• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.038 seconds

An Experimental Study on Apoptosis of cultivated Wild Ginseng Distilled Herbal Acupuncture by Concentration Level (농도별(濃度別) 산양산삼(山養山蔘) 증류약침(蒸溜藥鐵)의 Apoptosis에 관(關)한 실험적(實驗的) 연구(硏究))

  • Cho, Hee-Chul;Lee, Sun-Gu;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.7 no.2
    • /
    • pp.5-17
    • /
    • 2004
  • Objective : In order to measure the efficacy of cultivated wild ginseng distilled herbal acupuncture by concentration level, we've treated A549 human lung cancer lines with different concentrations of cultivated wild ginseng distilled herbal acupuncture and examined mRNA and proteins which take parts in apoptosis. Methods : A549 human lung cancer lines were treated with various concentration levels of cultivated wild ginseng distilled herbal acupuncture and cell toxicity was carefully examined. From the analysis of DNA fragmentation, RT-PCR and Western blot, manifestation of mRNA and proteins which are associated with apoptosis were inspected. Results : The following results were obtained on apoptosis of A549 human lung cancer lines after administering various concentration levels of cultivated wild ginseng distilled herbal acupuncture. 1. Measuring cell toxicity of lung cancer cells, strong cell toxicity was detected at high concentration level(1000ul, 1200ul), but no consistent concentration dependent reliance was detected. 2. Through DNA fragmentation, we were able to confirm cell destruction in all groups. 3. Experiment groups treated with cultivated wild ginseng distilled herbal acupuncture showed inhibition of Bcl-2 and COX-2 at mRNA and Protein level, whileas increase of Bax was shown. 4. Manifestation of p21, p53, Cyclin E, and Cyclin Dl were confirmed in all groups. 5. Extrication of Cytochrome C was detected at all groups, as well as increased activity of the enzyme caspase-3 and caspase-9, and PARP fragmentation were confirmed. Conclusion : According to the results, we can carefully deduce cell destruction of A549 human lung cancer lines were induced by Apoptosis. At the fixed level, cultivated wild ginseng distilled herbal acupuncture showed decrease of Bcl-2 and COX-2, as well as increase of Bax. Since cultivated wild ginseng distilled herbal acupuncture increases manifestation of p21, p53, Cyclin E, and Cyclin Dl, it affects cellular cycle and through these phenomena, we can consider extrication of Cytochrome C, increase of caspase, and PARP fragmentation are the results.

An Empirical Study on Real-Time Temperature and Concentration Measurement Through Optical Absorption Characteristic Analysis of Gas in a Large Combustion System (가스의 광 흡수 특성 분석을 통한 대형 연소시스템 내 실시간 온도 및 농도 계측에 관한 실증 연구)

  • Park, Jiyeon;So, Sunghyun;Park, Daeguen;Ryu, Changkook;Lee, Changyeop;Yoo, Miyeon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.29-38
    • /
    • 2020
  • It is practically difficult to accurately measure the temperature and concentration of a large combustion systems at industrial sites in real time. Temperature measurement using thermocouple, which are mainly used, is a point-measuring method that is less accurate and less reliable to analyze the wide area range of inner combustion system, and has limitations to internal accessibility. In terms of concentration analysis, most measurement methods use sampling method, which are limited by the difficulty of real-time measurement. As a way to overcome these limitations, laser-based measurement methods have been developed continuously. Laser-based measurement are line-average measurement methods with high representation and precision, which are beneficial for the application of large combustion systems. In this study the temperature and concentration were measured in real time by water vapor and oxygen generated during combustion using Tunable Diode Laser Absorption Spectroscopy (TDLAS). The results showed that the average temperature inside the combustion system was 1330℃ and the mean oxygen concentration was 3.3 %, which showed similar tendency with plant monitoring data.

Product Image Concentration System as a Design Strategy to Build Corporate Brand Image (기업 브랜드 이미지 구축을 위한 디자인 전략으로서의 제품 이미지 집중 체계)

  • Kim, Hyun
    • Archives of design research
    • /
    • v.16 no.2
    • /
    • pp.375-384
    • /
    • 2003
  • This study is on the strategy for establishing successful corporate brand image, by understanding the need for increasing brand value based on the level of brand recognition. In order to carry this out, the PICS (Product Image Concentration System) is suggested, which includes Brand Image Analysis on a high-level, Product Image Programming based on the result of the image analysis, and Product Image Coherency Assessment and Management, resulting in setting up a guideline for gaining competitive advantage and brand management. Brand Image Analysis is a method that utilizes image association to understand brand disposition by analyzing the association pattern among available visual materials to measure the corporate and brand image inclinations. As the next step, Product Image Programming establishes design philosophy and principles based on the analysis of brand image, and the Visual Programming is a process for visualizing the intended product image direction. Lastly, Product Image Coherency Assessment examines whether to incorporate design philosophy and principles or not to arrive at an agreed evaluation criteria for developing designs coherent with the brand image. The PICS (Product Image Concentration System) is a practical method for increasing a company' competitive advantage and managing brand. The expectation on this system is to provide a guideline for applying brand image in design process more objectively. For further study, diversification of image spectrum based on expressive keywords and comparative analysis on images as well as a product image interpretation program to understand the order of visual materials will be necessary.

  • PDF

Characteristics of Exposure Distribution to Hazard Factors in Indoor Swimming Pool Activity Areas in Gwangju (수영장 활동공간 내 유해인자 노출특성 연구)

  • Lee, Youn-Goog;Kim, Nan-Hee;Choi, Young-Seop;Kim, Sun-Jung;Park, Ju-Hyun;Kang, Yu-Mi;Bae, Seok-Jin;Seo, Kye-Won;Kim, Jong-Min
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Objective: This study is designed to measure the concentration of DBPs (disinfection by-products) in pool water and in air and to estimate the carcinogenic potential through the evaluation of inhalation exposure. Methods: The subjects were six indoor swimming pools with many users in Gwangju. Samples of pool water and indoor air were taken every one month from August 2018 to August 2019 and analyzed for eight swimming pool standards. Three-liter air samples were collected and the VOCs were analyzed using GC/MS directly connected to thermal desorption. Results: pH was 6.8-7.5 and the concentration of free residual chlorine in pool water was 0.40-0.96 ?/ℓ. Physicochemical test items such as KMnO4 consumption and heavy metal items such as Aluminum met existing pool hygiene standards. No VOC materials were detected except for the DBPs. The concentration of THMs in the pool water was 11.05-41.77 ㎍/L and the THMs mainly consist of Chloroform (63-97%) and BDCM (3-31%). The concentration of indoor air THMs is 13.24-32.48 ㎍/㎥ and consists of Chloroform. The results of carcinogenic assessment of chloroform in the indoor swimming pool via inhalation exposure were 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA. Conclusions: The concentration of THMs in the pool water is 11.05-41.77 ㎍/L, most of which is chloroform. In addition, the concentration of indoor air THMs is 13.24-32.48 ㎍/㎥. The result of carcinogenic assessment of chloroform was 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA.

Unsteady Mass Transfer Around Single Droplet Accompanied by Interfacial Extraction Reaction of Succinic Acid (숙신산 추출반응이 일어나는 단일 액적계에서의 비정상상태 물질 전달)

  • Jeon, Sangjun;Hong, Won Hi
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1021-1026
    • /
    • 2012
  • The transient mass transfer in a single droplet system consisting of 1-octanol (continuous phase)/aqueous succinic acid solution (dispersed phase) was investigated in the presence of chemical reaction, which is acid/anion exchange reaction of succinic acid and tri-n-octylamine (TOA). This succinic acid extraction by TOA can be considered to occur at the interface between organic and aqueous phase, that is, heterogeneous reaction system. The basic properties of the system such as viscosity, density, distribution coefficient, terminal velocity of droplet, and diffusion coefficient were measured experimentally or calculated theoretically, and used for theoretical calculation of characteristic parameters of mass transfer later. The effects of succinic acid concentration on the terminal velocity was negligible in the existence of TOA, although the terminal velocity increases with succinic acid concentration in the absence of TOA. On the contrary, the terminal velocity decreases with TOA concentration. While droplets falls through organic phase, the trajectory of droplets is observed to oscillate around its vertical path. A mass trnasfer cell was prepared to monitor the mass transfer behavior in a single droplet and used to measure the mean concentration of succinic acid inside droplet. The results are expressed with dimensionless parameters. Under 50 g/L succinic acid condition, the system with 0.1 mol/kg TOA showed that the molar flux decreases in proportion to the decrease of concentration gradient, while in the case of 0.5 mol/kg TOA Sh increases rapidly with time indicating the molar flux of succinic acid decreases relatively slowly compared to the decrease in concentration gradient.

EFFECTS OF PHOSPHORIC ACID CONCENTRATION ON DEPTH OF ETCH AND SHEAR BOND STRENGTH OF ORTHODONTIC BRACKETS TO BOVINE ENAMEL (인산농도가 소의 법랑질에서 부식깊이와 브라켓 전단결합강도에 미치는 영향)

  • Kim, Soo-Cheol;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.341-353
    • /
    • 1995
  • Previous study had shown the diversities in the propriety for optimal bond strength on the concentration of the etchant. The aim of present study in vitro was to evaluate and compare the shear bond strength of orthodontic brackets to enamel and to measure the depth of etch on the phosphoric acid concentrations. A hundred and seventy six extracted bovine lower centrals were ground to yield flat surfaces and etched by the concentration $0%,\;5%,\;10%,\;20%,\;30%,\;40%,\;50%,\;60%,\;70%,\;80%\;and\;85\%$ of phosphoric acid respectively during 60 seconds. The shear bond strength of orthodontic brackets, the depth of etch and surface roughness of the enamel were measured, and scanning electron microscopic observations on the etched enamel surfaces were carried out. The data obtained from the very experiments were processed and statistically analyzed and evaluated. The gradual increase in the depth of etch to enamel as the accretion of the concentration of the phosphoric acid upto $40-50\%$ and decline henceforth were manifested. The surface roughness showed no correlation with the depth of etch, yet moderate correlation with the shear bond strength of brackets. Scanning electron microscopic investigation revealed that morphological patterns of the etched enamel surfaces for $5\%\;to\;40\%$ of concentrations were even and homogenous, and those for $50\%$ as well as $60\%$ exhibited the overetched and unhomogenous. The shear bond strengths kom $10\%\;to\;60\%$ of concentration showed no statistically significant differences. It was suggested that the shear bond strengths at $5\%\;and\;70\%$ were sufficient to tolerate the force levels of the ordinary orthodontic treatment notwithstanding to be significantly lower than those from $10\%\;to\;60\%$ phosphoric acid solution.

  • PDF

Comparison of the Fertility of Stream Waters Depending on the Drainage Systems in the Lake Shihwa Watershed, Korea (시화호 유역에서 배수시스템별 하천수의 비옥도 비교)

  • Shin, Jae-Ki;Kim, Dong-Sup;Kang, Chang-Keun;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.381-388
    • /
    • 2003
  • The fertility of stream water in major streams of the Lake Shihwa Watershed was compared using water analyses and algal growth potential test (AGPT) in typical drought seasons from December 2001 to April 2002, The water quality varied considerably depending on streams. These streams were very rich in inorganic nutrients that the nutrient levels and characteristics of each stream could be easily determined. Through AGPT, 63.6% of growth was observed in the average values of each stream, with non-growth accounting for 36.4%. AGPT results showed that 40.9% of the 22 stations were in hypertrophic condition and 54.5% in eutrophic condition. AGPT values were significantly correlated with TIN, $NH_4$, and SRP (p <0.001); compared to other nutrients, however, they were more related to SRP and $NH_4$. Moreover, the values increased with high concentration of N and P and low N/P ratios. Nonetheless, the values were more dependent on P concentration than N concentration. This suggests that the effect of P on the water quality of lake situated in downstream may serve as a potential indicator of phytoplankton development. Depending on the drainage pattern of streams, the wastewaters of wastewater treatment plant (WwTP) and untreated wastewater (UTW) were found to have 53.4% and 46.6%, respevtively, of TIN, 51.9% and 48.1% of $NH_4$, 62.9% and 37.1% of $NO_3$, 62.6% and 37.4% of SRP, and 44.1% and 55.9% of SRSi. The AGPT value was 51.1% in WwTP wastewater and 48.9% in UTW wastewater, the concentration of WwTP wastewater was slightly higher. For untreated wastewaters flowing into the constructed wetland and into the lake, TIN accounts for 43.0% and 57.0%, respectively, of nitrogen components, $NH_4$ 44.4% and 55.6%, $NO_3$ 39.6% and 60.4%, SRP 53.5% and 46.5%, and SRSi 52.3% and 47.7%, respectively. The AGPT value was 58.0% in the constructed wetland and 42.0% in Lake Shihwa; the concentration in streams flowing into the wetland was slightly higher. Therefore, Persistent and large development of phytoplankton in Lake Shihwa cannot be prevented unless a measure tophytoplankton control is implemented. This is because the concentration of nutrients in specific streams flowing into the lake is very high, even though the inflow of water is low.

Exposure Assessment of Hazardous gases in Confined Spaces (밀폐공간 종류별 유해가스 발생 농도 평가)

  • Park, Hyunhee;Yoo, Kye-mook;Ham, Seung-hon;Chung, Kwang-Jae;Shin, Min-a;Lee, Koo-yong;Jang, Kyung-jo;Yoon, Chung-sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.4
    • /
    • pp.381-389
    • /
    • 2009
  • Confined spaces are inherently dangerous workplace and many fatal and nonfatal accidents have been reported. Even though these accidents occur in various kinds of confined spaces, there has rarely been reported on the health hazard agent, i.e., the types of gases and their concentration ranges. Therefore in this study, we evaluated several toxic and asphyxiating gas concentrations in various confined spaces. We surveyed 57 manholes, 3 sewage treatment plants, 2 yellow radish manufacturing companies and 7 barges to measure the concentrations of oxygen($O_2$), hydrogen sulfide($H_2S$), carbon monoxide(CO), ammonia($NH_3$). Lower Explosion Limits(LEL) and Volatile Organic Compounds (VOCs). Those four types of confined spaces occupies 56% of accidents during last 9 years in Korea. In 57 manholes, the concentration varied according to the types of manholes; rainfall and sewage, and by location; residential and industrial areas. Sewage manhole in industrial area was evaluated as the most hazardous than other types of manhole like rainfall manholes, residential sewage manholes. The highest $H_2S$ concentration and the lowest $O_2$ concentration at sewage manhole in industrial area were 300 ppm, 8.7% respectively. In 3 sewage treatment plants, $H_2S$ and $NH_3$ concentrations were reached up to the 500 ppm and 200 ppm respectively. Two yellow radish manufacturing companies showed the concentrations of 316 ppm, 505.2 ppm, 90 ppm and 15.7% for $H_2S$, CO, VOCs and $O_2$, respectively. Seven barges showed 15.9%~20.9% oxygen concentration. Gas species and concentration ranges varied by the types and location of confined spaces; CO, $H_2S$, $O_2$ could be hazardous in manhole, especially manhole connected to sewage plants. CO, $H_2S$, LEL, $O_2$, $NH_3$ should be controlled in sludge silo and sluge pumping confined spaces in sewage treatment plant. The activity of lifting out radish from the storage tank was evaluated more hazardous rather than the other activities in yellow radish manufacturing industry. The employers must conduct the survey to identify all possible confined spaces in their local workplace prior to performing the tasks. At the national level to reduce the accidents in the confined spaces, we suggest that systemic approach and active education program including possible hazards, standard operation procedures, ventilation plan, and personal protective equipment in confined spaces should be implemented.

Measurement of Al Concentration in Liquid Zinc by E.M.F Method with $CaF_2$ ($CaF_2$ 기전력법에 의한 용융아연 중 알루미늄 농도의 측정)

  • Park Jin Sung;Kim Hang Soo;Jung Woo-Gwang;Katayama I.;Kim Jong Sang
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.204-210
    • /
    • 2000
  • The control of dissolved aluminum concentration in the hot dip zinc galvanizing bath is greatly important in producing galvannealed steel sheets. The purpose of present study is to provide basic data for measurement of the aluminum concentration in site in hot dip zinc bath at the temperature of $460^{\circ}C\~500^{\circ}C$ using $CaF_2$ solid electrolyte sensor with three kinds of reference electrode. Good workability and stability of the sensor were confirmed with the $Bi+BiF_3$ reference electrode from the emf measurement. In order to measure the aluminum concentration in Zn-Al bath, the galvanic cell of fluorine ion was constructed with $CaF_2$ solid electrolyte as follows; $$(-)W|Zn-Al,\;AlF_3|CaF_2|Bi,BiF_3|W(+)$$. The emf measurement was made at the temperature of $460\pm10^{\circ}C$ in the Zn-Al bath. The following correlationship between aluminum concentration and emf was obtained by the least square regression analysis; $$E/mV=56.795log[\%Al]+1881.7\;R=0.9704$$,$$0.026wt\%{\leq}[\%Al]{\leq}0.984wt\%$$

EVALUATION OF FLUORIDE-RELEASING CAPACITY FROM POLYVINYL ALCOHOL POLYMER TAPE SUPPLEMENTED WITH NAF IN ORAL CAVITY (폴리비닐알코올 기반 고분자 불소 함유 테이프의 구강 내 불소 유리 성능 평가)

  • Lee, Ka-Young;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.2
    • /
    • pp.89-97
    • /
    • 2013
  • The purpose of this study is to investigate fluoride release in the oral cavity from polymer adhesive tape which is NaF coated PVA. 45 healthy adults were divided into 3 groups by the type of topical fluoride applied: 60seconds taste$^{(R)}$ APF gel (group 1), FluoroDose$^{(R)}$ varnish (group 2) and NaF-PVA (group 3). Topical fluoride was applied to the facial surface of maxillary 12 teeth and unstimulated whole saliva was collected to measure fluoride release after 1, 3, 6, 12, 24, and 48 hours. Fluoride-sensitive electrode was used for measuring the fluoride concentration in the saliva samples. All three groups showed significantly higher value for fluoride concentration than the baseline after 1 and 3 hours (p < 0.05). After 6 hours, group 3 showed significantly higher fluoride concentration than the baseline (p < 0.05) and also showed significantly higher value for fluoride concentration than group 1 and group 2. Between group 1 and group 2, however, there was no significant difference statistically with respect to fluoride concentration value (p > 0.05).