• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.029 seconds

Ultrasonic Velocity and Absorption Measurements in an Aqueous Solution of Poly(sodium 4-styrenesulfonate)

  • Rae Jong-Rim
    • Macromolecular Research
    • /
    • v.12 no.6
    • /
    • pp.559-563
    • /
    • 2004
  • Both the ultrasonic velocity at 3 MHz and the absorption coefficient in the frequency range from 0.2 to 2 MHz were measured for aqueous solutions of poly(sodium 4-styrenesulfonate) over the concentration range from 5 to $25\%$ (by weight). The pulse echo overlap method was employed to measure the ultrasonic velocity over the temperature range from 10 to $90^{\circ}C;$ the high-Q ultrasonic resonator method was used for the measurement of the absorption coefficient at $20^{\circ}C.$ The velocities exhibited their maximum values at ca. 55, 59, 63, 67, and $71^{\circ}C.$ for the 25, 20, 15, 10, and $5\%$ solutions, respectively. The velocity increased with respect to the poly(sodium 4-styrene-sulfonate) concentration at a given temperature. A study of the concentration dependence of the both the relaxation frequency and amplitude indicated that the relaxation at ca. 200 kHz is related to structural fluctuations of the polymer molecules, such as the segmental motions of the polymer chains and that the relaxation at ca. 1 MHz resulted from the proton transfer reactions of the oxygen sites of $SO_3.$ Both the absorption and the shear viscosity increase upon increasing the polymer concentration, but they decrease upon increasing the temperature.

Detection of Face Direction by Using Inter-Frame Difference

  • Jang, Bongseog;Bae, Sang-Hyun
    • Journal of Integrative Natural Science
    • /
    • v.9 no.2
    • /
    • pp.155-160
    • /
    • 2016
  • Applying image processing techniques to education, the face of the learner is photographed, and expression and movement are detected from video, and the system which estimates degree of concentration of the learner is developed. For one learner, the measuring system is designed in terms of estimating a degree of concentration from direction of line of learner's sight and condition of the eye. In case of multiple learners, it must need to measure each concentration level of all learners in the classroom. But it is inefficient because one camera per each learner is required. In this paper, position in the face region is estimated from video which photographs the learner in the class by the difference between frames within the motion direction. And the system which detects the face direction by the face part detection by template matching is proposed. From the result of the difference between frames in the first image of the video, frontal face detection by Viola-Jones method is performed. Also the direction of the motion which arose in the face region is estimated with the migration length and the face region is tracked. Then the face parts are detected to tracking. Finally, the direction of the face is estimated from the result of face tracking and face parts detection.

Anti-Bacterial Effects of Basil Oil on Streptococcus mutans and Porphyromonas gingivalis (Streptococcus mutans와 Porphyromonas gingivalis에 대한 Basil Oil의 항균효과)

  • Yoon, Hyunseo;Park, Chungmu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.3
    • /
    • pp.131-139
    • /
    • 2018
  • Purpose : The study objective was to assess the antibacterial activity of essential oil of basil against S. mutans and P. gingivalis and to explore its potential to prevent dental caries and peridontal disease. Method : Essential oil of basil, extracted using steam distillation, was diluted with triple distilled water and Tween 20 to generate samples at various concentration, that is 30%, 50%, and 70% (v/v). Strains of S. mutans and P. gingivalis were incubated in the medium under anaerobic condition. Broth microdilution susceptibility testing and plate incubation diffusion were utilized to determine the minimum inhibitory concentration (MIC) and to measure antibacterial activity, respectively. Result : An upsurge in antibacterial activity was seen to correlate with and increase in the concentration used for both bacterial strains, but was more significant with S. mutans. A statistically significant growth inhibition effect and reduction in the number of colonies was also observed with both strains dependent on the concentration used following 24 hours of incubation. Conclusion : Thus, the current study finding was that essential oil of basil was effective against dental caries and periodontal disease and could be used in dentifrice to help prevent oral disease.

Cyclic AMP Receptor Protein Adopts the Highly Stable Conformation at Millimolar cAMP Concentration (높은 cAMP 농도에서 cAMP 수용성 단백질의 열 안정화)

  • Kang, Jong-Baek;Choi, Young
    • Journal of Life Science
    • /
    • v.13 no.5
    • /
    • pp.751-755
    • /
    • 2003
  • Cyclic AMP receptor proteins(CRP) activate many genes in Escherichia coli by binding of cAMP with not fully known mechanism. CRP existed as apo-CRP in the absence of cAMP, $CRP;(cAMP)_2$$_2$ at low(micromolar) cAMP concentration, or $CRP;(cAMP)_4$ at high(millimolar) concentration of cAMP. This study is designed to measure the thermal stability of S83G CRP, which substituted glycine for serine at amino acid 83 position, with CD spectrapolarimeter at 222nm by the constant elevation of temperature from $20^{\circ]C\; to\; 90^{\circ}C\; at\; 1^{\circ}C/min$. The non-linear regression analysis showed that melting temperatures were 68.4, 72.0, and $82.3^{\circ}C$ for no cAMP, 0.1mM cAMP, and 5mM cAMP, respectively. Result showed the strong thermal stability of CRP by binding of additional cAMP molecules to region between the hinge region and helix-turn-helix(HTH) motif at 5mM cAMP concentration.

A Study on the Measurement of Industry Agglomeration for the Census on Basic Characteristics of Establishments (사업체 기초통계조사에서 산업활동의 공간집적도 측정 연구)

  • 김윤수;정연수;김병천
    • The Korean Journal of Applied Statistics
    • /
    • v.17 no.1
    • /
    • pp.13-26
    • /
    • 2004
  • According to economic growth theory, location configuration of business enterprises engaged in specific industries has spatial affinity. In this research we defined industrial concentration index to measure industry agglomeration using the characteristics of dispersion parameter of negative binomial distribution, and used the industrial concentration index to examine aspect of spatial configuration change. We utilized Census on Basic Characteristics of Establishments of 1995 and 2000 to deduce industrral concentration indices of 7 knowledge-based industries and 9 strategy-based industries of Choongbuk Province and analyzed the aspect of spatial configuration change.

Soot Concentration and Temperature Measurements in Laminar Ethylene Jet Double-concentric Diffusion Flames (동축 이중 에틸렌 확산화염의 매연 농도분포 및 온도 측정)

  • Lee, Gyo-U;Jeong, Jong-Su;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.402-409
    • /
    • 2002
  • Experiments were performed with double-concentric diffusion flame(DDF) in order to investigate the characteristics of soot formation and temperature distributions. The flame size and shape of the DDF are similar to those of the well-known normal co-flow diffusion flame(WF), except the formation of a tiny inverse flame near the central tube exit. A laser light extinction technique was used to measure the soot volume fractions. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple. Soot concentrations along the flame axis of the DDF were higher than those of the NDF. However, the maximum soot volume fraction of the DDF along the periphery of the flame was lower than that of the NDF. It is mainly due to the effect of nitrogen-dilution from the inner air. Measured temperature distribution explains these trends of soot concentration. The temperature along the flame axis was also higher in DDF than that of the NDF. However, the flame temperatures at the flame front of the two flames were almost same regardless of the inner flame. This phenomenon means that the inverse flame inside the DDF did not affect on the flame structure including the temperature and soot concentration, except the region around the flame axis.

Measurement of Soot and Temperature on Bio Diesel Flame by Two-Color Method (이색법에 의한 바이오 디젤화염의 그을음과 온도 측정)

  • Kim, M.S.;Kang, H.Y.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.5-11
    • /
    • 2012
  • There were some papers for diesel engine performance tests using BDF, but few article deals with the temperature and soot concentration of Bio diesel flame. Since the flame temperature of diesel engines is so high and change rapidly, an optical method for measurement of flame temperature is known as the most effective one. The two-color method regarding the visible wavelength radiation for the soot particles in flame was applied on Bio diesel flame in order to measure flame temperature and soot concentration in a diesel engine. Photo detecting device was newly designed and employed TSL250R, photo-diode, to pick-up the light information emitted from the combustion flame. As a result, real flame temperature T, as a flame brightness temperature, through Ta1, Ta2, were obtained and finally the characteristics of KL value as a soot concentration reveal the difference of combustion information between diesel fuel, blending oil and Bio diesel fuel oil.

A Study on BTEX Concentration of Soil's Network in Seoul (서울의 토양측정망중 BTEX 농도 조사에 관한 연구)

  • 김광래;이재영;박찬구;엄석원
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.45-53
    • /
    • 1999
  • The soil samples were measured at 90 sites of Soil's Network In 1997~1998 which was established for the investigation of soil contamination in Seoul. This study was more focused to measure and analyze for BTEX(Benzene, Toluene, Ethylbenzene and Xylene) concentration in the Soil Network. Also, the samples were analyzed by Purge & Trap method. As a result, the BTEX were detected at all sampling sites in Seoul. The Min. Max and Mean BTEX concentration were respectively 0.047mg/kg, 2.618mg/kg and 0.437mg/kg in 1998. The concentration of the BTEX detected at all sampling sites was lower than that of the intervention standards(at industrial areas) of Soil Preservation Act.

  • PDF

Micro-LIF measurement of microchannel flow

  • Kim Kyung Chun;Yoon Sang Youl
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.65-74
    • /
    • 2004
  • Measurement of concentration distributions of suspended particles in a micro-channel is out of the most crucial necessities in the area of Lab-on-a-chip to be used for various bio-chemical applications. One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1\;to\;3\times3\;or\;5\times5$ pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

Experimental Study on Two-Phase Flow Parameters of Subcoolet Boiling in Inclined Annulus

  • Lee, Tae-Ho;Kim, Moon-Oh;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.29-48
    • /
    • 1999
  • Local two-phase flow parameters of subcooled flow boiling in inclined annulus were measured to investigate the effect of inclination on the internal flow structure. Two-conductivity probe technique was applied to measure local gas phasic parameters, including void fraction, vapor bubble frequency, chord length, vapor bubble velocity and interfacial area concentration. Local liquid velocity was measured by Pilot tube. Experiments were conducted for three angles of inclination; 0$^{\circ}$(vertical), 30$^{\circ}$, 60$^{\circ}$. The system pressure was maintained at atmospheric pressure. The range of average void fraction was up to 10% and the average liquid superficial velocities were less than 1.3 m/sec. The results of experiments showed that the distributions of two-phase How parameters were influenced by the angle of channel inclination. Especially, the void fraction and chord length distributions were strongly affected by the increase of inclination angle, and flow pattern transition to slug flow was observed depending on the How conditions. The profiles of vapor velocity, liquid velocity and interfacial area concentration were found to be affected by the non-symmetric bubble size distribution in inclined channel. Using the measured distributions of local phasic parameters, an analysis for predicting average void fraction was performed based on the drift flux model and flowing volumetric concentration. And it was demonstrated that the average void fraction can be more appropriately presented in terms of flowing volumetric concentration.

  • PDF