• 제목/요약/키워드: computer-assisted surgery

검색결과 82건 처리시간 0.027초

Maxillary Positioning Device for Intermediate Waferless Orthognathic Surgery

  • Lee, Jung-woo
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권2호
    • /
    • pp.87-89
    • /
    • 2016
  • Le fort 1 osteotomy surgery is one of the most popular surgical methods for the treatment of patients with facial bone deformities. An intermediate wafer splint is used to fix the bone segment to the planned position, but there are many steps that can cause errors. To reduce these errors, we propose a method of using a surgical guide made with virtual surgical simulation.

Clinical problems of computer-guided implant surgery

  • Moon, Seong-Yong;Lee, Kyoung-Rok;Kim, Su-Gwan;Son, Mee-Kyoung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.15.1-15.6
    • /
    • 2016
  • Background: The utilization of a cone-beam computed tomography (CT)-assisted surgical template allows for predictable results because implant placement plans can be performed in the actual surgery. In order to assess the accuracy of the CT-guided surgery, angular errors and shoulder/apex distance errors were evaluated by data fusion from before and after the placement. Methods: Computer-guided implant surgery was performed in five patients with 19 implants. In order to analyze differences of the implant fixture body between preoperative planned implant and postoperative placed implant, angular error and distance errors were evaluated. Results: The mean angular errors between the preoperative planned and postoperative placed implant was $3.84^{\circ}{\pm}1.49^{\circ}$; the mean distance errors between the planned and placed implants were $0.45{\pm}0.48mm$ horizontally and $0.63{\pm}0.51mm$ vertically at the implant neck and $0.70{\pm}0.63mm$ horizontally and $0.64{\pm}0.57mm$ vertically at the implant apex for all 19 implants. Conclusions: It is important to be able to utilize these methods in actual clinical settings by improving the various problems, including the considerations of patient mouth opening limitations, surgical guide preparation, and fixation.

악교정수술 골절단술시 컴퓨터 네비게이션 시스템의 이용: Technical Note (USE OF A COMPUTER NAVIGATION SYSTEM FOR OSTEOTOMIES IN THE ORTHOGNATHIC SURGERY: TECHNICAL NOTE)

  • 김문기;강상훈;최영수;김정인;변인영;박원서;이상휘
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.282-288
    • /
    • 2010
  • Surgery with the computer navigation system can make it possible to identify important anatomical structures which are difficult to be confirmed with the naked eye in the operation, and has extended their applications in various surgical fields. The head and neck surgery especially requires detailed anatomical knowledges and these knowledges have influences on postoperative functions and esthetics of a patient. In the orthognathic surgery, we should take osteotomies in the precise locations of the jawbones and move segments to the intended positions. There are so many important anatomical structures around the osteotomy-sites in the orthognathic surgery that the prevention of damage to these structures to obtain satisfactory results without any complication. There are vessels of the pterygoid plexus posterior to the pterygoid plate in the maxilla and the mandibular nerve enters the mandibluar foramen in the mandibular ramus. These locations should be confirmed perioperatively to avoid any injury to these structures. The navigation-assisted surgery may be helpful for this purpose. We performed navigational orthognathic surgeries with preoperative CT images and obtained satisfactory results. The osteotomy was performed in the proper location and damaging the surrounding important anatomical structures was avoided by keeping the saw away from them with the real-time navigation. It may be required to develop proper devices and protocols for the navigation-assisted orthognathic surgery.

An Image-Guided Robotic Surgery System for Spinal Fusion

  • Chung Goo Bong;Kim Sungmin;Lee Soo Gang;Yi Byung-Ju;Kim Wheekuk;Oh Se Min;Kim Young Soo;So Byung Rok;Park Jong Il;Oh Seong Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.30-41
    • /
    • 2006
  • The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods for spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Some experiments employing the developed robotic surgery system are conducted. The experimental results confirm that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to respiration.

Optical Tracker에서 좌우 적외선 영상의 동시 획득에 관한 연구 (A Synchronized Stereo Image Acquisition on the Optical Tracker)

  • 신동익;허수진
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권6호
    • /
    • pp.527-534
    • /
    • 2001
  • 컴퓨터 보조의 3차원 수술지원시스템(CAS. Computer Assisted Surgery)의 3차원 위치검출을 위한 광학식 추적자(Optical Tracker)에서 수술도구에 장착되는 적외선 LED의 좌우 영상을 CCD 카메라로 획득하는 데 있어서 기존의 2개의 프레임그래버를 이용하는 방법을 개선하여 하나의 그래버로 획득하는 방법을 개발하였다 좌우의 영상은 칼라 프레임그래버의 색차신호로 부가되며 이에 관련된 하드웨어 및 검출 알고리즘을 개발하였다 결과적으로 본 연구에서 개발된 방법은 비용이 절감되며 좌우영상의 추출이 빠른 것이 장점이다

  • PDF

Computer Assisted Surgery(CAS)를 이용한 개방형 근위경골절골술 시 전내측피질골경사각이 경골후방경사각에 미치는 영향 (Effect of Anteromedial Cortex Oblique Angle on Change of Tibial Posterior Slope Angle in High Tibial Osteotomy Using Computer Assisted Surgery (CAS))

  • 이호상;김재정;왕준호;김철웅
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.351-361
    • /
    • 2012
  • 슬관절 내반슬과 외반슬의 부정정렬을 교정하는 방법 중 대표적인 수술법이 근위경골절골술이다. 개방형 쐐기 근위경골절골술(OWHTO)의 경우 근위비골 인접부의 경골외측 비골신경을 손상시킬 우려가 없고, 수술도중 교정각의 개방 정도를 임의대로 조절 변경 가능한 장점으로 최근 선호되고 있다. 그러나 술후 관상면에서의 외반 및 내반 교정은 바르게 이루어지는 반면, 시상면에서는 수술자가 의도하지 않은 경골내측고평부의 후방경사각(PSA) 변화가 발생한다는 문제점이 있다. 저자들은 이와 같은 문제의 극복을 위해 Computer Assisted Surgery를 이용한 근위경골절골술 기법을 자체적으로 개발하였고, 근위경골부의 CT 이미지 3차원 재건과 컴퓨터를 이용한 가상절골술을 수행하였다. 또한 술후에도 후방경사각(PSA)이 변화하지 않는 수술기법에 대해 제시하였다. 본 연구결과는 환자고유의 전내측피질골 경사각(ACOA)과 후방경사각(PSA)의 명확한 관계성에 대해 제시해줄 것이며 환자마다 다른 최적의 후방경사각 결정법에 대해 제시해 줄 것으로 판단된다.

Inferior alveolar nerve block by intraosseous injection with Quicksleeper at the retromolar area in mandibular third molar surgery

  • Sovatdy, Sam;Vorakulpipat, Chakorn;Kiattavorncharoen, Sirichai;Saengsirinavin, Chavengkiat;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제18권6호
    • /
    • pp.339-347
    • /
    • 2018
  • Background: There are many techniques of inferior alveolar nerve block injection (IANBI); one among them is the computer-assisted intraosseous injection (CAIOI). Here we aim to evaluate the effectiveness of CAIOI with $Quicksleeper^{(R)}$ in mandibular third molar surgery. Methods: This study is a clinical, single-blind, randomized, split-mouth, controlled trial including 25 patients (10 males and 15 females, mean age 21 years). The patients underwent surgical removal of bilateral mandibular third molars with two different IANBI techniques. One side was injected using $Quicksleeper^{(R)}$, and the other side was injected using a conventional IANBI. Both techniques used one cartridge (1.7 ml) of 1:100,000 epinephrine 4% articaine. A supplementary injection was used if necessary. All volumes of anesthetic agent used were recorded. Statistical analysis was performed using paired t-test and Wilcoxon test. Results: This research showed that CAIOI has faster onset and shorter duration of action than IANBI (P < 0.05). The pain was similar in both techniques. In the CAIOI group, one-third of the cases could be completed without additional anesthesia. The remaining two-thirds required minimal supplementary volume of anesthesia. The success rates were 68% for CAIOI and 72% for IANBI, respectively. Conclusion: CAIOI is an advantageous anesthetic technique. It can be used as an alternative to conventional IANBI for mandibular third molar surgery.

Computer Assisted Surgery(CAS)를 이용한 개방형 쐐기 근위경골 절골술에서 전내측 경골피질경사각이 후방경골경사각의 변화에 미치는 영향 (The Effect of Anteromedial Tibial Cortex Angle on Change of Posterior Tibial Slope Angle in PTO(Proximal Tibial Osteotomy) using Computer Assisted Surgery(CAS))

  • 이호상;김철웅;배지훈;왕준호;박종웅;오동준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1467-1470
    • /
    • 2008
  • An upper tibial opening wedge osteotomy is an operation to cure a malalignment and a degenerate arthritis. To prevent the postoperative malalignment caused by the upper tibial opening wedge osteotomy, the research to define the relationship between a Hinge Axis Angle and a Posterior Slope Angle is needed. The effect of the relationship between the hinge axis angle and the gap angle on the posterior slope angle is studied. After 3-D Compute Tomography (CT) scanning image is reconstructed, the virtual surgery is performed by the reconstructed 3-D tibia model. It was proved that the relationship between the hinge axis angle and the gap angle were constant and the simple mathematical model could be derived. To verify the suggested mathematical model, it compared with the measured data from the virtual surgery. In conclusion, while the deviation between the data from the virtual surgery and ones of the mathematical model under the gap angle<$10^{\circ}$ was less than 1%.

  • PDF

Reliability and Validity of the Femorotibial Mechanical Axis Angle in Primary Total Knee Arthroplasty: Navigation versus Weight Bearing or Supine Whole Leg Radiographs

  • Kim, Seong Hwan;Park, Yong-Beom;Song, Min-Ku;Lim, Jung-Won;Lee, Han-Jun
    • Knee surgery & related research
    • /
    • 제30권4호
    • /
    • pp.326-333
    • /
    • 2018
  • Purpose: To evaluate the reliability and validity of the femorotibial mechanical axis angle from radiographs in the weight bearing (WB) and supine positions compared with navigation-measured values. Materials and Methods: Sixty-eight cases of navigation-assisted total knee arthroplasty (TKA) were included. The pre- and postoperative whole leg radiographs (WLRs) in WB and supine positions were compared with the initial and final navigation values. Results: The mean mechanical axis angle from the preoperative WBWLR and navigation were not statistically different (p=0.079) and were correlated strongly with each other (intraclass correlation [ICC], 0.818). However, on postoperative measurements, although the WBWLR and navigation values were not different (p=0.098), they were not correlated with each other (ICC, 0.093). The standard error of measurement was $1.8^{\circ}{\pm}3.6^{\circ}$ for the preoperative WBWLR and $2.5^{\circ}{\pm}4.8^{\circ}$ for the postoperative WBWLR. The validity that was determined by the Bland-Altman plot was not acceptable for both pre- and postoperative measurements. Conclusions: The preoperative WBWLR could provide accurate but not precise measurement value of the femorotibial mechanical axis angle for navigation-assisted TKA, and postoperative measurements in navigation were not comparable with radiographic measurements. The lack of agreement was found between the radiographic and navigation measurements of the coronal alignment regardless of pre- or postoperative evaluation although the accuracy was found acceptable. Level of Evidence : Level 4.

Bilateral Chylothorax Due to Blunt Spine Hyperextension Injury: A Case Report

  • Lee, Hohyoung;Han, Sung Ho;Lee, Min Koo;Kwon, Oh Sang;Kim, Kyoung Hwan;Kim, Jung Suk;Chon, Soon-Ho;Shinn, Sung Ho
    • Journal of Trauma and Injury
    • /
    • 제32권2호
    • /
    • pp.107-110
    • /
    • 2019
  • Bilateral chylothorax due to blunt trauma is extremely rare. We report a 74-year-old patient that developed delayed bilateral chylothorax after falling off a ladder. The patient had a simple 12th rib fracture and T12 lamina fracture. All other findings seemed normal. He was sent home and on the 5th day visited our emergency center at Halla Hospital with symptoms of dyspnea and lower back pain. Computer tomography of his chest presented massive fluid collection in his right pleural cavity and moderate amounts in his left pleural cavity with 12th rib fracture and T11-12 intervertebral space widening with bilateral facet fractures. Chest tubes were placed bilaterally and chylothorax through both chest tubes was discovered. Conservative treatment for 2 weeks failed, and thus, thoracic duct ligation was done by video assisted thoracoscopic surgery. Thoracic duct embolization was not an option. Postoperatively, the patient is now doing well and happy with the results. Early surgical treatment must be considered in the old patient, whom large amounts of chylothorax are present.