• Title/Summary/Keyword: concrete cover depth

Search Result 144, Processing Time 0.027 seconds

Evaluation of Minimum Depth Criterion and Reinforcement Effect of the Soil Cover in a Long-span Soil-steel Bridge (장지간 지중강판구조물의 최소토피고 평가 및 토피지반 보강에 대한 수치해석)

  • 이종구;조성민;정현식;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.67-78
    • /
    • 2004
  • Soil-steel bridges are made of flexible corrugated steel plates buried in the well-compacted granular soil. One kind of possible collapses of these structures could be initiated by shear or tension failure in the soil cover subjected to vehicle loads. Current design codes provide the requirements for the minimum depth of the soil cover to avoid problems associated with soil cover failures. However, these requirements were developed for short span (less than 7.7 m) structures which are made of unstiffened plates of standard corrugation (150$\times$50 m). Numerical analyses were carried out to investigate the behavior of long span soil steel bridges according to thickness of the soil cover. The span of structures were up to 20 m and deep corrugated plates (381$\times$140 m) were used. The analysis showed that the minimum cover depth of 1.5 m could be sufficient to prevent the soil cover failure in the structures with a span exceeding 10 m. Additional analyses were performed to verify the reinforcement effect of the concrete relieving slab which can be a special feature to reduce the live-load effects. Analyses revealed that the bending moment of the conduit wall with a relieving slab was less than 20% of that without a relieving slab in a case of shallow soil cover conditions.

Research of Steel Corrosion and Corrosion Protection System for Reinforcing Steels in Concrete Exposed to Chloride Environments. (염해환경하 철근콘크리트의 철근 부식 및 방식기법 연구)

  • 문홍식;이상국;송호진;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.653-658
    • /
    • 2001
  • Recent long-span bridges, such as Kwang-Ahn Grand bridge, Seo-Hae Grand Bridge, Young-Jong Grand Bridge, etc, have been designed and constructed near the shore. Thus, it needs to analyze the durability of marine concrete structures which are exposed to severe chloride environments. It is well known that corrosion of reinforcement steel in concrete is one of the major factors for the durability of concrete structures. The objective of this experimental study is to investigate the performance of impressed current system and corrosion inhibitors for the corrosion protection of reinforced concrete structures. Concrete test specimens were made with various test parameters, such as cover depth, steel diameter, compressive strength, direction and frequency of notch. For the efficient evaluation of these corrosion protection systems, these tests have been carried out in the shore.

  • PDF

Development of Durability Design System for Concrete Structures (콘크리트 구조물의 내구성 설계시스템 개발)

  • 변근주;권성준;송하원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.161-166
    • /
    • 1998
  • The concrete structures designed and constructed by conventional design concept based on structural performance consideration show sometimes serious durability problem when the structures are exposed to aggressive environment. Because present design system focuses on the structure safety and considers durability indirectly by the concrete mix design and cover depth, the durability of concrete structure cannot be ensured. As the first step to develope the durability design for concrete structure, durability index which represents internal concrete resistance and environment index which represents external environmental exposure are derived quantitatively. In the next step, the durability design system is developed by checking durability limit state with computed two indexes under service life condition by considering of the reliability of structure. Finally, the proposed system is verified with a model problem.

  • PDF

An experimental study on the evaluation of chloride attack resistance in mortar and concrete mixed with pozzolanic admixtures (포졸란계 혼화재를 혼입한 모르타르 및 콘크리트의 내염해 저항성 평가에 관한 실험적 연구)

  • 박정준;김도겸;하진규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.461-466
    • /
    • 2000
  • To improve the quality of concrete, we usually consider the reduction of water/cement ratio, the increase of concrete cover depth and the use of mineral admixtures. Reportedly, the use of admixtures make concrete more durable and tighten against water. But, it is needed to study more about the relationship between the admixtures and the chloride ion diffusion. Therefore, in this study, we focused on the chloride ion diffusion properties of the pozzolanic admixtures such as fly-ash, slag and silica fume which are known as being useful on chloride attack resistance when mixed into mortar or concrete. Furthermore, we treed to analyze the correlation between mortar and concrete using the admixture, which is useful for analyzing chloride ion diffusion mechanism.

  • PDF

Corrosion Behavior and Ultrasonic Velocity in RC Beams with Various Cover Depth (다양한 피복두께를 가진 RC 보의 부식 거동 및 초음파 속도)

  • Jin-Won Nam;Hyun-Min Yang;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.184-191
    • /
    • 2023
  • With increasing corrosion in RC (Reinforced Concrete) structures, cracks occurred due to corrosion products and bearing load resistance decreased. In this study, corrosion was induced through an accelerated corrosion test (ICM: Impressed Current Method) with 140 hours of duration, and changes in USV (Ultra-Sonic Velocity), flexural failure load, and corrosion weight were evaluated before and after corrosion test. Three levels of cover depth (20 mm, 30 mm, and 40 mm) were considered, and the initial cracking period increased and the rust around steel decreased with increasing cover depth. In addition, the USV linearly decreased with decreasing cover depth and increasing amount of corrosion. In the flexural loading test, the bending capacity decreased by more than 10% due to corrosion, but a clear correlation could not be obtained since the corrosion ratio was small, so that the effect of slip was greater than that of reduced cross-sectional area of steel due to corrosion. As cover depth increased, the produced corrosion amount and USV changed with a clear linear relationship, and the cracking period due to corrosion could be estimated by the gradient of the measured corrosion current.

Detection of Voids inside Concrete Using Radar (레이더를 이용한 콘크리트내 공동 탐사)

  • 임홍철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.817-820
    • /
    • 2000
  • Existence of void or delamination inside building foundation or tunneling lining can cause serious problems in structural safety. Therefore, 0probing of such voids in architectural and civil structures is an important process in evaluating the overall integrity of the structures. In this study, the radar method has been examined in its use in detecting voids inside concrete specimens. The dimensions of the specimens are 1,000 mm(width) $\times$ 600 mm (height) $\times$ 140 mm (thickness). A void is embedded inside concrete specimens with the dimensions of 200 mm(width) $\times$ 600 mm (height) $\times$ 50 mm (thickness). Concrete cover depth of 30 mm, 60 mm is studied for comparison. In both cases, the voids is located with 1 GHz antenna.

  • PDF

Prediction of Time to Corrosion for Concrete Bridge Decks Exposed to De-Icing Chemicals (제빙화학제 살포로 인한 콘크리트 교량 바닥판의 철근부식 시작시기의 예측)

  • Lee, Chang-Soo;Yoon, In-Seok;Park, Jong-Hyok
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.606-614
    • /
    • 2003
  • The major cause of deterioration for the concrete bridge decks exposed to de-icing chemicals would be chloride-induced reinforcement corrosion. Thus, in this paper, in order to predict time to corrosion for concrete bridge decks in the urban area, chloride concentration was measured with depth from the surface. A frequency analysis on surface chloride concentration and chloride diffusion coefficient of concrete bridge deck equals 0.192, 29.828 in the scale parameter and 7.899, 1.983 in the shape parameter of gamma distribution. The average value of surface chloride concentration equals 1.5 kg/㎥ and condenses from 1 to 2 kg/㎥ in the level of probability 70%. From the probabilistic results, it is confirmed that 26mm of minimum cover depth in order to target 20 years over is calculated. The countermeasure strategy to extend the service life of concrete bridge deck exposed to de-icing chemicals would be an effective method to increase cover depth and to place high performance concrete, which could lead to reduce the chloride diffusion coefficient and distribution range.

On the Implementation of Fuzzy Arithmetic for Prediction Model Equation of Corrosion Initiation

  • Do Jeong-Yun;Song Hun;Soh Yang-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1045-1051
    • /
    • 2005
  • For critical structures and application, where a given reliability must be met, it is necessary to account for uncertainties and variability in material properties, structural parameters affecting the corrosion process, in addition to the statistical and decision uncertainties. This paper presents an approach to the fuzzy arithmetic based modeling of the chloride-induced corrosion of reinforcement in concrete structures that takes into account the uncertainties in the physical models of chloride penetration into concrete and corrosion of steel reinforcement, as well as the uncertainties in the governing parameters, including concrete diffusivity, concrete cover depth, surface chloride concentration and critical chloride level for corrosion initiation. The parameters of the models are regarded as fuzzy numbers with proper membership function adapted to statistical data of the governing parameters and the fuzziness of the corrosion time is determined by the fuzzy arithmetic of interval arithmetic and extension principle

Estimation of Carbonation and Service Life of Box Culvert for Power Transmission Line (박스형 전력구의 콘크리트 탄산화에 의한 잔존수명 예측)

  • Woo, Sang Kyun;Lee, Yun;Yi, Seong Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.116-121
    • /
    • 2012
  • The construction of underground structures such as box culverts for electric power transmission is increasing more and more, and the life extension of these structures is very important. Carbonation-induced corrosion in concrete may often occur in a high carbon dioxide environment. In this study, the risk of carbonation of two concrete box culverts in an urban area was evaluated by measuring the carbonation rate and concrete cover depth. Then, the carbonation-free service life at the depth of the steel was calculated, based on in situ information, by the Monte Carlo simulation. The service life of box culvert due to carbonation was estimated over 250 years via Monte Carlo simulation.

A Study on the Corrosion Properties of Reinforcing bar and Performance Evaluation of Repair Material and Method for Reinforced Concrete Structure by Exposure Experiment under the Coastal and Normal Atmosphere Environment (해양 및 일반대기환경의 폭로실험에 의한 철근콘크리트구조물 보수재료.공법의 성능평가 및 철근의 부식특성에 관한 연구)

  • Nam Jeong-Soo;Roh Kyung-Min;Shin Seung-Bong;Kim Young-Sun;kim Gyu-Yong;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.167-171
    • /
    • 2006
  • In this study, for the establishment of the performance evaluation methods of repair material and method for reinforced concrete structure and the quality control standards of durability recovery method, the quantitative exposure data by exposure experiment under the coastal and normal atmosphere environment is accumulated and analyzed. Investigating and evaluating the result of exposure experiment during 30 months of exposure age under the coastal and normal atmosphere environment, carbonation depth and chlorideion penetration depth very little penetrated than cover depth. It seems reasonable to conclude that main cause of corrosion of reinforcing bar are inner chloride-ion and macro cell from the result of corrosion area and corrosion velocity. Accordingly, it is considered that fundamental data on the performance evaluation and quality control standards of repair material and method could be presented through continuous exposure test in the future.

  • PDF