• 제목/요약/키워드: concentration point

Search Result 1,867, Processing Time 0.03 seconds

An Examination of Sediment Discharge Computation Errors Related to Imprecise Factors (부정확한 인자와 관계된 유사량 산정 오류에 대한 검증)

  • 정관수
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.129-142
    • /
    • 1996
  • This study investigates the magnitude of errors that can be expected in integrating sediment concentration in a vertical, basede on a single-point measurement, because of errors in input data. Potential error sources, including sampler location, water surface elevation, bed elevation, fall velocity, $\beta$ value, and $\kappa$ value were comparatively examined using data from a special study on the Rio Grande Conveyance channel in New Mexico. It is concluded that simple forms of equations for the vertical distribution of velocity and sediment concentration based on a single-point field sample of suspended sediment. The most uncertain point in the computation is related to the Rouse number z in the equation for the vertical concentration distribution of suspended sediment.

  • PDF

Effect of Light Intensity, Temperature and $CO_2$ Concentration on Photosynthesis in Hovenia dulcis Thunb. (광도, 온도 및 $CO_2$의 농도가 헛개나무의 광합성에 미치는 영향)

  • Lee, Kang-Soo;Choi, Sun-Young
    • Korean Journal of Medicinal Crop Science
    • /
    • v.10 no.1
    • /
    • pp.1-4
    • /
    • 2002
  • This study was carried out to know the effect of light intensity, temperature and $CO_2$ concentration on photosynthesis and transpiration in Hovenia dulcis Thunb. Light compensation point was $2.4\;{\mu}mol\;m^{-2}\;s^{-1}$ and light saturation point was $1033\;{\mu}mol\;m^{-2}\;s^{-1}$. The optimum temperature for photosynthesis was $25^{\circ}C$ at $1000\;{\mu}mol\;m^{-2}\;s^{-1}$ light intensity. $CO_2$ compensation point was 67 vpm and $CO_2$ saturation point was 707 vpm. Transpiration rate was increased to about $2\;mmol\;m^{-2}\;s^{-1}$ with increasing of light intensity to $1750\;{\mu}mol\;m^{-2}\;s^{-1}$ and to above $4\;mmol\;m^{-2}\;s^{-1}$ with increasing of temperature from $18^{\circ}C$ to $36^{\circ}C$. however It was gradually reduced as $CO_2$ concentration increased from 21 vpm to 800 vpm.

Determination of Urinary Cotinine Cut-Off Point for Discriminating Smokers and Non-Smokers among Adolescents: The Third Cycle of the Korean National Environmental Health Survey (2015~2017) (청소년의 흡연자 선별을 위한 소변 중 코티닌 절사점 결정: 제3기 국민환경보건 기초조사(2015~2017))

  • Jung, Sunkyoung;Park, Sangshin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.320-329
    • /
    • 2021
  • Background: Smoking exposure may be objectively assessed through specific biomarkers. The most common biomarker for smoking is cotinine concentration in urine, and setting an optimal cut-off point can accurately classify smoking status. Such a cut-off point for Korean adolescents has never been studied. Objectives: The aim of this study was to determine a cut-off point for urinary cotinine concentration for the discrimination of smoking in adolescents. Methods: Participants were adolescents aged 13~18 years who participated in the third cycle of the Korean National Environmental Health Survey. We used urine samples to confirm the level of cotinine concentrations. Smoking status was determined by self-reported questionnaire. We identified the optimal cotinine cut-off point for discriminating smoking status using receiver operating characteristic curve analysis. Results: Of the 904 participants, 28 (3.1%) were smokers, among whom 20 (71.4%) were male. The median urinary cotinine concentrations in smokers was 218 ㎍/L (male: 215 ㎍/L, female: 303 ㎍/L), and that in non-smokers was 1.31 ㎍/L (male: 1.46 ㎍/L, female: 1.18 ㎍/L). We found significant differences in urinary cotinine concentration according to smoking status and sex (p<0.001). Urinary cotinine concentrations performed well for identifying smoking adolescents [area under the curve: 0.954 (male: 0.963, female: 0.908)]. The cut-off that optimally distinguished smokers from non-smokers was 39.85 ㎍/L (sensitivity: 89.3%, specificity: 97.4%). Male [39.85 ㎍/L (sensitivity: 90.0%, specificity: 94.9%)] had a different optimal cut-off point than female [26.26 ㎍/L (sensitivity: 87.5%, specificity: 99.6%)]. Conclusions: This study determined a cut-off point for urinary cotinine of 39.85 ㎍/L (male: 39.85 ㎍/L, female: 26.26 ㎍/L) to distinguish smokers from non-smokers in adolescents.

Analysis for Removal Efficiency of Non-point Pollution Sources by Constructed Wetlands (인공습지 형태에 따른 비점오염저감효율 분석)

  • Lee, Sang Hyuk;Kim, Lee Hyung;Cho, Hye Jin
    • Ecology and Resilient Infrastructure
    • /
    • v.1 no.2
    • /
    • pp.102-108
    • /
    • 2014
  • Studies of non-point pollutant treatment facilities have widely been conducted for a decade, but natural non-point pollutant treatment facilities implemented on roads have not been carried out for the removal efficiency of non-point pollution sources. This study analyzed the removal efficiency of non-point pollution sources from constructed wetlands using monitoring and event mean concentration method. As a result of this study, removal efficiency of general non-point pollution sources as TSS, COD, BOD is relatively good, but removal efficiency of TN, TP, Cr, Zn, Pb is very small or nothing.

A Mathematical Framework for Estimating Non-point Waste Load at Enclosed Beaches (연안 하구역 내의 비점오염부하량 산정을 위한 수학모델의 적용)

  • Ahn, Jong Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.111-115
    • /
    • 2010
  • Beaches in estuaries, bays, and harbors are frequently contaminated with indicators of human pathogens such as fecal indicator bacteria. Tracking down the sources of contamination at these enclosed beaches is complicated by the many point and non-point sources that could potentially degrade water quality along the shore. A mathematical framework was developed to test quantitative relationships between fecal indicator bacteria concentration in ankle depth water at enclosed beaches, the loading rate of fecal indicator bacteria from non-point sources located along the shore, physical characteristics of the beach that affect the transport of fecal indicator bacteria across the beach boundary layer, and a background concentration of fecal indicator bacteria attributable to point sources of fecal pollution that impact water quality over a large region of the embayment. Field measurements of fecal indicator bacteria concentrations and water turbulence at an enclosed beach were generally consistent with predictions and assumptions of the mathematical model, and demonstrated its utility for assessing waste load of non-point sources, such as runoff, bather shedding, bird droppings, and tidal washing of contaminated sediments.

A Theoretical study of Oxidation-Reduction Titration Curves (산화${\cdot}$환원 적정곡선의 이론적 고찰)

  • Choe, Gyu-Won
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.4
    • /
    • pp.287-296
    • /
    • 1970
  • The varation of potential and completeness of reaction in an oxidation-reduction titration of Red$_1$ ($a\;Ox_1+N_1e{\leftrightarrow}b\;Red_1)\;by\;Ox_2\;(C\;Ox_2+n_2e{\leftrightarrow}d\;Red_2)$ is analyzed on the basis of general expressions. It is shown that the reaction deficiency as well as the rate of variation of the potential with titration fraction change in proportion to the $[n_2(a-b)-n_1(c-d)]$ th power of the concentration of the reagents. In particular, at the equivalence point, the expression of the potential contains a concentration dependent term that is proportional to ac-bd. Thus, the equivalence-point potential varies with the concentration of the reagents unless ac=bd is satisfied. It is also shown that the sharpness of the potentiometric titration curve is shown to occur either prior to or after the equivalence point depending upon whether $n_1cn_2b$, the deviation being the same order of magnitude as the relative deficiency at the equivalence point.

  • PDF

A Study on the Measurement of SOx-Dew Point (About the Corosin of Briquet -Burning Hot Water Boiler) ($SO_x^-$ 노점 측정에 관한 연구 (연탄 온수보일러의 부식문제에 관하여))

  • Chae Jae-Ou;Yong Gee-Joong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.4
    • /
    • pp.252-263
    • /
    • 1983
  • In the briquet-burning hot water boiler the $SO_x$-dew point is calculated and found to be between $130^{\circ}C\;and\;154^{\circ}C$. The corrosion rate depends on the surface temperature and the concentration of the condensate on the surface. The concentration of the condensate is decided acoording to the difference detween $SO_x$-dew point and the surface temperature. When the surface temperature is $80^[\circ}C$, the concentration of the condensate is also high (0.15N). Therefore the high concentration and high temperature promote the high corrosion rate of $14{\times}13^{-3}g/100cm^2{\cdot}hr$ on the SS41 material. On the other hand, when the surface temperatures are $60^{\circ}C\;and\;40^{\circ}C$, the concentrations and the co..sion rates are reduced dramatically to $0.11\;N,\;8.6{\tiems}10^{-3}g/100cm^2{\cdot}hr$ and $5{\tiems}10^{-4}g/100cm^2{\cdot}hr$ respectively.

  • PDF

On the Critical Behavior of Phase Changes of a Forward-Scattered Light in a Nonpolar Binary Liquid Mixture

  • Kim, Kyoung-Ran;Kang, Young-Soo;Lee, Dong-J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.12
    • /
    • pp.1749-1753
    • /
    • 2002
  • The effect of concentration fluctuations on the changes of azimuth and ellipticity are analytically obtained in a binary chiral liquid mixture, when the incident light is completely linearly polarized above (or below) the horizontal at 45°. The important results are as follows;(1) When the binary liquid is in the critical region far from the cr5itical point, the ellipticity change is proportional to isothermal compressibility factor and the fifth order of frequency and shows the logarithmic divergence. (2) In the case that the system is in the critical region far from the critical point, the azimuth change is solely due to the molecular contribution. As the system approaches to the critical point, the effect of fluctuations becomes important. If it is in the extreme close to the critical point, the term due to the concentration fluctuations is comparable to or larger than the molecular contribution.

A Study on the Development of Thin ESP for High Efficient Air-conditioner (공조용 박형 전기집진장치 개발에 관한 연구)

  • Hong, Yeong-Gi;Sin, Su-Yeon;Jo, Jeong-Su;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.1
    • /
    • pp.34-38
    • /
    • 1999
  • In order to develop a thin type ESP(Electrostatic Precipitator) for high efficient air-conditioner with low concentration of ozone generation, collecting electrode spacing should be narrower than that from Deutsch formula and minimizes discharge current in ionizer. In this paper, the effect of applied voltage on the precipitation efficiency and ozone concentration of scroll type ESP was studied. As a result, precipitation efficiency(one pass) was improved by about 30[%] from increment of collector voltage(3.5[㎸]). Precipitation efficiency was increased with increasing ionizer voltage. And after some point, the efficiency was saturated. At the point, voltage and ionizer current was 5.2[㎸] and 95$[\muA]$ per meter respectively. At these applied voltage conditions, ozone concentration was saturated about 0.01[ppm] after 3 hours in 23$[m^3]$ closed room test.

  • PDF

Effect of the Nano Ceria Slurry Characteristics on end Point Detection Technology for STI CMP (STI CMP용 가공종점 검출기술에서 나노 세리아 슬러리 특성이 미치는 영향)

  • 김성준;강현구;김민석;백운규;박재근
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.1
    • /
    • pp.15-20
    • /
    • 2004
  • Through shallow trench isolation (STI) chemical mechanical polishing (CMP) tests, we investigated the dependence of pad surface temperature on the abrasive and additive concentrations in ceria slurry under varying pressure using blanket film wafers. The pad surface temperature after CMP increased with the abrasive concentration and decreased with the additive concentration in slurries for the constant down pressure. A possible mechanism is that the additive adsorbed on the film surfaces during polishing decreases the friction coefficient, hence the pad surface temperature gets lower with increasing the additive concentration. This difference in temperature was more remarkable for the higher concentration of abrasives. In addition, in-situ measurement of spindle motor was carried out during oxide and nitride polishing. The averaged motor current for oxide film was higher than that for nitride film, meaning the higher friction coefficient.

  • PDF