Experimental Analysis of Corbel Part Behaviour in Inground LNG Storage Tank

지하식 저장탱크 Corbel부 실험적 거동 분석

  • Published : 2006.03.01

Abstract

The connection part (corbel) between bottom slab and side wall in inground LNG storage tank has hinge conditions partly fixed by using anchor bars to reduce stress concentration. The corbel deforms in both radial and vertical directions under load conditions of the LNG tank such as LNG temperature, hydraulic pressure, etc. Membrane is an important part from the viewpoint of design because the deformation of the corbel is transformed directly to the membrane and superposed with other deformations. Behavior of the corbel has been investigated through various sensors to measure temperature, load and displacement. And the test data have been compared with finite element results analysis to propose a more reasonable design of LNG storage tank.

지하식 LNG 저장탱크의 Bottom Slab와 Side Wall의 연결부(코벨)는 응력집중을 완화하기 위하여 앵커바를 사용하여 부분적으로 고정되는 힌지 조건을 갖는다. 그러므로 LNG저장탱크 하중 조건인 LNG온도, 지하수압 등에 의해 방사 방향과 수직 방향으로 변형된다. 멤브레인 설계 관점에도 이러한 변형값이 직접 전달되어 중첩되므로 중요한 부분이다. 본 논문에서는 코벨부의 실제 거동을 조사하기 위하여 센서를 설치하여 온도, 하중 그리고 변위를 측정하였다. 또한 FEM 해석으로 예측한 하중조건에 대한 설계 값과 비교하여 합리적인 설계를 제시하고자 하였다.

Keywords