• Title/Summary/Keyword: concentration image

Search Result 496, Processing Time 0.027 seconds

Eating Behaviors, Perception of Body Image, Hematological Indices and Nutrient Intake of Adolescent Female Athletes in Incheon (인천지역 청소년 여자 운동선수의 식행동, 체형에 관한 인식 및 영양상태평가)

  • 정선희;성현이;김순기;김광회;조미혜;장경자
    • Korean Journal of Community Nutrition
    • /
    • v.8 no.6
    • /
    • pp.951-963
    • /
    • 2003
  • The purpose of this study was to investigate the eating behaviors, the self-perception of body images, the hematological indices and the nutrient intake of adolescent female athletes in Incheon. The subjects were 112 female athletes(track and fleld: n=32, target shooting: n=27, fencing n=29, swimming: n=14, badminton: n=10) from middle and high schools in Incheon. This cross-sectional study was conducted by means of a sol(-administered questionnaire. Fasting blood samples were obtained and analyzed for hemoglobin (Hb), hematocrit (Hct), ferritin, serum iron, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration(MCHC), unsaturated iron binding capacity (UIBC), total iron binding capacity (TIBC) and transferrin saturation (TS). Nutrient intakes obtained by means of the 3 day-recall method were analyzed using the Computer Aided Nutritional Analysis Program. Statistical analysis was conducted using the SPSS 10.0 program. Most of the female athletes had dietary problems such as eating unbalanced meals, skipping meals, and preferences for processed foods. More than 60% of the female athletes skipped breakfast. As for perception of their body images, track and field athletes in particular, controlled their weights significantly better than the other athletes (p<0.05). With regard to their physical exertion during exercise, 56.3% of the swimmers and 31.3% of the track and field athletes answered “very hard”, which was a significant difference (p< 0.001). More than 80% of the female athletes experienced vertigo during exercise (p< 0.01). Also more than 50% of the female athletes, with the exception of the badminton players, had experienced irregular menstruation (p<0.05). The average serum iron levels (p<0.05), the serum ferritin levels (p<0.05) and TS (p<0.05) of the track and field athletes was significantly lower as compared to that of the other athletes. The nutrient intakes of the female athletes, with the exception of Vitamin B$_{6}$, niacin and phosphorus were lower than the Korean Recommended Daily Allowances (RDA). In particular, the calcium and iron intakes of the female athletes were under 50% of the Korean RDA. Therefore, proper nutritional education and supplementation are required for female athletes to encourage desirable eating habits, as well as to improve their nutritional status and exercise performances.s.

Brightness Value Comparison Between KOMPSAT-2 Images with IKONOS/GEOEYE-1 Images (KOMPSAT-2 영상과 IKONOS/GEOEYE-1 영상의 밝기값 상호비교)

  • Kim, Hye-On;Kim, Tae-Jung;Lee, Hyuk
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.2
    • /
    • pp.181-189
    • /
    • 2012
  • Recently, interest in potential for estimating water quality using high resolution satellite images is increasing. However, low SNR(Signal to Noise Ratio) over inland water and radiometric errors such as non-linearity of brightness value of high resolution satellite images often lead to accuracy degradation in water quality estimation. Therefore radiometric correction should be carried out to estimate water quality for high resolution satellite images. For KOMPSAT-2 images parameters for brightness value-radiance conversion are not available and precise radiometric correction is difficult. To exploit KOMPSAT-2 images for water quality monitoring, it is necessary to investigate non-linearity of brightness value and noise over inland water. In this paper, we performed brightness value comparison between KOMPSAT-2 images and IKONOS/GeoEye-1, which are known to show the linearity. We used the images obtained over the same area and on the same date for comparison. As a result, we showed that although KOMPSAT-2 images are more noisy;the trend of brightness value and pattern of noise are almost similar to reference images. The results showed that appropriate target area to minimize the impact of noise was $5{\times}5$. Non-linearity of brightness value between KOMPSAT-2 and reference images was not observed. Therefore we could conclude that KOMPSAT-2 may be used for estimation of water quality parameters such as concentration of chlorophyll.

THE REMINERALIZATION ASPECT OF ENAMEL ACCORDING TO CHANGE OF THE DEGREE OF SATURATION OF THE ORGANIC ACID BUFFERING SOLUTION IN pH 5.5 (pH 5.5에서 유기산 완충용액의 포화도 변화에 따른 법랑질의 재광화 양상)

  • Park, Jin-Sung;Park, Sung-Ho;Park, Jeong-Won;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.96-105
    • /
    • 2010
  • The purpose of this study is to observe and compare the remineralization tendencies of artificial enamel caries lesion by remineralization solutions of different degree of saturations at pH 5.5, using a polarizing microscope and computer programs (Photoshop, Image pro plus, Scion Image, Excel). For this study, 48 sound permanent teeth with no signs of demineralization, cracks, or dental restorations were used. The specimens were immersed in lactic acid demineralization solution for 2 days in order to produce artificial dental caries that consist of surface and subsurface lesions. Each of 9 or 10 specimens was immersed in pH 5.5 lactic acid buffering remineralization solution of four different degrees of saturation (0.507, 0.394, 0.301, and 0.251) for 12 days. After the demineralization and remineralization, images were taken by a polarizing microscope (${\times}100$). The results were obtained by observing images of the specimens, and using computer programs, the density of caries lesions were est mated. While the group with the lowest degree of saturation (0.251) showed total remineralization feature from the surface to the subsurface of the lesion, the group with the highest degree of saturation (0.507) showed demineralization mainly on the surface of the lesion at the constant organic acid concentration 0.01 M and pH 5.5.

Salt Tolerance Assessment with NaCl of Stauntonia hexaphylla (Thunb.) Decene. and Raphiolepis indica var. umbellata (Thunb.) Ohashi (NaCl 처리에 따른 멀꿀과 다정큼나무의 내염성 평가)

  • Choi, Su Min;Shin, Hyeon Cheol;Kim, Inhea;Huh, Keun Young;Kim, Daeil
    • Horticultural Science & Technology
    • /
    • v.31 no.5
    • /
    • pp.617-625
    • /
    • 2013
  • Stauntonia hexaphylla and Raphiolepis indica, cold-tolerant broadleaved evergreens ranging through the southern region of South Korea, were assessed on salt tolerance with NaCl treatment using visual damage, chlorophyll florescence image, and malondialdehyde (MDA) analysis. As NaCl concentrations increased, the soil pH decreased and EC increased, and the soil of S. hexaphylla was affected more strongly by the treatment than that of R. indica. In visual damage, S. hexaphylla withered above 200 mM NaCl at 20 days after the treatment. All individuals of R. indica survived during the experiment though the leaves of R. indica showed visual damages up to 400 mM NaCl. The color changes in chlorophyll fluorescence showed a strong correlation with the degree of visual damage. As NaCl increased, the red color of the leaves of S. hexaphylla was distinctly changed to blue and chlorophyll fluorescence decreased starting from the margin to the middle of a leaf. R. indica showed subtle color changes and remained in red color during the experiment. At five days after the NaCl treatment, the MDA of S. hexaphylla was above $4.56nmol{\cdot}g^{-1}$ when plants showed the highest visual damage and EC. The MDA of R. indica in all treatments showed below $1.5nmol{\cdot}g^{-1}$ except 400 mM NaCl treatment during the experiment.

Simulation Study of a Large Area CMOS Image Sensor for X-ray DR Detector with Separate ROICs (센서-회로 분리형 엑스선 DR 검출기를 위한 대면적 CMOS 영상센서 모사 연구)

  • Kim, Myung Soo;Kim, Hyoungtak;Kang, Dong-uk;Yoo, Hyun Jun;Cho, Minsik;Lee, Dae Hee;Bae, Jun Hyung;Kim, Jongyul;Kim, Hyunduk;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.31-40
    • /
    • 2012
  • There are two methods to fabricate the readout electronic to a large-area CMOS image sensor (LACIS). One is to design and manufacture the sensor part and signal processing electronics in a single chip and the other is to integrate both parts with bump bonding or wire bonding after manufacturing both parts separately. The latter method has an advantage of the high yield because the optimized and specialized fabrication process can be chosen in designing and manufacturing each part. In this paper, LACIS chip, that is optimized design for the latter method of fabrication, is presented. The LACIS chip consists of a 3-TR pixel photodiode array, row driver (or called as a gate driver) circuit, and bonding pads to the external readout ICs. Among 4 types of the photodiode structure available in a standard CMOS process, $N_{photo}/P_{epi}$ type photodiode showed the highest quantum efficiency in the simulation study, though it requires one additional mask to control the doping concentration of $N_{photo}$ layer. The optimized channel widths and lengths of 3 pixel transistors are also determined by simulation. The select transistor is not significantly affected by channel length and width. But source follower transistor is strongly influenced by length and width. In row driver, to reduce signal time delay by high capacitance at output node, three stage inverter drivers are used. And channel width of the inverter driver increases gradually in each step. The sensor has very long metal wire that is about 170 mm. The repeater consisted of inverters is applied proper amount of pixel rows. It can help to reduce the long metal-line delay.

An Investigation of Emission of Particulate Matters and Ammonia in Comparison with Animal Activity in Swine Barns (양돈사 내 동물 활동도에 따른 암모니아 및 미세먼지 배출농도 특성 분석)

  • Park, Jinseon;Jeong, Hanna;Lee, Se Yeon;Choi, Lak Yeong;Hong, Se-woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.6
    • /
    • pp.117-129
    • /
    • 2021
  • The movement of animals is one of the primary factors that influence the variation of livestock emissions. This study evaluated the relationship between animal activity and three major emissions, PM10, PM2.5, and ammonia gas, in weaning, growing, and fattening pig houses through continuous monitoring of the animal activity. The movement score of animals was quantified by the developed image analysis algorithm using 10-second video clips taken in the pig houses. The calculated movement scores were validated by comparison with six activity levels graded by an expert group. A comparison between PMs measurement and the movement scores demonstrated that an increase of the PMs concentrations was obviously followed by increased movement scores, for example, when feeding started. The PM10 concentrations were more affected by the animal activity compared to the PM2.5 concentrations, which were related to the inflow of external PM2.5 due to ventilation. The PM10 concentrations in the fattening house were 1.3 times higher than those in the weaning house because of the size of pigs while weaning pigs were more active and moved frequently compared to fattening pigs showing 2.45 times higher movement scores. The results also indicated that indoor ammonia concentration was not significantly influenced by animal activity. This study is significant in the sense that it could provide realistic emission factors of pig farms considering animal's daily activity levels if further monitoring is carried out continuously.

Application of DINEOF to Reconstruct the Missing Data from GOCI Chlorophyll-a (GOCI Chlorophyll-a 결측 자료의 복원을 위한 DINEOF 방법 적용)

  • Hwang, Do-Hyun;Jung, Hahn Chul;Ahn, Jae-Hyun;Choi, Jong-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1507-1515
    • /
    • 2021
  • If chlorophyll-a is estimated through ocean color remote sensing, it is able to understand the global distribution of phytoplankton and primary production. However, there are missing data in the ocean color observed from the satellites due to the clouds or weather conditions. In thisstudy, the missing data of the GOCI (Geostationary Ocean Color Imager) chlorophyll-a product wasreconstructed by using DINEOF (Data INterpolation Empirical Orthogonal Functions). DINEOF reconstructs the missing data based on spatio-temporal data, and the accuracy was cross-verified by removing a part of the GOCI chlorophyll-a image and comparing it with the reconstructed image. In the study area, the optimal EOF (Empirical Orthogonal Functions) mode for DINEOF wasin 10-13. The temporal and spatialreconstructed data reflected the increasing chlorophyll-a concentration in the afternoon, and the noise of outliers was filtered. Therefore, it is expected that DINEOF is useful to reconstruct the missing images, also it is considered that it is able to use as basic data for monitoring the ocean environment.

Acute Cytotoxicity Testing of Polyhexamethylene-biguanide (PHMG) and Epigallocatechin-gallate (EGCG) Mixture on the Cultured Human Corneal Epithelial Cell (보존제 PHMB(polyhexamethylene biguanide)-EGCG(epigallocatechin gallate) 혼합물의 각막상피세포 급성독성 평가)

  • Kim, Nam-youl;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.531-541
    • /
    • 2018
  • Purpose : To evaluate the acute cytotoxic effect of polyhexamethylene biguanide (PHMB), epigallocatechin gallate (EGCG) and PHMB/EGCG mixture on the cultured human corneal epithelial cell (HCEpiC). Methods : HCEpiCs were cultured in the media of HCEpiC containing 0.00001~0.005% PHMB, 0.001~5% EGCG and 0.00005% PHMB/0.05% EGCG mixture respectively for 30, 60, 120 and 240 min. Cultured HCEpiCs were fixed and stained with Draq5 and cell viability and apoptosis were evaluated using confocal microscope and ImageXpress $Ultra^{TM}$. Results : Cultured HCEpiC did not show cytotoxic effect at below 0.00005% PHMB and below 0.05% EGCG concentration. In the media containing 0.00005% PHMB/0.05% EGCG, acute cytototoxic effect was not found, whereas damaged HCEpiCS were increased and survival cells were decreased in the media incubated for 240 min. Conclusion : The mixture of 0.00005% PHMB/0.05% EGCG showed non acute cytotoxic effect on the cultured HCEpiCs, however it is needed to investigate its chronic cytotoxic effect.

Development of Collaborative Robot Control Training Medium to Improve Worker Safety and Work Convenience Using Image Processing and Machine Learning-Based Hand Signal Recognition (작업자의 안전과 작업 편리성 향상을 위한 영상처리 및 기계학습 기반 수신호 인식 협동로봇 제어 교육 매체 개발)

  • Jin-heork Jung;Hun Jeong;Gyeong-geun Park;Gi-ju Lee;Hee-seok Park;Chae-hun An
    • Journal of Practical Engineering Education
    • /
    • v.14 no.3
    • /
    • pp.543-553
    • /
    • 2022
  • A collaborative robot(Cobot) is one of the production systems presented in the 4th industrial revolution and are systems that can maximize efficiency by combining the exquisite hand skills of workers and the ability of simple repetitive tasks of robots. Also, research on the development of an efficient interface method between the worker and the robot is continuously progressing along with the solution to the safety problem arising from the sharing of the workspace. In this study, a method for controlling the robot by recognizing the worker's hand signal was presented to enhance the convenience and concentration of the worker, and the safety of the worker was secured by introducing the concept of a safety zone. Various technologies such as robot control, PLC, image processing, machine learning, and ROS were used to implement this. In addition, the roles and interface methods of the proposed technologies were defined and presented for using educational media. Students can build and adjust the educational media system by linking the introduced various technologies. Therefore, there is an excellent advantage in recognizing the necessity of the technology required in the field and inducing in-depth learning about it. In addition, presenting a problem and then seeking a way to solve it on their own can lead to self-directed learning. Through this, students can learn key technologies of the 4th industrial revolution and improve their ability to solve various problems.

Image Comparative Evaluation by PET/CT Equipment Using Phantom (팬텀을 활용한 PET/CT 장비 별 영상 비교 평가)

  • Moo-Jin Jeong;Jun-Chul Ham;Yong-Hoon Choi;Young-Kag Bahn;Han-Sang Lim;Jae-Sam Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.71-79
    • /
    • 2024
  • Purpose: This study aims to identify SUV, SNR, spatial resolution, and axial uniformity under the same reconstruction conditions and to find out the differences between equipment models. Materials and Methods: The equipment was GE's Discovery 600, 710, IQ, MI(GE Healthcare, USA), and the Phantom used ACR(American College of Radiology) Flangeless Esser Phantom and PET/SPECT Performance Phantom. The PET/SPECT Performance Phantom injected 18F-FDG at a concentration of 3.8 kBq/mL, and the ACR Flangeless Esser Phantom made the conditions for Hot Spot and Background activity for 4 : 1. Image evaluation was compared and evaluated for SUV, SNR, spatial resolution, and axial uniformity with the same reconstruction that added SharpIR of VPHD. Results: The SUVmax showed a difference up to 4.6% with an average of 2.71, 2.35, 1.89, and 1.43 from Hot Spot 1 to 4, and the SUVmean showed a difference up to 4.7% with 2.06, 1.75, 1.49, and 1.27. There was a difference up to 5% between equipment, and there was no significant difference between both SUVmax and SUVmean. SNR showed a difference up to 0.04 with an average of 0.37, 0.26, 0.18, and 0.11. FWHM showed a difference up to 0.27. Lastly, COV of axial uniformity was up to 0.018. Conclusion: SUV showed differences within 5% between equipment and showed no significant difference. This is considered to be used as basic data that can be used for the development and replacement of equipment because it has the advantage of being able to observe with a large number of equipment.