References
- Nay, R. (2013) Public Health for an Aging Society. Aust. Nz. J. Publ. Heal. 37: 98-98. https://doi.org/10.1111/1753-6405.12021
- Gervais, L., N. de Rooij, and E. Delamarche (2011) Microfluidic Chips for Point-of-Care Immunodiagnostics. Adv. Mat. 23: H151-H176. https://doi.org/10.1002/adma.201100464
- Chin, C. D., V. Linder, and S. K. Sia (2007) Lab-on-a-chip devices for global health: Past studies and future opportunities. Lab on a Chip. 7: 41-57. https://doi.org/10.1039/b611455e
- Peeling, R. W., K. K. Holmes, D. Mabey, and A. Ronald (2006) Rapid tests for sexually transmitted infections (STIs): the way forward. Sex Transm Infect. 82: V1-V6. https://doi.org/10.1136/sti.2006.024265
- Hinberg, I. H., L. Katz, and L. Waddell (1978) Sensitivity of in vitro diagnostic dipstick tests to urinary protein. Clin. Biochem. 11: 62-64. https://doi.org/10.1016/S0009-9120(78)90719-1
- Davis, M. M., P. J. Schuhmann, and M. E. Lovelace (1948) Acid-base reactions in organic solvents; behavior of some halogenated derivatives of phenolsulfonephthalein with different classes of organic bases in benzene. J. Res. Natl. Bur. Stand. 41: 27-40. https://doi.org/10.6028/jres.041.005
- Samiey, B., K. Alizadeh, M. F. Mousavi, ands N. Alizadeh (2005) Study of kinetics of bromophenol blue fading in alcohol-water binary mixtures by SESMORTAC model. B. Kor. Chem. Soc. 26: 384-392. https://doi.org/10.5012/bkcs.2005.26.3.384
- Shapovalov, S. A., V. L. Koval, T. A. Chernaya, A. Y. Pereverzev, N. A. Derevyanko, A. A. Ishchenko, and N. O. Mchedlov-Petrossyan (2005) Association of indopolymethine cyanine cations with anions of sulfonephthalein and xanthene dyes in water. J. Brazil Chem. Soc 16: 232-240. https://doi.org/10.1590/S0103-50532005000200017
- Congdon, R. W., G. W. Muth, and A. G. Splittgerber (1993) The binding interaction of coomassie blue with proteins. Anal. Biochem. 213: 407-413. https://doi.org/10.1006/abio.1993.1439
- Suzuki, Y. (2001) Guidance for selecting the measurement conditions in the dyebinding method for determining serum protein: Theoretical analysis based on the chemical equilibium of protein error. Anal. Sci. 17: 1263-1268. https://doi.org/10.2116/analsci.17.1263
- Gyure, W. L. (1977) Comparison of several methods for semiquantitative determination of urinary protein. Clin. Chem. 23: 876-879.
- Arredondo, A. (2013) Diabetes: a global challenge with high economic burden for public health systems and society. Am. J. Public Health. 103: e1-2.
- Cate, D. M., W. Dungchai, J. C. Cunningham, J. Volckens, and C. S. Henry (2013) Simple, distance-based measurement for paper analytical devices. Lab. Chip. 13: 2397-2404. https://doi.org/10.1039/c3lc50072a
- Washburn, E. W. (1921) Note on a method of determining the distribution of pore sizes in a porous material. Proc. Natl. Acad. Sci. USA 7: 115-116. https://doi.org/10.1073/pnas.7.4.115
- Carrilho, E., A. W. Martinez, and G. M. Whitesides (2009) Understanding wax printing: a simple micropatterning process for paperbased microfluidics. Anal. Chem. 81: 7091-7095. https://doi.org/10.1021/ac901071p
- Compton, S. J. and C. G. Jones (1985) Mechanism of dye response and interference in the Bradford protein assay. Anal. Biochem. 151: 369-374. https://doi.org/10.1016/0003-2697(85)90190-3
- Wei, Y. J., K. A. Li, and S. Y. Tong (1996) The interaction of Bromophenol Blue with proteins in acidic solution. Talanta. 43: 1-10. https://doi.org/10.1016/0039-9140(95)01683-X
Cited by
- Analysis of Morphological Change of Polar Bacterium using Microfluidic Device with Temperature Gradient vol.29, pp.4, 2014, https://doi.org/10.7841/ksbbj.2014.29.4.278
- Paper-Based Device for Naked Eye Urinary Albumin/Creatinine Ratio Evaluation vol.5, pp.4, 2013, https://doi.org/10.1021/acssensors.0c00050
- 회전각도를 이용한 알부민 농도 측정용 3차원 종이 칩 vol.58, pp.2, 2013, https://doi.org/10.9713/kcer.2020.58.2.286