• Title/Summary/Keyword: compressor algorithm

Search Result 119, Processing Time 0.028 seconds

The Design of Expansible Digital Pulse Compressor Using Digital Signal Processors (DSP를 이용한 확장 가능한 디지털 펄스압축기 설계)

  • 신현익;류영진;김환우
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.93-98
    • /
    • 2003
  • With the improvement of digital signal processors, digital pulse compressor(DPC) is widely used in radar systems. The DPC can be implemented by using FIR filter algorithm in time domain or FFT algorithm in frequency domain. This paper designs an expansible DPC using multiple DSPs. With ADSP-21060 of Analog Devices Inc., the computation time as a function of the number of received range cells and FIR filter tap is compared and analyzed in time domain using C-language and assembly language. therefore, when radar system parameters are determined, the number of DSP's required to implement DPC can be easily estimated.

An efficient Hardware Architecture of Lempel-Ziv Compressor for Real Time Data Compression (실시간 데이터 압축을 위한 Lempel-Ziv 압축기의 효과적인 구조의 제안)

  • 진용선;정정화
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.3
    • /
    • pp.37-44
    • /
    • 2000
  • In this paper, an efficient hardware architecture of Lempel-Ziv compressor for real time data compression is proposed. The accumulated shift operations in the Lempel-Ziv algorithm are the major problem, because many shift operations are needed to prepare a dictionary buffer and matching symbols. A new efficient architecture for the fast processing of Lempel-Ziv algorithm is presented in this paper. In this architecture, the optimization technique for dictionary size, a new comparing method of multi symbol and a rotational FIFO structure are used to control shift operations easily. For the functional verification, this architecture was modeled by C programming language, and its operation was verified by running on commercial DSP processor. Also, the design of overall architecture in VHDL was synthesized on commercial FPGA chip. The result of critical path analysis shows that this architecture runs well at the input bit rate of 256kbps with 33MHz clock frequency.

  • PDF

An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier (베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구)

  • Lee, Heung-Ju;Chang, Young-Soo;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.508-516
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. Failure modes in this study include refrigerant leakage, decrease in mass flow rate of the chilled water and cooling water, and sensor error of the cooling water inlet temperature. It is possible to detect and diagnose faults in this study by adopting FDD algorithm using only four parameters(compressor outlet temperature, chilled water inlet temperature, cooling water outlet temperature and compressor power consumption). Refrigerant leakage failure is detected at 20% of refrigerant leakage. When mass flow rate of the chilled and cooling water decrease more than 8% or 12%, FDD algorithm can detect the faults. The deviation of temperature sensor over $0.6^{\circ}C$ can be detected as fault.

The Performance of Capacity Modulation and MIMO Control for System Heat Pump (시스템 히트펌프의 용량조절 및 다변수 제어 특성에 관한 연구)

  • Song, In-Sik;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan;Choi, Jong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.364-369
    • /
    • 2007
  • A system heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the system heat pump has been employed in small and medium-sized buildings. However, the performance data and control algorithm for system heat pump are limited in literature due to complicated system parameters and operating conditions. In the present study, the performance of a system heat pump with two indoor unit is measured by varying indoor loads, EEV opening, and compressor speed. In addition, the integral optimum regulator which includes MIMO control algorithm is proposed. The capacity modulation and optimum capacity for each indoor unit can be adjusted by utilizing the EEVs opening and compressor speed. The proposed scheme shows appropriate control performance at test conditions.

  • PDF

Discharge Evaluation Program Development of Anti-surge Valve for FPSO Fuel Gas Compressor System (FPSO 연료가스 압축 시스템용 부정류 방지 밸브의 유량 평가 프로그램 개발)

  • Park, Hyung-Wook;Lee, Seung-Min;Cho, Jong-Rae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1411-1418
    • /
    • 2011
  • In this study, to avoid surging in the system as a way to ensure the proper discharge requires the design of the valve capacity rating objective is to develop a program. Approximation algorithm for the capacity evaluation is suggested. Loss coefficients obtained by the algorithm is calculated put in the governing equation for the valve flow coefficient and capacity. Calculated values were compared with numerical analysis results for the verifying their validity. The proven formula is created using Excel and it can be easily available the valve design engineers. Creation of analysis models were using a version of Unigraphics NX 4.0, numerical analysis were using a flow analysis commercial program ANSYS CFX 12.0 version. Equations were referenced 'Handbook of Hydraulic Resistance - 3rd Edition'.

Comparison of Algorithm & Turbulence Modelling for Calculation of Compressor Cascade Flows (압축기 익렬 유동해석을 위한 알고리즘과 난류 모델의 비교 연구)

  • 김석훈;이기수;최정열;김귀순;임진식;김유일
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.59-69
    • /
    • 2000
  • A numerical analysis based on two-dimensional, incompressible and compressible Navier-Stokes equations was carried out for double circular arc compressor cascade and the results are compared with available experimental data. The incompressible code based on SIMPLE algorithm adopts pressure weighted method and hybrid scheme for the convective terms. The compressible code with preconditioning method involves a upwind-biased scheme for the convective terms and LU-SGS scheme for temporal integration. Several turbulence models are evaluated by computing the turbulent viscous flows; Baldwin-Lomax, standard $\kappa$ -$\varepsilon$, $\kappa$ -$\varepsilon$ Lam. Bremhorst, standard $\kappa$-$\omega$, $\kappa$ -$\omega$ SST model.

  • PDF

The EEV Control of the Multi-type Air-conditioning System by using a Fuzzy Logic Superheat Temperature Setpoint Reset Algorithm (퍼지로직 과열도 재설정 알고리즘을 사용한 멀티형 냉방시스템의 전자팽창밸브 제어)

  • 한도영;이상원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.382-388
    • /
    • 2003
  • Refrigerant flow rates of the multi-type air-conditioning system can be regulated by electronic expansion valves (EEV). The performance of the multi-type air-conditioning system may be improved by lowering the superheat at the compressor suction side. In this study, a superheat temperature setpoint reset algorithm was developed by using fuzzy logics, and a PI algorithm was applied to control the superheat temperature near setpoints. Experimental results showed energy savings and stable operations at a multi-type air-conditioning system. Therefore, the developed setpoint reset algorithm may be effectively used for the EEV superheat temperature control of the multi-type air-conditioning system.

Fuzzy Defrost Control of the Multi-Type Heat Pump System (퍼지룰을 이용한 멀티형 히트펌프 시스템의 제상 제어)

  • 한도영;김경훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.711-716
    • /
    • 2000
  • A fuzzy defrost control algorithm for the multi-type heat pump system was developed. In the fuzzy defrost control algorithm, the air temperature difference at the outdoor unit and the refrigerant pressure difference at the compressor were used as input variables, and the defrost starting time and the defrost time interval were used as output variables. This fuzzy algorithm was applied to the multi-type heat pump system and tested in the five dynamic environmental chambers. Test results show that the newly developed control algorithm is more effective than the conventional control algorithm in the removal of frost formed at the outdoor unit of the heat pump.

  • PDF

Compressor Cascade Flow Analysis by Using Upwind Flux Difference Splitting Method (풍상차분법을 이용한 압축기 익렬유동 해석)

  • 권창오;송동주;강신형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.653-661
    • /
    • 1994
  • In this paper the CSCM type upwind flux difference splitting Navier-Stokes method has been applied to study the ARL-SL19 supersonic/transonic compressor cascade flow. H-type grid was chosen for its simplicity in applying cyclic tridiagonal matrix algorithm along with conventional slip/no-slip boundary conditions. The thin-layer algebraic model of Baldwin-Lomax was employed for the calculation of turbulent flows. The test case inlet Mach No. was 1.612 and inlet/exit pressure ratio($P_2/P_1$) was 2.15. The results were compared with experimental results from current method were compared well in suction surface with the experiments and other computational results; however, not well in pressure surface. It might be due to the complex flowfields such as shock/boundary layer interaction, turbulence, and flow separation, etc. In the future, a proper turbulence modelling and adaptive grid system will be studied to improve the solution quality.

Computation of Compressor Flows Using Parallel Implementation of Preconditioning Method (예조건화 기법의 병렬화를 이용한 압축기 유동해석)

  • Lee Gee-Soo;Choi Jeong-Yeol;Kim Kui-Soon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.155-162
    • /
    • 2000
  • In this paper, preconditioning method is parallelized on fast-ethernet PC cluster. The algorithm is based on scaling the pressure terms in the momemtum equations and preconditioning the conservation equations to circumvent numerical difficulties at low Mach numbers. Parallelization is performed using a domain decomposition technique(DDT) and message passing between sub-domains are taken from the MPI library. The results are shown to have good convergence properties at all Mach number on the circular arc Bump and are capable of reasonable predicting two-dimensional turbulent flows on DCA compressor cascade.

  • PDF