• 제목/요약/키워드: computed tomography number

검색결과 349건 처리시간 0.027초

나이에 따른 한국인 정상 이하선의 전산화단층촬영값의 차이 (Age-dependent Difference in the Computed Tomography Numbers of the Normal Parotid Gland of Koreans)

  • 정호걸;이은숙;김기덕;박창서
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.451-458
    • /
    • 1999
  • Purpose : To determine normal CT number range of parotid gland by analyzing the change by age increase and the difference among individuals and between both sexes in CT number of normal parotid gland. Materials & Methods : 134 subjects who took the CT scan between the period of Jan. 1996 and Dec. 1997 at Yonsei University, Dental Hospital were selected. Criteria for selection were that the patients must be within the normal range clinically and radiologically, and the entire parotid gland on the axial view must be shown. Among the axial views. the one showing the greatest parotid gland size was selected and its CT number was recorded. Also. CT numbers from both masseter muscle were recorded as its control. Results : There was statistically significant correlation between CT number of right and left of parotid glands and masseter muscles. With the increase of age. there is a significant decrease in the CT number of parotid gland(p<0.05). There was no statistically significant difference in CT number between sexes except the 7th decade and beyond age group of parotid gland(p>0.05). Conclusion : As age increases, CT number of parotid gland has a tendency to decrease, and there is no significant difference in the CT numbers between left and right parotid gland. Therefore in the CT scan of patients suspected of having a salivary gland disease of the parotid gland. to consider normal range of the age-dependent CT numbers of parotid gland and compare the CT numbers of the right and left parotid gland might be useful in diagnosing the disease.

  • PDF

상층두께와 관심영역의 크기 변화가 CT 번호에 미치는 영향 (Effect of the slice thickness and the size of region of interest on CT number)

  • 이지연;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권2호
    • /
    • pp.85-91
    • /
    • 2001
  • Purpose: To evaluate the effect of the slice thickness and the size of region of interest (ROI) on CT number using quantitative CT phantom Materials and Methods: The phantom containing 150 mg/cc, 75 mg/cc and 0 mg/cc calcium hydroxyapatite was scanned with 1, 3, 5 and 10 mm slice thicknesses by single energy quantitative computed tomography (QCT). CT numbers were measured on center position of the phantom. Shape of ROI was circular and sizes were 1, 3, 5, 11, 16, 21, 26 and 33 mm². ANOVA and Tukey's multiple comparison method were performed for statistical comparison of CT numbers according to different slice thicknesses. Coefficient of variation of CT number measured in each size of ROI was evaluated in same slice thickness. Results : CT numbers had statistically significant difference according to slice thicknesses (p<0.05). As the slice thickness increased, CT number also increased. As the density of phantom became lower and the size of ROI became smaller, the coefficient of variation of CT number increased. When the size of ROI was more than 11 mm² in 1 mm slice thickness, 5 mm² in 3 mm slice thickness and 3 mm² in 5 mm slice thickness, the coefficient of variation became consistent. In 10 mm slice thickness, the size of ROI had little effect on the coefficient of variation. Conclusion: CT number had variation according to the slice thickness and the size of ROI although the object was homogeneous. The slice thickness and the size of ROI are critical factors in precision of the CT number measurements.

  • PDF

Computed tomographic anatomy of hepatic artery in normal beagle dogs

  • Kim, Soochan;Jeong, Seongmok;Lee, Heechun;Lee, Youngwon;Choi, Hojung
    • 대한수의학회지
    • /
    • 제59권2호
    • /
    • pp.55-58
    • /
    • 2019
  • This study was performed to examine the visualization and anatomical variants of the hepatic artery with dual-phase computed tomography (CT) angiography and three-dimensional volume rendering imaging analysis in clinically normal dogs. Seven healthy beagle dogs were enrolled and underwent dual CT angiography. Arterial phase images could be obtained with multi-detector CT angiography using the fixed-scan method in these dogs. Contrast enhancement of the hepatic parenchyma was quite minimal because of the unique blood supply system of the liver. In most dogs, the main hepatic arterial branches were the right lateral branch, left branch, and right medial branch. Although hepatic arterial variation appears to be common in dogs, only one dog in this study had the caudate lobar branch as the first branch of the hepatic artery. Further study on a larger number of dogs with CT images will be needed to identify and classify the pattern of hepatic arterial variations.

심장혈관검사에서 전산화단층검사와 혈관조영검사의 입사표면선량 및 조영제 사용량에 관한 분석 (Analysis on the Entrance Surface Dose and Contrast Medium Dose at Computed Tomography and Angiography in Cardiovascular Examination)

  • 서영현;한재복;최남길;송종남
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.535-541
    • /
    • 2016
  • 심장혈관검사에서 전산화단층검사(cardiac computed tomography; CCTA)와 혈관조영검사(coronary angiography; CAG)의 입사표면선량을 후향적 방법으로 분석하여 선량의 저감화 방안을 알아보고 조영제 사용량을 실제 측정하여 신기능 저하 환자 및 부작용 발생 확률이 높은 환자 등의 검사 선택 결정에 대한 역할을 확인하고자 하였다. 양 검사의 입사표면선량인 전산화단층촬영지수($CTDI_{vol}$)값과 공기 커마(air kerma)값, 그리고 프레임 수에 따른 조영제 사용량 등을 비교 분석하였다. 실험 대상으로는 2014년 5월부터 2016년 5월까지 본원에서 CCTA와 CAG를 시행한 21명(남11, 여10)을 대상으로 하였고 연령대는 48~85세(평균 $65{\pm}10$세)이고, 몸무게는 37.6~83.3 kg(평균 $63{\pm}6kg$)였다. CAG보다 CCTA를 이용한 심장혈관 검사가 선량의 감소를 기대할 수 있고 조영제 사용량에 있어서는 CCTA보다 CAG가 더 적은 양을 사용한다는 것을 알 수 있었다. 특히 CAG에서 프레임 수가 증가함에 따라 조영제 사용량이 늘어나므로 촬영범위에 적합한 프레임 수를 선택하여 검사 할수록 조영제 사용량을 더욱 감소시킬 수 있을 것으로 사료된다.

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

영상진단 수가 변화가 의료공급자 진료행태에 미치는 영향: 전산화단층영상진단 검사건수를 중심으로 (The Impact of Diagnostic Imaging Fee Changes to Medical Provider Behavior: Focused on the Number of Exams of Computed Tomograph)

  • 조수진;김동환;윤은지
    • 보건행정학회지
    • /
    • 제28권2호
    • /
    • pp.138-144
    • /
    • 2018
  • Background: Diagnostic imaging fee had been reduced in May 2011, but it was recovered after 6 months because of strong opposition of medical providers. This study aimed to analyze the behavior of medical providers according to fee changes. Methods: The National Health Insurance claims data between November 2010 and December 2012 were used. The number of exams per computed tomography was analyzed to verify that the fee changes increased or decreased the number of exams. Multivariate regression model were applied. Results: The monthly number of exams increased by 92.5% after fee reduction, so the diagnostic imaging spending were remained before it. But medical provider decreased the number of exams after fee return. After adjusting characteristic of hospitals, fee reduction increased the monthly number of exams by 48.0% in a regression model. Regardless type of hospitals and severity of disease, the monthly number of exams increased during period of fee reduction. The number of exams in large-scaled hospitals (tertiary and general hospital) were increased more than those of small-scaled hospitals. Conclusion: Fee-reduction increased unnecessary diagnostic exams under the fee-for-service system. It is needed to define appropriate exam and change reimbursement system on the basis of guideline.

Accessory infraorbital foramen location using cone-beam computed tomography

  • Daesung An;Kumar K C;Chakorn Vorakulpipat;Supak Ngamsom;Thongnard Kumchai;Sunya Ruangsitt;Teeranut Chaiyasamut;Natthamet Wongsirichat
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권5호
    • /
    • pp.257-264
    • /
    • 2023
  • Background: Accessory infraorbital foramen (AIOF) can change the normal course of emerging branches of the infraorbital nerve and blood vessels exiting the infraorbital foramen (IOF). This study aimed to examine the AIOF, number of foramina, and their position in relation to IOF using cone-beam computed tomography (CBCT). Methods: We performed a retrospective CBCT assessment of hospital records between January 2018 and August 2022. The CBCT of 507 patients were examined to extract information on the prevalence, number, position, linear distance from the IOF, and diameter of AIOF in relation to demographic factors. Descriptive statistics were used to evaluate the prevalence of AIOF. Mean and standard deviation were used to calculate the linear distance and diameter of the AIOF, respectively. The AIOFs, its distribution, and number were compared between sexes and sides using the chi-square test. The independent t-test and Mann-Mann-Whitney test were used to compare the mean difference between the sexes and sides. Statistical significance was set at P < 0.05. Results: In this current study, the prevalence of AIOF was 7.1% (36 of the 507 patients). Additionally, the current study examined the number of foramina using a single foramen on each side and double foramina located bilaterally at a distance from the AIOF to the IOF. The mean AIOF diameter was also studied, and the AIOF position with respect to the IOF on CBCT was superomedial or inferomedial. There were no statistically significant associations between any of the parameters assessed in this study when comparing sex and sides. Conclusions: A greater number of patients with AIOF presented with a single foramen and unilateral occurrence, without a statistically significant difference. The AIOF was most commonly located superomedial to the IOF.

In vitro Estimation of The Hounsfield Units and The Volume and Void of Canine Struvite Stones as Predictors of Fragility in Extracorporeal Shock Wave Lithotripsy

  • Wang, Ji-hwan;Hwang, Tae-sung;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • 한국임상수의학회지
    • /
    • 제34권3호
    • /
    • pp.178-184
    • /
    • 2017
  • The aim of this study was to determine whether Hounsfield units (HUs), volume, and various void parameters can predict stone fragility in extracorporeal shock wave lithotripsy (ESWL). HU, volume, porosity, number of voids/stone volume, and void distribution of 30 struvite stones were estimated using helical computed tomography (CT) and micro-CT. The number of shock waves necessary for full fragmentation was accepted as a measure of the stone fragility in ESWL. The correlations between the number of shock waves and the HU, volume, porosity, and number of voids/stone volume were examined. The number of shock waves of the two groups according to the void distribution was also compared. Stone volume correlated with the number of shock waves. Shell-patterned struvite stones were significantly less susceptible to fragmentation in ESWL than non-shell-patterned struvite stones. Stone volume and void distribution may be predictors of the outcome of ESWL treatment.

3차원 전산화 단층촬영을 이용한 상악 정중 과잉치의 진단 (THE DIAGNOSIS OF IMPACTED MAXILLARY MESIODENS USING 3-DIMENSIONAL COMPUTED TOMOGRAPHY : A CASE REPORT)

  • 홍영우;김성오;손흥규;이종갑
    • 대한소아치과학회지
    • /
    • 제25권3호
    • /
    • pp.549-554
    • /
    • 1998
  • 저자는 매복된 상악 정중 과잉치를 주소로 내원한 환아를 3차원 전산화 단층촬영술을 이용해 매복된 과잉치의 위치를 파악하였으며 다음의 결론을 얻었다. 1. 인접한 영구치에 대한 위해한 영향을 주지 않기 위해 상악 정중 매복 과잉치의 정확한 위치 판별이 요구된다. 2. 3차원 전산화 단층촬영법은 매복 과잉치의 위치판별에 있어서 객관적인 중요한 정보를 제공한다.

  • PDF

Characterization of mandibular molar root and canal morphology using cone beam computed tomography and its variability in Belgian and Chilean population samples

  • Torres, Andres;Jacobs, Reinhilde;Lambrechts, Paul;Brizuela, Claudia;Cabrera, Carolina;Concha, Guillermo;Pedemonte, Maria Eugenia
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.95-101
    • /
    • 2015
  • Purpose: This study used cone-beam computed tomography (CBCT) to characterize mandibular molar root and canal morphology and its variability in Belgian and Chilean population samples. Materials and Methods: We analyzed the CBCT images of 515 mandibular molars (257 from Belgium and 258 from Chile). Molars meeting the inclusion criteria were analyzed to determine (1) the number of roots; (2) the root canal configuration; (3) the presence of a curved canal in the cross-sectional image of the distal root in the mandibular first molar and (4) the presence of a C-shaped canal in the second mandibular molar. A descriptive analysis was performed. The association between national origin and the presence of a curved or C-shaped canal was evaluated using the chi-squared test. Results: The most common configurations in the mesial root of both molars were type V and type III. In the distal root, type I canal configuration was the most common. Curvature in the cross-sectional image was found in 25% of the distal canals of the mandibular first molars in the Belgian population, compared to 11% in the Chilean population. The prevalence of C-shaped canals was 10% or less in both populations. Conclusion: In cases of unclear or complex root and canal morphology in the mandibular molars, CBCT imaging might assist endodontic specialists in making an accurate diagnosis and in treatment planning.