development of more effective strategies for forest fire prevention and suppression.

Skid Resistance Characteristics of Pavement Surface (포장노면 미끄럼 저항특성)

  • Kim, Yong-Seok;Hong, Jae-Cheong;You, Hyeong-Mok
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • PURPOSES : Skid resistance on pavements plays an important role in reducing the risk of vehicle skidding on wet surface particularly. Almost 9.3 percent of traffic accidents were occurred under rainy condition and these are over-represented in terms of the severity of the crashes. Recently, unusual weather conditions referred widely as the intensified rainfalls justify the need of a systematic management of skid resistance. In this context, the study carried out the observational study on the skid resistance characteristics of different types of pavement with the time passage. METHODS : This study measured the skid resistance with Pavement Friction Tester at three times within five years. The skid resistance measurement has followed the method suggested by ASTM. RESULTS : As the main results under the scope of this study, skid resistance of asphalt concrete has not nearly reduced with time. On the contrary, skid resistance of cement concrete has been rapidly reduced with time though the highest resistance was gained at the early observation. Porous asphalt concrete shows a steady decrease of skid resistance with time, anyway, the reduction rate according to the increase of measurement speeds is relatively lower than the others. CONCLUSIONS : Based on our study, skid resistance of the pavement should be regarded as one of the pavement management system, so periodic measurement should be made to assure road safety as a whole.

A study of deterioration of reinforced concrete beams under various forms of simulated acid rain attack in the laboratory

  • Fan, Yingfang;Hu, Zhiqiang;Luan, Haiyang;Wang, Dawei;Chen, An
    • Structural Engineering and Mechanics
    • /
    • v.52 no.1
    • /
    • pp.35-49
    • /
    • 2014
  • This paper studies the behaviour of deteriorated reinforced concrete (RC) beams attacked by various forms of simulated acid rain. An artificial rainfall simulator was firstly designed and evaluated. Eleven RC beams ($120mm{\times}200mm{\times}1800mm$) were then constructed in the laboratory. Among them, one was acting as a reference beam and the others were subjected to three accelerated corrosion methods, including immersion, wetting-drying, and artificial rainfall methods, to simulate the attack of real acid rain. Acid solutions with pH levels of 1.5 and 2.5 were considered. Next, ultrasonic, scanning electron microscopy (SEM), dynamic, and three-point bending tests were performed to investigate the mechanical properties of concrete and flexural behaviour of the RC beams. It can be concluded that the designed artificial simulator can be effectively used to simulate the real acid rainfall. Both the immersion and wetting-drying methods magnify the effects of the real acid rainfall on the RC beams.