• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.025 seconds

Studies on the Biological Function and Antibacterial Effect of Lactoperoxidase System in Raw Milk 2. Antibacterial Effect of Lactoperoxidase System Against Listeria monocytogenes (우유내의 LP system의 생리기능 및 항균성에 관한 연구 2. Listeria monocytogenes에 대한 항균효과)

  • 정충일;남은숙;김대원;이원창;정동관
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.2
    • /
    • pp.83-86
    • /
    • 1998
  • This study was carried out to measure the antibacterial effect of lactoperoxidase system against L. monocytogenes. When the initial inoculum levels ($10^{2},\;10^{4},\;10^{7}\;CFU/ml$), concentration of LP (10 ppm, 20 ppm, 30 ppm), culture media (TSB-YE, UHT milk) and storage temperatures ($5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C$) were set up differently for the experiment and the antibacterial effect was compared, the highest antibacterial effect of LP system was shown at $10^{2}\;cfu/ml$ of initial inoculum level, 10 ppm of LP concentration and $5^{\circ}C$ of incubaction temperature. The antibacterial effect of LPS in UHT milk was similar to that in Tryptic soy broth.

  • PDF

Determination of NaOH, $Na_2CO_3$ and $Na_2S$ Concentration in a Naphtha Cracking Process by FT-NIR Spectroscopy (FT-NIR를 이용한 Naphtha Cracking 공정중 NaOH, $Na_2CO_3$$Na_2S$ 정량분석)

  • Jang, Mijin;Kim, Hyunwook;Cho, Ilyoung
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.448-451
    • /
    • 1998
  • The feasibility of using FT-NIR (Fourier Transform Near Infrared) spectrometer to measure NaOH, $Na_2CO_3$ and $Na_2S$ concentration in a naphtha cracking process, and an outline of the method development to identify spectral feature of the hydroxide whose band is overlapped by a strong water absorption were demonstrated. For measuring NaOH, $Na_2CO_3$ and $Na_2S$, FT-NIR spectrometer is a rapid and possible alternative to the current titration method with a standard deviation of 0.1.

  • PDF

Diagnostic Paper Chip for Reliable Quantitative Detection of Albumin using Retention Factor (체류 인자를 이용한, 알부민의 정량 분석용 종이 칩)

  • Jeong, Seong-Geun;Lee, Sang-Ho;Lee, Chang-Soo
    • KSBB Journal
    • /
    • v.28 no.4
    • /
    • pp.254-259
    • /
    • 2013
  • Herein we present a diagnostic paper chip that can quantitatively detect albumin without external electronic reader and dispensing apparatus. We fabricated a diagnostic paper chip device by printing wax barrier on the paper and wicking it with citrate buffer and tetrabromophenol blue to detect albumin in sample solution. The paper chip is so simple that we dropped a sample solution at sample pad and measure the ratio of two travel distances of the sample solvent and albumin under the name of retention factor. Our result confirmed that the retention factor was constant in the samples with same concentration of albumin and useful determinant for the measurement of albumin concentration. The paper chip is affordable and equipment-free, and close to ideal point-of-care test in accordance with the assured criteria, outlined by the World Health Organization. We assume that this diagnostic paper chip will expand the concept of colorimetric determination and provide a inexpensive diagnostic method to aging society and developing country.

Effects of taeeumjoweetang Herbal-Acupuncture on plasma and liver lipid composition and antioxidative capacity in rat fed high fat diet (태음조위탕(太陰調胃湯) 약침(藥鍼)이 고지방 급여 흰쥐의 혈장 및 간장의 지질구성과 항산화능에 미치는 영향)

  • Lim, Yun-Taek;Lee, Joon-Moo
    • Korean Journal of Acupuncture
    • /
    • v.22 no.2
    • /
    • pp.151-161
    • /
    • 2005
  • Objectives : In order to measure the Effects of taeeumjoweetang Herbal- Acupuncture at joksamri(ST36) and kwanweun(CV4) on liver and plasma lipid composition and antioxidative capacity in rat fed high fat diet. Results : Concentrations of plasma triglyceride, total cholesterol and LDL-cholesterol showed a tendency to increase in the high fat diet group. However Herbal-Acupuncture groups showed a lower values than control groups. HDL-cholesterol showed a tendensy to decrease in high 131 fat diet groups and in high fat diet groups, these values showed no significantly different. Liver total cholesterol values showed no significantly different in all treatment groups. Triglyceride concentration showed a high value in control group and other treatment groups showed no significantly different. plasma GOT and GPT values showed a tendency to increase in high fat diet group. however these values decreased in Herbal-Acupuncture group. The concentration of TBARS in liver and plasma showed a high values in high fat diet group, however these values showed a tendency to decrease in aqua- acupuncture group. Glutathione peroxidase, superoxide dismutase and catalase activity values showed a low values in high fat diet group, however these values showed a tendency to increase in Herbal-Acupuncture group.

  • PDF

The Effect of Electrolytes on Polshing Behavior in Cu ECMP (Cu ECMP 공정에서 전해액이 연마거동에 미치는 영향)

  • Kwon, Tae-Young;Kim, In-Kwon;Kim, Tae-Gon;Cho, Byung-Gwun;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.18 no.6
    • /
    • pp.334-338
    • /
    • 2008
  • The purpose of this study is to characterize various electrolytes on electrochemical mechanical planarization (ECMP). The ECMP system was modified from conventional CMP system to measure the potentiodynamic curve and removal rate of Cu. The potentiodynamic curves were measured in static and dynamic states in investigated electrolytes using a potentiostat for the evaluation of the polishing behavior on ECMP. KOH (alkaline) and $NaNO_3$ (salt) were selected as electrolytes which have high conductivity. In static and dynamic states, the corrosion potential decreased and the corrosion current increased as a function of the electrolyte concentration. But, the electrochemical reaction was prevented by mechanical polishing effect in the dynamic state. The static etch and removal rate were measured as functions of concentration and applied voltage. When $NaNO_3$ was used, the dissolution was much faster than that of KOH. It was concluded that the removal rate was strongly depended on electrochemical dissolution. The removal rate increased up to 350 nm/min in $NaNO_3$ based electrolyte.

Deuterium Naturally Present in Solvent and Site-Specific Isotope Population of Deuterium-Enriched Solute

  • Hwang, Ryeo Yun;Han, Oc Hee;Lee, Juhee;Kim, Eun Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.2959-2962
    • /
    • 2013
  • As the concentration of aqueous $CD_3OH$ solutions was decreased, the OD peaks in $^2H$ NMR spectra grew relative to the $CD_3$ peaks. Isotope impurity for OH groups of $CD_3OH$ and deuterium naturally present in water contributed to the OD peaks. Using these peak area data, the site-specific isotope populations of isotope enriched chemicals were measured. In addition, the method using both $^1H$ and $^2H$ NMR spectroscopy was demonstrated with neat $CD_3OH$ to measure the site-specific isotope populations. The results indicate that although it represents only ~0.015% of hydrogen isotopes, the deuterium naturally present in solvents cannot be ignored, especially when the concentration of deuterium-enriched solutes is varied. Proton/deuteron exchange between methyl and methyl/hydroxyl groups was confirmed to be negligible, while that among hydroxyl groups was detectable.

Effects of Testing and Storage Environments on the Blood Glucose Measurements by Using Phosphazene Diagnostic Membranes (측정환경과 보관환경이 포스파젠 진단막을 이용한 혈당측정에 미치는 영향)

  • Kwon, Suk-Ky
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.301-308
    • /
    • 2012
  • Phosphazene diagnostic membranes were prepared to measure blood glucose level of diabetics. Final absorbances at 680nm through activated phosphazene membranes were measured at various temperature and humidity by varing concentration of glucose in blood. Measuring temperature and humidity did not seriously affected the end-point results of varing absorbance values as time (K/S). The effects of storage temperatures on the measurements of glucose concentration were studied after activated phosphazene diagnostic membranes were stored at various temperatures for 3 days, 1 week, 3 weeks, and 5 weeks. The stabilities of phosphazene dianostic membranes were confirmed even at RH 80%.

Minimal systems analysis of mitochondria-dependent apoptosis induced by cisplatin

  • Hong, Ji-Young;Hara, Kenjirou;Kim, Jun-Woo;Sato, Eisuke F.;Shim, Eun Bo;Cho, Kwang-Hyun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.4
    • /
    • pp.367-378
    • /
    • 2016
  • Recently, it was reported that the role of mitochondria-reactive oxygen species (ROS) generating pathway in cisplatin-induced apoptosis is remarkable. Since a variety of molecules are involved in the pathway, a comprehensive approach to delineate the biological interactions of the molecules is required. However, quantitative modeling of the mitochondria-ROS generating pathway based on experiment and systemic analysis using the model have not been attempted so far. Thus, we conducted experiments to measure the concentration changes of critical molecules associated with mitochondrial apoptosis in both human mesothelioma H2052 and their ${\rho}^0$ cells lacking mitochondrial DNA (mtDNA). Based on the experiments, a novel mathematical model that can represent the essential dynamics of the mitochondrial apoptotic pathway induced by cisplatin was developed. The kinetic parameter values of the mathematical model were estimated from the experimental data. Then, we have investigated the dynamical properties of this model and predicted the apoptosis levels for various concentrations of cisplatin beyond the range of experiments. From parametric perturbation analysis, we further found that apoptosis will reach its saturation level beyond a certain critical cisplatin concentration.

An Investigation on Concentration of Airborne Microbes in a Hospital (병원내 공기중 미생물의 농도에 관한 조사연구)

  • 최종태;김윤신
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 1993
  • A survey was conducted to measure concentration of airborne microbe in a hospital using RSC air sampler during October~November 1991.The result was as follows: 1) In an agar strip GK-A media for total counts of microbial particles. The highest count were 1384 CFU/m$^3$ in the main lobby, followed by 912 CFU/m$^3$, in the obstetric room, 688 CFU/m$^3$ in 1CU. By gram staining, the distribution for organisms in the air were shown 74.1% in gram possitive cocci followed by 16.8%, in gram possitive bacilli 6.7% in gram negative bacilli and 4.7% in yeast, but low organism was detected in recovery room with 194 CFU/m$^3$. 2) In agar strip S media for Staphylococci the count at the main lobby was detected in the recovery room with 92 CFU/m$^3$, Tests of coagulase were negative Staphylococci with 78%, and positive Staphylococci with 22%. The Staphylococci were highly resistance to penicillin, ampicillin and sensitive to amikacin, cefazolin, gentamycin and chloramphenicol. 3) In agar strip C media for coliform bacteria the colony counts at the main lobby was 139 CFU/m$^3$ and treatment room was 190 CFU/m$^3$, most frequently isolated microorganisms were non fermentative bacilli. 4) In agar strip HS media for yeast and molds. Most frequently colony counts 17~76 CFU/m$^3$, 0.5% lactophenol cotton blue stains were shown unidentified 77.2%, 8.1%, in Penicillium 8.1% in Aspergillus, and 3.8% in mucor.

  • PDF

Heat & Cool Injection Molded Fresnel Lens Solar Concentrators (가열-냉각 사출성형 방식을 적용한 집광형 프레넬렌즈)

  • Jeong, Byeong-Ho;Min, Wan-Ki;Lee, Kang-Yeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.283-289
    • /
    • 2014
  • A Fresnel lens is an optical component which can be used as a cost-effective, lightweight alternative to conventional continuous surface optics. Fresnel lens solar concentrators continue to fulfill a market requirement as a system component in high volume cost effective Concentrating Photovoltaic (CPV) electricity generation. The basic principles of the fresnel lens are reviewed and some practical examples are described. To investigate the performance space of the Fresnel lens, a fast simulation method which is a hybrid between raytracing and analytical computation is employed to generate a cache of simulation data. Injection molders are warming up to the idea of cycling their tool surface temperature during the molding cycle rather than keeping it constant. Heat and cool process are now also finding that raising the mold wall temperature above the resin's glass-transition or crystalline melting temperature during the filling stage and product performance in applications from automotive to packaging to optics. This paper deals with the suitability of Fresnel lenses of imaging and non-imaging designs for solar energy concentration. The concentration fresnel lens confirmed machinability and optical transmittance and roughness measure through manufactured the prototype.