• Title/Summary/Keyword: computed tomography (CT)

Search Result 2,602, Processing Time 0.026 seconds

Obesity Estimation of Abdominal Fat by Using Computed Tomography : Influence of Breathing Motion on The Fat Measurement (전산화단층영상을 이용한 복부 지방 계측법에서 호흡운동이 비만도 측정에 미치는 영향)

  • Seoung, Youl-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • The purpose of this study was to evaluate how much effect to accuracy when measuring abdominal fat by Computed Tomography (CT) under different respiration movements. The study volunteer composed of 66 normal adults ($50.4{\pm}11.2$ years, 33 males, 33 females). We measured their obesity by using Broca index, body mass index (BMI) and CT and have investigated the correlation. The CT scanning for the obesity measurement have done in two ways, one was done in stopping breath after exhaling and the other was holding a breath after inhaling. The results showed no statistically significant difference among the three measuring techniques. And, the error in two ways of inhaling and exhaling was showed 24.2% of volunteers. The two ways of respiration movements made different result in visceral fat area (P = 0.044), subcutaneous fat area (P = 0.636) and abdominal obesity value (P = 0.012). This study demonstrates that the two ways of respiration movements when scanning CT makes change in accuracy in visceral fat area, and in abdominal obesity quantitative measure. Therefore, our study suggests that CT should take twice in two ways while a patient stops breath after exhaling and holds a breath after inhaling when measuring abdominal obesity using CT equipments.

Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis

  • Selvaraj, Abirami;Jain, Ravindra Kumar;Nagi, Ravleen;Balasubramaniam, Arthi
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.133-140
    • /
    • 2022
  • Purpose: The aim of this review was to systematically analyze the available literature on the correlation between the gray values (GVs) of cone-beam computed tomography (CBCT) and the Hounsfield units (HUs) of computed tomography (CT) for assessing bone mineral density. Materials and Methods: A literature search was carried out in PubMed, Cochrane Library, Google Scholar, Scopus, and LILACS for studies published through September 2021. In vitro, in vivo, and animal studies that analyzed the correlations GVs of CBCT and HUs of CT were included in this review. The review was prepared according to the PRISMA checklist for systematic reviews, and the risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. A quantitative analysis was performed using a fixed-effects model. Results: The literature search identified a total of 5,955 studies, of which 14 studies were included for the qualitative analysis and 2 studies for the quantitative analysis. A positive correlation was observed between the GVs of CBCT and HUs of CT. Out of the 14 studies, 100% had low risks of bias for the domains of patient selection, index test, and reference standards, while 95% of studies had a low risk of bias for the domain of flow and timing. The fixed-effects meta-analysis performed for Pearson correlation coefficients between CBCT and CT showed a moderate positive correlation (r=0.669; 95% CI, 0.388 to 0.836; P<0.05). Conclusion: The available evidence showed a positive correlation between the GVs of CBCT and HUs of CT.

Introduction to Qunatification of Damage Parameters for Concrete Using X-ray Computed Tomography (X-ray Computed Tomography를 이용한 콘크리트의 손상파라미터 정량화)

  • 박대효;박재민;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.501-504
    • /
    • 2003
  • The purpose of this work is to introduce some fundamental stereological concepts to quantify damage parameters using X-ray CT(Computed Tomography) in the scope of CDM(Continuum Damage Mechanics). X-ray CT is a completely nondestructive technique for visualizing features in the interior of opaque solid objects, and for obtaining digital information on their 3D geometries and properties. Many researchers have introduced lots of damage parameters to model the mechanical behavior of deteriorated materials. Those damage parameters can be represented in many forms such as specific void or crack surfaces, the spacing between cracks, the specific damaged surface area, the specific damaged surface area tensor, the mean solid path among the damaged surfaces and the mean solid path tensor. Despite of many accomplishments in CDM since there is no the systematic experiment, it have limitations in application. In this situation, X-ray computed tomography is highlited by many researchers and applied in a wide range of materials including rock, bone, ceramic, metal, soft tissue and concrete.

  • PDF

Diagnostic Significance of Computed Tomography in Thyroid Nodules (갑상선 결절에 대한 전산화단층촬영의 진단적 의의)

  • Lee Seung-Ho;Choi Jong-Ouck;Lee Nam-Joon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.9 no.1
    • /
    • pp.10-15
    • /
    • 1993
  • In this study. we studied the efficacy of CT scan in the diagnosis of the thyroid nodules. CT scan was useful in the identification of nodal metastasis. extracapsular spread and intrathoracic extension. and multiple cystic degeneration or calcification on CT scan suggested a high possibility of thyroid malignancy.

  • PDF

Distinction of Internal Tissue of Raw Ginseng Root Using a Computed Tomography Scanner

  • Jung, In-Chan;Jeong, In-Soo;Kim, Cheon-Suk
    • Journal of Ginseng Research
    • /
    • v.36 no.4
    • /
    • pp.469-476
    • /
    • 2012
  • Raw ginseng root of Panax ginseng is graded according to its shape and the quality of its internal tissue. A variety of grades are sold with prices according to grade. If an inferior raw ginseng is purchased, the consumer experience an economic loss. This research was conducted in order to explore the possibility of developing a noninvasive method for investigating raw ginseng's internal tissue. It has been determined that computed tomography (CT) scanner images agreed with actual cross-sections of raw ginseng. CT images were obtained to assess the internal portions of raw ginseng, and CT scans of raw ginseng were thoroughly measured using the Hounsfield unit (HU) system, since it allows for a more detailed analysis compared to nuclear magnetic resonance imaging. HU is a measure of attenuation used for CT images, with each pixel being assigned a value using a scale on which air is defined as -1000, water as 0 and compact bone as +1000. It takes about one second to process are slice and produce an image of the raw ginseng by a one channel CT scanner. An image good enough to discriminate the internal tissues can be obtained in 1/24 seconds with a one-channel CT scanner. Using this method, images of raw ginseng can be obtained and the characteristics of the internal tissues can be observed in a short time.

Use of positron emission tomography-computed tomography to predict axillary metastasis in patients with triple-negative breast cancer

  • Youm, Jung Hyun;Chung, Yoona;Yang, You Jung;Han, Sang Ah;Song, Jeong Yoon
    • Korean Journal of Clinical Oncology
    • /
    • v.14 no.2
    • /
    • pp.135-141
    • /
    • 2018
  • Purpose: Axillary lymph node dissection (ALND) and sentinel lymph node biopsy (SLNB) are important for staging of patients with node-positive breast cancer. However, these can be avoided in select micrometastatic diseases, preventing postoperative complications. The present study evaluated the ability of axillary lymph node maximum standardized uptake value (SUVmax) on positron emission tomography-computed tomography (PET-CT) to predict axillary metastasis of breast cancer. Methods: The records of invasive breast cancer patients who underwent pretreatment (surgery and/or chemotherapy) PET-CT between January 2006 and December 2014 were reviewed. ALNs were preoperatively evaluated by PET-CT. Lymph nodes were dissected by SLNB or ALND. SUVmax was measured in both the axillary lymph node and primary tumor. Student t-test and chi-square test were used to analyze sensitivity and specificity. Receiver operating characteristic (ROC) and area under the ROC curve (AUC) analyses were performed. Results: SUV-tumor (SUV-T) and SUV-lymph node (SUV-LN) were significantly higher in the triple-negative breast cancer (TNBC) group than in other groups (SUV-T: 5.99, P<0.01; SUV-LN: 1.29, P=0.014). The sensitivity (0.881) and accuracy (0.804) for initial ALN staging were higher in fine needle aspiration+PET-CT than in other methods. For PET-CT alone, the subtype with the highest sensitivity (0.870) and negative predictive value (0.917) was TNBC. The AUC for SUV-LN was greatest in TNBC (0.797). Conclusion: The characteristics of SUV-T and SUV-LN differed according to immunohistochemistry subtype. Compared to other subtypes, the true positivity of axillary metastasis on PET-CT was highest in TNBC. These findings could help tailor management for therapeutic and diagnostic purposes.

Computed Tomographic Evaluation of Three Canine Patients with Head Trauma (개에서 컴퓨터단층촬영을 이용한 두부 외상의 평가 3례)

  • Kim, Tae-Hun;Kim, Ju-Hyung;Cho, Hang-Myo;Cheon, Haeng-Bok;Kang, Ji-Houn;Na, Ki-Jeong;Mo, In-Pil;Lee, Young-Won;Choi, Ho-Jung;Kim, Gon-Hyung;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.667-672
    • /
    • 2007
  • This report describes the use of conventional computed tomography(CT) for the diagnosis of head trauma in three canine patients. According to physical and neurologic examinations, survey radiography and computed tomography, these patients were diagnosed as traumatic brain injury. Especially, CT is the imaging modality of first choice for head trauma patients. It provides rapid acquisition of images, superior bone detail, and better visualization of acute hemorrhage than magnetic resonance imaging. It is also less expensive and more readily available. Pre-contrast computed tomography was used to image the head. Then, post-contrast CT was performed using the same technique. The Modified Glasgow Coma Scale(MGCS) score was used to predict their probability of survival rate after head trauma in these dogs. Computed tomogram showed fluid filled tympanic bulla, fracture of the left temporal bone and cerebral parenchymal hemorrhage with post contrast ring enhancement. However, in one case, computed tomographic examination didn't delineate cerebellar parenchymal hemorrhage, which was found at postmortem examination. Treatments for patients placed in intensive care were focused to maintain cerebral perfusion pressure and to normalize intracranial pressure. In these cases, diagnostic computed tomography was a useful procedure. It revealed accurate location of the hemorrhage lesion.

Computed Tomography-Aided Diagnosis of Nasal Adenocarcinoma Treated with Rhinotomy and Radiation Therapy in a Dog (CT 진단 후 비절개술 및 방사선요법으로 치료한 개의 비강 선암의 발생례)

  • 홍성혁;김명철
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.256-259
    • /
    • 2002
  • A 39 kg, 7-year-old male Labrador Retriever dog with a 3-month history of epistaxis, sneezing, and nasal discharge was referred to the Veterinary Medical Center of the Tokyo University. On the plain X-ray and computed tomography (CT) of the head showed increased density of the soft tissue in the left nasal cavity and the tumor infiltrated to nasal septum. The tumor mass removed by rhinotomy. Histopathological examination of the mass revealed adenocarcinoma. Four weeks after the surgery, the radiation therapy was performed twice a week for f weeks. 4 months after surgery, the dog had a recurrence in nasal cavity and administered carboplatin 300 mg/$m^2$ twice. However, the tumor had no response to chemotherapy, additional surgery and additional radiation therapy, and the dog was euthanized at the owner's request. At necropsy, metastatic proliferation was confirmed in the lung, lymph nodes and nasal cavity.

Remnant parietal serosa detection in a cat with true diaphragmatic hernia using computed tomography

  • Lee, Sang-Kwon;Jeong, Wooram;Choi, Jihye
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.2
    • /
    • pp.105-108
    • /
    • 2019
  • A 4-year-old cat was referred for a suspected pulmonary mass. True diaphragmatic hernia presence was diagnosed via computed tomography (CT). There was a thin membrane covering the diaphragmatic defect. The membrane was thinner than the diaphragm. After contrast injection, the membrane was less enhanced than that of the normal diaphragm. The membrane was identified as a remnant of the parietal pleura. In addition, contrast-enhanced CT images provided clarity in viewing the herniated liver and falciform fat. A thinner membrane, covering the diaphragmatic defect, and attached to the thicker normal diaphragm, is considered a unique CT feature of true diaphragmatic hernia.

Measurements of Micro-Defects in the Aluminum Thixoformed Part using Computed Tomography(CT) Technology (CT를 이용한 알루미늄 반응고 성형품의 미세 결함 측정)

  • Lee, S.Y.;Kim, C.H.
    • Transactions of Materials Processing
    • /
    • v.18 no.5
    • /
    • pp.422-427
    • /
    • 2009
  • Computed tomography(CT) has been applied to measure micro-defects in the aluminum knuckle parts manufactured by the thixoforming process. 6061 aluminum alloys were used to form knuckle samples in the semi-solid temperature after the SIMA processing of billets. Tensile specimens were cut from the different locations in a thixoformed knuckle. The size and the distribution of forming defects in tensile specimens were analyzed using CT scanning and image analysis technology before tensile tests. It has been qualitatively shown that the stress-strain curves were significantly affected by the size and the distribution of forming defects although the defect sizes lie in the range of micro-meters.