DOI QR코드

DOI QR Code

Evaluation of the Low Tube Voltage in the Computed Tomography Scan Technique using a Low Concentration Contrast Agent

저농도 조영제를 사용한 CT검사에서 저관전압 기법에 따른 유용성 평가

  • Jung, Kang-Kyo (Department of Radiological Science, Catholic University of DaeGu) ;
  • Cho, Pyong-Kon (Department of Radiological Science, Catholic University of DaeGu)
  • 정강교 (대구가톨릭대학교 방사선학과) ;
  • 조평곤 (대구가톨릭대학교 방사선학과)
  • Received : 2016.02.24
  • Accepted : 2016.03.07
  • Published : 2016.03.31

Abstract

The purpose of this study is computed tomography contrast agent at low concentrations and low tube voltage technique to evaluate the usefulness on the phantom image. By varying the degree of mixture by the contrast medium concentration it was inserted in phantom. It was taken by changing the tube voltage and tube current step by step, and to evaluate the dose and the CT value obtained from the phantom image. As a result, low-contrast, low tube voltage(300 mgI/ml, 100 kV) was reduced by an average 21%(CTDIvol; computed tomography dose indexvol) more standard condition(350 mgI/ml, 120 kV). SNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 12.2(26%) 6.2(17%). CNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 11.5(32%), 6.3(26%). Research work on the CT scan is necessary in a variety of studies on the low contrast concentration and low tube voltage techniques for dose reduction and reducing of side effects the contrast agent.

본 연구는 전산화단층검사(computed tomography; CT)에서 저농도 조영제와 저관전압 기법이 선량과 영상에 미치는 유용성을 팬텀으로 평가하였다. 조영제 농도별로 희석정도를 달리하여 실험팬텀에 삽입 후 관전압과 관전류를 단계적으로 변화하여 촬영하였고, 획득된 팬텀영상을 통해 선량과 HU를 평가하였다. 그 결과 표준조건(350 mgI/ml, 120 kV)보다 저농도 조영제와 저관전압 조건(300 mgI/ml, 100 kV)설정이 체적 선량평가(CTDIvol; computed tomography dose $index_{vol}$)에서 평균 21% 감소하였다. SNR은 저농도 조영제와 저관전압 조건이 팬텀에서 측정한 모든 깊이(center, 4.5cm, 2.25cm)의 조영제와 생리식염수를 1:10, 1:20으로 희석한 실험에서 각각 12.2(26%), 6.2(17%) 증가하였다. CNR은 각각 11.5(32%), 6.3(26%) 증가하였다. CT 검사에서 조영제 부작용 감소를 위한 저농도 조영제의 사용과 피폭선량 감소를 위한 저관전압 사용으로 영상에서 높은 감약계수를 통한 다양한 연구가 필요할 것으로 사료된다.

Keywords

References

  1. Coles DR, Small MA, Negus IS: Computed Tomography Comparison of radiation doses from multislice Computed Tomography coronary and conventional diagnostic angiography. J Am Coll Cadiol, 47, 1840-1845, 2006 https://doi.org/10.1016/j.jacc.2005.11.078
  2. JH Kim, JJ Chung, KH Kim: Reduction of Contrast Volume in Head Angiography by MDCT. Journal of Korean Society of Computed Tomographic. Technology, 10(1), 118-121, 2008
  3. Christiansen C: X-ray contrast media, an overview. Toxicology, 209, 185-187, 2005 https://doi.org/10.1016/j.tox.2004.12.020
  4. Mulkens, TH, Bellinck P, Baeyaert M, et al: Use of an Automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation, Radiology, 237, 213-223, 2005 https://doi.org/10.1148/radiol.2363041220
  5. Yu L, Li H, Fletcher JG, et al: Automatic selection of tube potential for radiation dose reduction in CT: a general strategy. Med Phys, 37(1), 234-243, 2010 https://doi.org/10.1118/1.3264614
  6. Caro JJ, Trindade E, McGregor M: The risks of death and of severe nonfatal reactions with high- vs low-osmolarity contrast media, a meta-analysis. AJR Am J Roentgenol 156, 825-832, 1991 https://doi.org/10.2214/ajr.156.4.1825900
  7. Vogl Tj, Honold E, Wolf M, Mohajeri H, Hammerstingl R: Safety of iobitridol in the general population and at-risk patients. Eur Radiol, 16, 1288-1297 2006 https://doi.org/10.1007/s00330-005-0061-9
  8. Gomi T, Nagamoto M, Hasegawa M, Katoh A, Sugiyama M, Murata N, Kunihiro T, Kohda E: Are there any differences in acute adverse reactions among five low-osmolar non-ionic iodinated contrast media?. Eur Radiol, 20, 1631-1635, 2010 https://doi.org/10.1007/s00330-009-1698-6
  9. From AM, Bartholmai BJ, Williams AW, et al: Mortality associated with nephropathy after radiographic contrast exposure. Mayo Clin Proc,83, 1095-1100, 2008 https://doi.org/10.4065/83.10.1095
  10. Marenzi G, Assanelli E, Marana I, et al: N-acetylcysteine and contrastinduced nephropathy in primary angioplasty. N Engl J Med, 354, 2773-2782, 2006 https://doi.org/10.1056/NEJMoa054209
  11. McCullough PA, Wolyn R, Rocher LL, et al: Acute renal failure after coronary intervention: incidence, risk factors, and relationship to mortality. Am J Med, 103, 368-375, 1997 https://doi.org/10.1016/S0002-9343(97)00150-2
  12. Scanlon PJ, Faxon DP, Audet AM, et al: ACC/AHA guidelines for coronary angiography: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography) developed in collaboration with the Society for Cardiac Angiography and Interventions. J Am Coll Cardiol, 33, 1756-1824, 1999 https://doi.org/10.1016/S0735-1097(99)00126-6
  13. Myung Jin Shin, Young Joo Cho: Management of adverse reaction to iodinated radiocontrast media. J Korea Med Assoc. 55(8), 779-780, 2012 https://doi.org/10.5124/jkma.2012.55.8.779
  14. Le Jemtel TH, Padeletti M, Jelic S: Diagnostic and Therapeutic Challenges in Patients with Coexistent Chronic Obstructive Pulmonary Disease and Chronic heart Failure, J Am Coll Cardiol, 49, 171-182, 2007 https://doi.org/10.1016/j.jacc.2006.08.046
  15. Youngcheol Joo: The Study of Understanding of Waiting and Satisfaction of Examination in CT Appointed Patient: With a Focus Transfer Distance and Time Between Hospital and House, Journal of Korean Society of Computed Tomographic Technology, 11(2), 123-131, 2009
  16. From AM, Bartholmai BJ, Williams AW, et al: Mortality associated with nephropathy after radiographic contrast exposure. Mayo Clin Proc, 83, 1095-1100, 2008 https://doi.org/10.4065/83.10.1095
  17. Marenzi G, Assanelli E, Marana I, et al: N-acetylcysteine and contrast induced nephropathy in primary angioplasty. N Engl J Med, 354, 2773-2782, 2006 https://doi.org/10.1056/NEJMoa054209
  18. McCullough PA, Wolyn R, Rocher LL, et al: Acute renal failure aftercoronary intervention: incidence, risk factors, and relationship to mortality. Am J Med, 103, 368-375, 1997 https://doi.org/10.1016/S0002-9343(97)00150-2
  19. Scanlon PJ, Faxon DP, Audet AM, et al: ACC/AHA guidelines for coronary angiography: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography) developed in collaboration with the Society for Cardiac Angiography and Interventions. J Am Coll Cardiol, 33, 1756-1824, 1999 https://doi.org/10.1016/S0735-1097(99)00126-6
  20. Lubicz B, Levivier M, Francois O, et al: Sixty-four-row multisection CT angiography for detection and evaluation of ruptured intracranial aneurysms: interobserver and intertechnique reproducibility. AJNR Am JNeuroradiol, 28, 1949-1955, 2007 https://doi.org/10.3174/ajnr.A0699
  21. McKinney AM, Palmer CS, Truwit CL, et al: Detection of aneurysms by 64-section multidetector CT angiography in patients acutely suspectedof having an intracranial aneurysm and comparison with digital subtractionand 3D rotational angiography. AJNR Am J Neuroradiol, 29, 594-602, 2008 https://doi.org/10.3174/ajnr.A0848
  22. Francesco Papar o, Isabella Garello et al: CT of the abdomen: Degree and quality of enhancement obtained with two concentrations of the same iodinated contrast medium with fixed iodine delivery rate and total iodine load. European Journal of Radiology, 83, 1995-2000, 2014 https://doi.org/10.1016/j.ejrad.2014.07.010
  23. M.M. Lell, G. Jost, J.G. Korporaal, A.H. Mahnken, T.G. Flohr, M. Uder, H. Pietsch: Optimizing contrast media injection protocols in state-of-the art computed tomographic angiography. Invest, Radiol, 50(3), 161-167, 2015 https://doi.org/10.1097/RLI.0000000000000119
  24. Fleischmann D. CT angiography: Injection and acquisition technique. Radiol Clin N Am, 48, 237-247, 2010 https://doi.org/10.1016/j.rcl.2010.02.002
  25. Whal Lee, MD: MDCT Application of vascular system. The 2nd Seoul national university hospital MDCT symposium, 77-78, 2007
  26. Huda W, Scalzetti EM, Levin G: Technique factors and image quality asfunctions of patient weight at abdominal CT. Radiology, 217, 430-435, 2000 https://doi.org/10.1148/radiology.217.2.r00nv35430
  27. Ertl-Wagner BB, Hoffmann RT, Bruning R, et al: Multiedetector row CT angiography of the brain at various kilovoltage settings. Radiology, 231, 528-535, 2004 https://doi.org/10.1148/radiol.2312030543
  28. Bahner ML, Bengel A, Brix G, et al: Improved vascular opacification incerebral computed tomography angiography with 80 kV. Invest Radiol, 40, 229-234, 2005 https://doi.org/10.1097/01.rli.0000155281.32319.52
  29. Casper Mihl, Madeleine Kok, Joachim E. Wildberger, Sibel Altintas et al: Coronary CT angiography using low concentrated contrast media injected with high flow rates. EJR, 84, 2155-2160, 2015 https://doi.org/10.1016/j.ejrad.2015.06.031
  30. C. Mihl, J.E. Wildberger, T. Jurencak, M.J. Yanniello, E.C. Nijssen, J.F. Kalafut, G.Nalbantov, G. Muhlenbruch, F.F. Behrendt, M. Das. Intravascular enhancement with identical iodine delivery rate using different iodine contrast media in a circulation phantom. Invest, Radiol, 48(11), 813-818, 2013 https://doi.org/10.1097/RLI.0b013e31829979e8