Evaluation of Metal Biosorption Efficiency of Laboratory-grown Microcystis under Various Environmental Conditions

  • Pradhan, Subhashree;Singh, Sarita;Rai, Lal Chand;Parker, Dorothy L.
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 1998
  • This study examines the effect of pH, temperature, metal ion concentration and culture density on metal biosorption by the nuisance cyanobacterium Microcystis aeruginosa. Ni biosorption was higher at pH 9.2 than at neutral and acidic pH. In contrast the biosorption of Cu and Zn was maximum at pH 7.0. However, biosorption of Zn was difficult to measure at pH values 9.2 and 10.5, owing to the formation of insoluble complexes. All the test metals (Cu, Zn, and Ni) showed maximum biosorption rate at low culture densities of 40 mg dry wt $1^{-1}$. The biosorption of Cu, Zn, and Ni was maximum at $40^{\circ}C$. However, no worthwhile difference in Zn and Ni sorption was noticed at 4 and $29^{\circ}C$ as compared to $40^{\circ}C$. Of these three metals used Microcystis showed a greater binding capacity ($K_{f}$ value=0.84, Freundlich adsorbent capacity) and accelerated biosorption rate for Cu under various environmental conditions. Fitness of mathematical models on metal biosorption by Microcystis confirmed that the biological materials behave in the same way as physical materials. These results suggest that before using a biosorbent for metal recovery, the environmental requirements of the biosorbent must be ascertained.

  • PDF

Preparation and Characteristics of $CdS_{1-x}Te_{1-x}$ Ternary Polycrystalline Thin Films by Co-evaporation (동시 열증착법에 의한 $CdS_{1-x}Te_{1-x}$ 삼원계 다결정 박막의 제작과 특성)

  • 박민서;송복식;정성훈;문동찬;김선태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.126-130
    • /
    • 1995
  • $CdS_{1-x}Te_{1-x}$ polycrystalline thin films were fabricated from CdS and CdTe powder by co-evaporation method at $10^{-6}$ Torr. The Optimum evaporation condition was substrate temperature $T_{s}$=$150^{\circ}C$, evaporation time t=30 min. XRD spectrums indicated that the crystal structure chanced from zinc blonde (x$\leq$0.22) to wurtzite (x$\geq$0.96) through mixed structure (0.22$\leq$0.74) as composition value x increase to CdS. Conductive type was n-type by hot point probe method. van der Pauw method was not applicable for x<0,5 due to high hall voltages, Electrical resistivity and Hall carrier mobility were decreased as x increase, while Hall carrier concentration was increased. The optical bandgap of $CdS_{1-x}Te_{1-x}$ polycrystalline thin films measure d at R.T. had quardratic form and the bowing parameter was fitted as 1.98eV for theoretical value of 2.0eV. I-V characteristics of In/CdTe/$CdS_{x}Te_{1-x}$Au Schottky diodes showed that CdS-rich one had better forward characteristics than CdTe-rich one.

  • PDF

A Modified Back-Titration Method to Measure Soil Titration Curves Minimizing Exchange Acidity and Dilution Effects (토양 적정곡선 측정을 위하여 교환산도와 희석효과를 최소화한 수정역적정법 제안)

  • Jozefaciuk, G.;Shin, Jae Sung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.4
    • /
    • pp.321-327
    • /
    • 1996
  • A back titration method was suggested to determine the exchangeable acidity of soil originated from exchangeable aluminum and adsorbed hydrogen ion in relation to minimizing its titration error. In this method. soils are treated by neutral salt solution whose concentration is the same as soil solution suspended by distilled water. And then. its pH is adjusted at 3, using 1 N HCl solution and back-titrated by 0.1 N NaOH solution containing 1 N NaCl. The results of the suggested back-titration showed the possibility of practical application with linear relationship to that of standard method.

  • PDF

Simultaneous NO2 and RSP Measurements Using Filtration Method (필터방식을 이용한 이산화질소 및 호흡성 분진의 동시 측정)

  • Yang, Won-Ho;Im, Sung-Kuk;Kim, Moon-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.148-152
    • /
    • 2008
  • Coated filters were developed to replace the glass impinger methods that use reagent solutions. The purpose of this study was to simultaneously measure nitrogen dioxide ($NO_2$) and respirable suspended particles (RSP) by a filtration method with a cyclone connected to a pump. A first pre-filter for RSP and second filter for $NO_2$, which was soaked in a TEA (Triethanolamine) solution, were loaded into a filter cassette with a pump flow rate of 1.7 l/m. After sampling, the TEA soaked filter was removed from the cassette, placed in a large test tube (10 ml), mixed, and allowed time to develop. The absorbance (abs) of the diazo compound of the $NO_2$ and N-(1-Napthylethylenediamine dihydrochloride) in the color reagent was measured at 545 nm on a spectrophotometer. The collection efficiency(%) of $NO_2$ by each 3 filter soaked in TEA solution and used in the cyclone with a pump flow rate 1.7 l/m was $89{\pm}3%$ and the correlation coefficient between the true $NO_2$ concentration and that determined by the TEA soaked filters was 0.993(p<0.001).

A Study on the Characteristics of Indoor Air Quality in Elevator (엘리베이터 실내공기질의 특성 기초조사)

  • Park, Jeong-Ho;Choo, Yeon-Gyu;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.677-685
    • /
    • 2012
  • The elevator is needed healthy and comfortable indoor air quality (IAQ) for using many people, but we found nothing about IAQ studies of an elevator. In general, air in the elevator car is sucked from the elevator's hoistway straight into the car using a fan. The air sucked into the hoistway may be filled with dust, mold and bacteria. This study was performed to measure of characteristics of indoor air quality (PM10, falling bacteria, $CO_2$, Rn and HCHO) in elevator's hoistway, CAR and lobby of 8 sites (4 apartments and 4 commercial buildings) in Gyeongnam from May, 2010 to January, 2011. With regards to the differences of pollutant distribution among hoistway, CAR, and lobby, the concentration of Rn and HCHO were the highest in hoistway followed by CAR and lobby, and PM10, falling bacteria and $CO_2$ were the highest in CAR followed by hoistway and lobby. Mean concentrations of PM10 were 104.9 ${\mu}g/m^3$ in CAR, 92.3 ${\mu}g/m^3$ in hoistway and 68.2 ${\mu}g/m^3$ in lobby, respectively.

A Effect of Nutrition Counseling for Improving Iron Status of Female College Students (여대생의 철분영양상태 개선을 위한 영양상담 효과)

  • 홍순명;김은영
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.5
    • /
    • pp.1158-1163
    • /
    • 1999
  • The purpose of this research is to measure nutrition counseling effects for improving iron status. The major components of the nutrition counseling were iron, MPF(Meat, Poultry, Fish) and vitamin C rich diet therapy, the provision of nutrient supplements and eatting attitude education. Fifteen female volun teers participated and the mean level for hemoglobin(Hgb), hematocrit(Hct), serum iron(S Fe), total iron binding capacity(TIBC), serum ferritin(SF) of subjects was 11.9±1.3g/dl, 37.0±2.7%, 57.7 ±33.9 g/dl, 409.1±56.2 g/dl, 8.6±3.5ng/ml, respectively. To evaluate the effect of iron status improvement by the nutrition couseling, 10 subjective symptoms, hematological indice and eating attitude were measured after implementation the nutrition counseling. Some subjective symptoms such as 'cold hands and foot', 'slow to recover', 'reduced concentrate', 'poor memory', 'inflammed inner mouth' were improved significantly. The hemoglobin, hematocrit, mean cell volume(MCV), mean cell hemoglobin(MCH) and mean cell hemo globin concentration(MCHC) were increased significantly. And eating attitude was improved significantly as well. It is suggested from the results that the nutrition counseling of this study can be effective to improve iron status.

  • PDF

Study of Hydraulic Transport of Sand-water Mixture by a Dredging Test Loop (준설시험루프를 이용한 모래-물 혼합물 배송에 관한 연구)

  • Lee, Man-Soo;Park, Young-Ho;Lee, Young-Nam;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1504-1511
    • /
    • 2005
  • The efficiency of the hydraulic transport of soil-water mixtures is an important factor in designing and operating a pump & pipeline system and is directly connected with dredging cost and working period. However, the hydraulic transport mechanism in the slurry flow inside the pipeline such as frictional losses, specific energy consumption, deposition velocity has not been well established. In this study a new dredging test loop system was designed and built. It is composed of a slurry pipeline with pipes of different diameters, a centrifugal slurry pump and a diesel engine connected with the slurry pump. and equipped with modern measuring facilities that enable to measure all important characteristics of a transportation system. The objective of this paper is to discuss the efficiency of the hydraulic transport of the Jumoonjin sand-water mixtures in the dredging test loop and to present simple equations induced from the test results of the loop that can express the transport product and the transport productivity.

  • PDF

Effects of Peripheral Pentacene Region on C-V Characteristics of Metal-Oxide-Pentacene Capacitor Structure

  • Jung, Keum-Dong;Jin, Sung-Hun;Park, Chang-Bum;Shin, Hyung-Cheol;Park, Byung-Gook;Lee, Jong-Duk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1284-1287
    • /
    • 2005
  • Peripheral pentacene region gives a significant influence on C-V characteristics of metal-oxide-pentacene capacitor structure. When the gate voltage goes toward negative, the effect of peripheral pentacene region becomes larger. Remaining gate DC bias constant and changing small signal frequency, the capacitance of peripheral pentacene changes along with frequency so that the total capacitance value also changes. The influence of peripheral pentacene region should be removed to measure accurate C-V characteristics, because it is hard to take into account the effect of the region quantitatively. After removing the influence of peripheral pentacene region, acceptor concentration, flat band voltage and depletion width of pentacene thin film are extracted from an accurate C-V curve as $1.58{\times}10^{17}cm^{-3}$, -1.54 V and 39.4 nm, respectively.

  • PDF

Experimental Analysis of Corbel Part Behaviour in Inground LNG Storage Tank (지하식 저장탱크 Corbel부 실험적 거동 분석)

  • Yoon I.S.;Kim J.K.;Kim Y.K.;Kim J.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.56-60
    • /
    • 2006
  • The connection part (corbel) between bottom slab and side wall in inground LNG storage tank has hinge conditions partly fixed by using anchor bars to reduce stress concentration. The corbel deforms in both radial and vertical directions under load conditions of the LNG tank such as LNG temperature, hydraulic pressure, etc. Membrane is an important part from the viewpoint of design because the deformation of the corbel is transformed directly to the membrane and superposed with other deformations. Behavior of the corbel has been investigated through various sensors to measure temperature, load and displacement. And the test data have been compared with finite element results analysis to propose a more reasonable design of LNG storage tank.

  • PDF

Forced Vibration Testing of Full-scale Non-seismic Reinforced Concrete Frame Structure Retrofitted Using FRP Jacketing System (FRP자켓 시스템이 보강된 비내진 철근콘크리트 골조의 실물 크기 강제 진동 실험)

  • Shin, Jiuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.281-289
    • /
    • 2018
  • Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.