• Title/Summary/Keyword: concentration image

Search Result 496, Processing Time 0.028 seconds

An Analysis of Formative Properties for the Hat and the Fashion Image in the Fashion Collection (패션 컬렉션에 나타난 모자와 패션 이미지에 대한 조형성 분석)

  • Kang, Kyung-Ja;Jeong, Hae-Sun
    • The Research Journal of the Costume Culture
    • /
    • v.14 no.1
    • /
    • pp.64-78
    • /
    • 2006
  • The purpose of this study is to set a characteristic design by analyzing formative properties for the hat and fashion image shown in fashion collections from the S/S season of 1998 to the F/W season of 2004 in recent seven years. For the study, the 96 stimuli which found frequently in fashion collection were selected. The examines for the image evaluation were women college students majoring fashion design related fields and living in Seoul, Gyeonggi-do, and Gyeongsangnam-do. Data collection was performed in August 2004. As statistical methods for data analysis, internal consistency method, Factor Analysis, MANOVA were used. Based on the analysis of 31 pairs of adjectives for elucidating the total 96 stimuli which were devised by altering the types of garment, the relation between a garment and a color of hat, the types of hat, the length of hair, and the material and design of garment, five factors or attractiveness, gracefulness, concentration, cuteness, and hardness and softness were deduced. And it showed much difference in the types of garment, the relations between a garment and a color of hat, the types of hat, the length of hair, and the material and design of a garment.

  • PDF

Zero-Watermarking Algorithm in Transform Domain Based on RGB Channel and Voting Strategy

  • Zheng, Qiumei;Liu, Nan;Cao, Baoqin;Wang, Fenghua;Yang, Yanan
    • Journal of Information Processing Systems
    • /
    • v.16 no.6
    • /
    • pp.1391-1406
    • /
    • 2020
  • A zero-watermarking algorithm in transform domain based on RGB channel and voting strategy is proposed. The registration and identification of ownership have achieved copyright protection for color images. In the ownership registration, discrete wavelet transform (DWT), discrete cosine transform (DCT), and singular value decomposition (SVD) are used comprehensively because they have the characteristics of multi-resolution, energy concentration and stability, which is conducive to improving the robustness of the proposed algorithm. In order to take full advantage of the characteristics of the image, we use three channels of R, G, and B of a color image to construct three master shares, instead of using data from only one channel. Then, in order to improve security, the master share is superimposed with the copyright watermark encrypted by the owner's key to generate an ownership share. When the ownership is authenticated, copyright watermarks are extracted from the three channels of the disputed image. Then using voting decisions, the final copyright information is determined by comparing the extracted three watermarks bit by bit. Experimental results show that the proposed zero watermarking scheme is robust to conventional attacks such as JPEG compression, noise addition, filtering and tampering, and has higher stability in various common color images.

Analysis of Accumulation/Erosion in River Using Satellite Image (인공위성영상을 이용한 하천의 퇴적/침식 분석)

  • Yang In-Tae;Kim Dong-Moon;Chun Ki-Sun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.1
    • /
    • pp.37-45
    • /
    • 2006
  • Damage of rivers construction is serious to natural disaster by concentration rainfall in summer. Specially, increase of soil erosion breeds flood calamity of river bed accumulation and pondage decline etc., and erosion increase in upper stream shows in rivers flood of earth and sand, farm land and form of urban district burying. Flood damage investigation through on-the-spot probe until present need effective and scientific modelling techniques because is not efficient. This research wished to examine practical use of monitoring data of high resolution satellite image through satellite image analysis of various space resolution. Research analyzed abstraction possibility of soil disaster information using high resolution satellite image. Also, studied soil disaster damage present condition interpretation practical use possibility through various resolution satellite image analysis, and studied practical use of KOMPSAT image for interpretation of river topography change analysis.

The role of corporate image and privacy concerns in adopting online travel services

  • Tapanainen, Tommi;Nguyen, Thi Thanh Hai;Dao, Kien Trung
    • The Journal of Information Systems
    • /
    • v.28 no.3
    • /
    • pp.1-23
    • /
    • 2019
  • Purpose This study examines the role of corporate image and privacy concerns in intention to use of online travel services using data from Vietnam. Design/methodology/approach The data collection was implemented to a student sample at the Foreign Trade University in Hanoi, which has a high concentration of young people who are interested in online travel in Vietnam. The paper based questionnaire was directly delivered to the respondents. After sorting to eliminate unfit samples, the number of responses was 541, which exceeds 500, the minimum number typically required. To test the hypotheses, we applied structural equation modeling (SEM) and Confirmatory Factor Analysis (CFA) was used to evaluate the reliability and validity of constructs in the model. We also used direct, indirect and total effect coefficient to evaluate the total impact of factors on the intention to use online services. Findings This study found that corporate image is positively associated to intention to use online services. It found a link between corporate image and privacy concerns, which suggests another way for firms to address their customers' privacy concerns; corporate image, which has received great attention in traditional offline sales channels, but not in online services, should receive higher attention in IS research. Online travel businesses, besides increasing ease of use, perceived usefulness and trust in their services, should focus on build a reliable corporate image, which can not only promote the service use but also help to eliminate users' the privacy concerns.

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.

Study on the Development of the Displacement and Strain Distribution Measurement Algorithm to the Open Hole Tension Test by Using the Digital Image Correlation (이미지 상관법을 이용한 원공 인장 시편 변위 및 변형율 측정을 위한 알고리즘 개발에 관한 연구)

  • Choi, In Young;Kang, Young June;Hong, Kyung Min;Lee, Hak Seong;Kim, Seong Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.2
    • /
    • pp.121-128
    • /
    • 2016
  • The mechanical jointing method is very important in the machine parts and structure. They are used by the bolts and rivet because it is very convenient to replace the parts and the structure. However, the mechanical jointing methods using the bolt and rivet needed the open hole. The machine parts life cycle is reduced because this open hole created the stress concentration. Therefore, the measurement methods are needed to evaluate phenomenon of the stress concentration. This paper discusses the development of the measurement algorithm using the digital image correlation methods to measure the strain distribution of the open hole. To implement the measurement algorithm using the DIC, the LabVIEW 2010 programming tool was used. To measure the strain distribution of the open hole, the tensile specimens having an open hole are made by using the aluminum 6061-T6. To secure the reliability of measurement result using the DIC, the DIC measurement results and FEM analysis results were compared.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

Quantification of nitric oxide concentration in the hemocytes of Manila clam Ruditapes philippinarum by using 4,5-diaminofluorescein diacetate (DAF-2) detection method (바지락 (Ruditapes philippinarum) 혈구의 일산화질소 (nitric oxide) 정량)

  • Nam, Ki-Woong;Yang, Hyun-Sung;Park, Kyung-Il
    • The Korean Journal of Malacology
    • /
    • v.29 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • Nitric oxide (NO) is an important intra-intercellular signaling molecule that regulates many physiological processes and participates in the development some pathological conditions in animals. In this study, we compared different methods for determining NO concentration in the hemocytes of Manila clam Ruditapes philippinarum. For measuring the intracellular NO levels, we used the specific fluorescent probe 4,5-diaminofluorescein diacetate (DAF-2 DA), and the quantification methods that were compared were based on image analysis, spectrophotometry, and flow cytometry. NO concentration could be determined using all the 3 methods, and the concentration varied significantly depending upon the presence of NO regulators in the hemocytes; NO concentration increased in the presence of L-arginine, while it decreased in the presence of N-nitro-L-arginine methyl ester. In particular, it is found that estimation of NO using a flowcytometry is more economical, reliable and accurate compared to image analysis and spectrophotometry. Accordingly we believe that determining NO concentration by using flowcytometry will be useful in evaluating physiological and pathological conditions in marine bivalves.

Thermal distribution change in polyvinyl alcohol gel caused by focused ultrasound (폴리비닐알코올 젤의 집속초음파에 의한 온도분포 변화)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.6
    • /
    • pp.576-584
    • /
    • 2020
  • In order to obtain basic information for using polyvinyl alcohol (PVA) gel as a tissue mimicking phantom for temperature visualization, the temperature change characteristics due to the focused ultrasound were examined for different concentration of PVA. To obtain the basic acoustic characteristics, the speed of sound, the attenuation coefficient, and the density depending on the PVA concentration were measured, and the thermodynamic characteristics, such as thermal conductivity and heat capacity, were measured. The range of temperature rising in the vicinity of the focal point due to the focused ultrasound was observed using a thermochromic film that changes color at 30 degree or more, and the discolored area was obtained by image processing of the recorded image. As the concentration of PVA increases in the given range of 2 wt% ~ 16 wt%, the area that rises above 30 degree inside the gel increases linearly. It is confirmed that the discolored area increases as the power applied to the focused ultrasonic transducer increases. These results showed good agreement with the simulation results using the finite element method.

An Method for Inferring Fine Dust Concentration Using CCTV (CCTV를 이용한 미세먼지 농도 유추 방법)

  • Hong, Sunwon;Lee, Jaesung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1234-1239
    • /
    • 2019
  • This paper proposes a method for measuring fine dust concentration through digital processing of images captured by only existing CCTVs without additional equipment. This image processing algorithm consists of noise reduction, edge sharpening, ROI setting, edge strength calculation, and correction through HSV conversion. This algorithm is implemented using the C ++ OpenCV library. The algorithm was applied to CCTV images captured over a month. The edge strength values calculated for the ROI region are found to be closely related to the fine dust concentration data. To infer the correlation between the two types fo data, a trend line in the form of a power equation is established using MATLAB. The number of data points deviating from the trend line accounts for around 12.5%. Therefore, the overall accuracy is about 87.5%.