• Title/Summary/Keyword: concentration image

Search Result 496, Processing Time 0.028 seconds

Imaging of Dopamine Release Induced by Pharmacologic and Nonpharmacologic Stimulations (약물 및 비약물 자극에 의한 도파민 유리 영상)

  • Cho, Sang-Soo;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.158-165
    • /
    • 2007
  • Technological advances in molecular imaging made it possible to image synaptic neurotransmitter concentration in living human brain. The dopaminergic system has been most intensively studied because of its importance in neurological as well as psychiatric disorders. This paper provides a brief overview of recent progress in imaging studies of dopamine release induced by pharmacologic and nonpharmacologic stimulations.

Image Sticking Property in the In-Plane Switching Liquid Crystal Display by Residual DC Voltage Measurements

  • Jeon, Yong-Je;Seo, Dae-Shik;Kim, Jae-Hyung;Kim, Hyang-Yul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.142-145
    • /
    • 2001
  • The residual DC phenomena in the in-plane switching(IPS)-liquid crystal display(LCD) by the voltage-transmittance (V-T) and capacitance-voltage (C-V) hysteresis method on rubbed polyimide (PI) surfaces were studied. We found that the residual DC voltage in the IPS-LCD was decreasing with the increasing concentration of cyano LCs. The residual DC voltage of the IPS-LCD can be improved by the high polarity of cyano LCs.

  • PDF

Application of DNA Content and Total Protein Concentration to Predict Blooms Caused by Cochlodinium polykrikoides (Dinophyceae) in Korean Coastal Waters (total DNA 및 단백질 함량변화에 의한 C. polykrikoides 조기적조 예측 응용)

  • Cho, Eun-Seob;Park, Yong-Kyu
    • Journal of Life Science
    • /
    • v.14 no.2
    • /
    • pp.255-262
    • /
    • 2004
  • We applied nuclear DNA content stained with 4'-6'-diamidino-2-phenylindole (DAPI) and total protein concentration to predict the existence of Cochlodinium polykrikoides before huge blooms occurred, based on a short-term survey at sites in the South Sea. Fluctuations in environmental conditions and nutrients (nitrate, nitrite, and phosphate) were of a similar range, regardless of sampling sites or early and middle field observations. However, C. polykrikoides abundance was significantly different depending on the station, with a higher cell density of 34, 62, and 57 cells L$^{-1}$ at Stn C2, C5, and C6, respectively than what was found in early August, 2000. In mid August, 2000, the highest cell density of 547 cells L$^{-1}$ at Stn C3 was observed. The relationship between C. polykrikoides abundance, DAPI-stained DNA content, and total protein concentration was a positive correlation coefficient, in particular a higher positive correlation was exposed to even a smaller abundance of C. polykrikoides. These results suggest that DNA stained by DAPI and total protein concentration could play an important index in easily predicting the presence of C. polykrikoides before blooms.

Dual Electrospinning to Manufacture Hybrid Nanofibrous Scaffold using Polyurethane and Poly(Ethylene Oxide) (Polyurethane과 Poly(Ethylene Oxide)를 이용한 hybrid 나노섬유 지지체의 제작)

  • Shin, Ji-Won;Shin, Ho-Jun;Heo, Su-Jin;Kim, Ji-Hee;Hwang, Young-Mi;Kim, Dong-Hwa;Shin, Jung-Woog
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.224-228
    • /
    • 2006
  • The object of this study is to investigate the potential of dual-electrospun polymer based structure for vascular tissue engineering, especially for the medium or small sue blood vessels. Polyurethane(PU), which is known to be biocompatible in this area, was electrospun with poly(ethylene oxide) (PEO). Concentration of PU was fixed at 20wt%, while that of PEO was set from 15 to 35wt%. Morphological features were observed by SEM image and measurement of porosity and cellular responses were tested before and after extracting PEO from the hybrid scaffolds by immersing the scaffolds into distilled water. The diameter of PEO fibers were ranged from 200nm to 500nm. The lower concentration of PEO tended to show beads. The porosity of the scaffolds after extracting PEO was highly increased with higher concentration of PEO as expected. Also, higher proliferation rate of smooth muscle cells was observed at higher concentration of PEO than at the lower concentration and without PEO. As conclusions, this dual electrospinning technique combined with PU and PEO is expected to overcome the current barrier of cell penetration by providing more space for cells to proliferation.

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

Characteristics of Flames Propagating Through Combustible Particles Concentration in a Vertical Duct (수직 배관 내의 농도변화에 따른 분진폭발 특성)

  • Han, Ou-Sup;Han, In-Soo;Choi, Yi-Rac;Lee, Jung-Suk;Lee, Su-Hee
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.41-46
    • /
    • 2011
  • We investigated experimentally the properties of dust explosion through lycopodium particle clouds in a duct to provide the fundamental knowledge. Propagating dust flames in the vertical duct of 120 cm height and 12 cm square cross-section were observed by digital video camera and flame front is visualized using by PIV(Particle Image Velocimetry) system. As the result, when the same average dust concentration existed in the vertical duct, downward flame propagation was faster than the upward flame propagation, its rate increased with dust concentration in 300g/$m^3$. Post flames were caused by the ignition of unburned particles which flowed into the rear region of flame from passage between flame and duct wall, and they generated regardless of duct condition. Also, it was found that appearance frequency of post flames during dust flame propagations increased with the increase of dust concentration.

Luminescence Characteristic of CNT Element in ZnS:(Cu, Al) Thin Film Fabricated by a Screen Printing Method (스크린 프린팅 방법으로 제작한 ZnS:(Cu, AL) 박막의 CNT 불순물 첨가에 의한 광학적 특성에 관한 연구)

  • Shon, Pong-Kyun;Shin, Jun-Ha;Bea, Jae-Min;Lee, Jae-Bum;Kim, Jong-Su;Lee, Sang-Nam
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.1
    • /
    • pp.23-33
    • /
    • 2011
  • This experimental focus to characterize luminescence properties related to CNT (Carbon Nano Tube) element dispersedly implanted in ZnS-based phosphor thin film panel fabricated by a screen printing method. More specifically FE-SEM measurements, L-V(Luminescence vs. Voltage) and photo luminescence were carried out to determine an optimum value of CNT concentration and film thickness for the thin film structure of CNT-ZnS:(Cu, Al) by the screen printing method. We confirmed that an optimum value of CNT concentration in the ZnS:(Cu, Al) film panel is about 0.75 wt% resulting that the electric conductivity is 1.6 times higher than that of pure CNT sample and showing that the luminescence intensity is increasing until the optimum concentration. Clearly, CNT is presenting in the luminescence process providing a pathway for the creation of hot electron and a channel for the electron-hole recombination but overly inserted CNT may hinder to produce the hot electron for making an avalanching process. In case of the overly doped CNT 1.0 wt% in the ZnS-based phosphor, the luminescence intensity is decreasing although the electric conductivity is exponentially increasing. Based on these results, we realized that hot electron occurred by the external electric field or exciton arose by the external photon source are reduced dramatically over the critical value of CNT concentration because CNT element provide various isolated residues in the composites of ZnS based phosphor rather than pathway or channel for the D-A(Donnor to Acceptor) pair transition or the radiative recombination of electron-hole.

Evaluation of the Low Tube Voltage in the Computed Tomography Scan Technique using a Low Concentration Contrast Agent (저농도 조영제를 사용한 CT검사에서 저관전압 기법에 따른 유용성 평가)

  • Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • The purpose of this study is computed tomography contrast agent at low concentrations and low tube voltage technique to evaluate the usefulness on the phantom image. By varying the degree of mixture by the contrast medium concentration it was inserted in phantom. It was taken by changing the tube voltage and tube current step by step, and to evaluate the dose and the CT value obtained from the phantom image. As a result, low-contrast, low tube voltage(300 mgI/ml, 100 kV) was reduced by an average 21%(CTDIvol; computed tomography dose indexvol) more standard condition(350 mgI/ml, 120 kV). SNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 12.2(26%) 6.2(17%). CNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 11.5(32%), 6.3(26%). Research work on the CT scan is necessary in a variety of studies on the low contrast concentration and low tube voltage techniques for dose reduction and reducing of side effects the contrast agent.

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

Analysis for Concentration Range of Fluorescein Sodium (플루오레신나트륨의 농도 범위 분석)

  • Lee, Da-Ae;Kim, Yong-Jae;Yoon, Ki-Cheol;Kim, Kwang-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.