• Title/Summary/Keyword: compression shear tests

검색결과 356건 처리시간 0.025초

Experimental study on the shear failure model for concrete under compression-shear loading

  • Shu, Xiaojuan;Luo, Yili;Zhao, Chao;Dai, Zhicheng;Zhong, Xingu;Zhang, Tianyu
    • Computers and Concrete
    • /
    • 제29권2호
    • /
    • pp.81-92
    • /
    • 2022
  • The influence of normal stress perpendicular to the potential shear plane was always neglected in existing researches, which may lead to a serious deviation of the shear strength of concrete members in practice designs and numerical analyses. In this study, a series of experimental studies are carried out in this paper, which serves to investigate the shear behavior of concrete under compression shear loading. Based on the test results, a three-phase shear failure model for cohesive elements are developed, which is able to take into consideration the influence of normal stress on the shear strength of concrete. To identify the accuracy and applicability of the proposed model, numerical models of a double-noted concrete plate are developed and compared with experimental results. Results show that the proposed constitutive model is able to take into consideration the influence of normal stress on the shear strength of concrete materials, and is effective and accurate for describing the complex fracture of concrete, especially the failure modes under compression shear loadings.

세라믹 분말의 변형거동 해석을 위한 미소역학모델 (A micromechanical model for ceramic powders)

  • 하상렬;박태욱;김기태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.668-673
    • /
    • 2008
  • In this paper, we developed a physically-based micromechanical model for inelastic deformation of ceramic powders. The aggregate response of ceramic particles was modeled using the two-surface yield function which considered the shear-induced dilatancy caused by friction, rolling resistance and cohesion between powder particles and consolidation caused by plastic deformation of powder themselves under high compression. The constitutive equations were implemented into the user-subroutine VUMAT of finite element program ABAQUS/Explicit. The material parameters in the constitutive model were identified by calibrating the model to reproduce data from triaxial compression tests and simple compression tests. The density distribution obtained by using the proposed model was in good quantitative agreement with the experimental results of the triaxial compression and cold isostaic compression as well.

  • PDF

철도 강화노반재료의 정ㆍ동적 특성 분석 (Analysis of Static and Dynamic Characteristics of Reinforced Roadbed Materials)

  • 황선근;신민호;이성혁;이시한;최찬용
    • 한국철도학회논문집
    • /
    • 제3권1호
    • /
    • pp.34-41
    • /
    • 2000
  • The analysis of static and dynamic characteristics of reinforced roadbed materials was performed through model and laboratory tests. The strength characteristic of reinforced roadbed materials such as HMS-25 and soil were investigated through the unconfined axial compression test, the model soil box test and the combined resonant column and torsional shear test. The unconfined axial compression strength of HMS-25 shows a steady increasement in strength due to the chemical hardening reaction between HMS-25 and water. The result of model soil box test reveals that railroad roadbed of HMS-25 is better than that of soil in several aspects, such as, bearing capacity and settlement. The combined resonant column and torsional shear test result indicates that shear modulus of HMS-25 and soil increase with the power of 0.5 to the confining pressure and linear relationship to normalized shear modulus and damping ratio.

  • PDF

Extension of theoretical approaches for the shear strength of reinforced concrete beams with corroded stirrups

  • Pier Paolo Rossi;Nino Spinella
    • Computers and Concrete
    • /
    • 제31권1호
    • /
    • pp.33-52
    • /
    • 2023
  • This paper proposes and validates the extension of two models, previously formulated for the evaluation of the shear strength of reinforced concrete members with un-corroded reinforcements, to the case of beams with corroded stirrups. These extended models are based on the plasticity theory (this model has been proposed in the past by one of the authors) and on the simplified modified compression field theory. The response of these models is compared with that of the compression chord capacity model, which has recently been embedded with modifications that simulate the effects of steel corrosion. These latter modifications are first discussed and then introduced into the other two models. An existing database of slender and non-slender beams tested in laboratory by other researchers is revised and improved. Finally, all the considered models are applied to the selected specimens and a comparison is drawn between the shear strength resulting from the considered models and the shear strength resulting from the laboratory tests. The effects of corrosion on some important parameters of the ultimate shear response of the reinforced concrete beams are also discussed.

삼축압축시험을 통한 모래다짐말뚝 공법과 팩말뚝 공법의 거동특성 비교 (Comparison of the Behavior Characteristics between Sand Compaction Pile and Pack Pile by the Triaxial Compression Tests)

  • 유완규;김병일;이승현
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.4012-4017
    • /
    • 2010
  • 이 연구에서는 팩 말뚝과 모래다짐말뚝의 전단강도 특성을 비교하기 위해 모래-팩-점토 복합토 및 모래-점토 복합토를 인위적으로 치환율($a_s$) 10%, 20%로 재성형하여 구속압력을 변화시켜가며 삼축압축시험(CU Test)을 실시하였다. 시험결과 모래-점토 복합토에 비해 모래-팩-점토 복합토의 강도가 치환율 10% 및 20% 모두에서 훨씬 크게 측정되어 모래다짐말뚝보다 팩말뚝이 큰 지지력을 갖는다는 것을 확인하였다.

Experimental study on shear behavior of I-girder with concrete-filled tubular flange and corrugated web

  • Shao, Y.B.;Wang, Y.M.
    • Steel and Composite Structures
    • /
    • 제22권6호
    • /
    • pp.1465-1486
    • /
    • 2016
  • Conventional plate I-girders are sensitive to local buckling of the web when they are subjected mainly to shear action because the slenderness of the web in out-of-plane direction is much bigger. The local buckling of the web can also cause the distorsion of the plate flange under compression as a thin-walled plate has very low torsional stiffness due to its open section. A new I-girder consisted of corrugated web, a concrete-filled rectangular tubular flange under compression and a plate flange under tension is presented to improve its resistance to local buckling of the web and distorsion of the flat plate flange under compression. Experimental tests on a conventional plate I-girder and a new presented I-girder are conducted to study the failure process and the failure mechanisms of the two specimens. Strain developments at some critical positions, load-lateral displacement curves, and load-deflection curves of the two specimens have all be measured and analyzed. Based on these results, the failure mechanisms of the two kinds of I-girders are discussed.

콘크리트 강도에 따른 강섬유 보강기둥의 성능비교 (Comparison of Steel Fiber Reinforced Column Capacity Using Ordinary and High Strength Concrete)

  • 장극관;이현호;문상덕
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.23-28
    • /
    • 2001
  • Since the steel fiber used in concrete to improve shear and ductility capacity, a number of laboratory tests have been studied to define shear strengthening effect according steel fiber contents in concrete. This study investigates shear strengthening effect of steel fiber in RC columns according to compression strength of concrete. From the structural performance test, following conclusions can be made; the maximum enhancement of shear strengthening effect can be achieved at about 1.0 %~l.5 % of steel fiber contents in comparison with shear capacity ratio, and ductility capacity slightly improved as steel fiber contents increased.

  • PDF

양산지역 점토의 비배수 전단강도 특성 (Characteristics of Undrained Shear Strength of Yangsan Clay)

  • 김길수;임형덕;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 연약지반처리위원회 학술세미나
    • /
    • pp.71-78
    • /
    • 2000
  • SHANSEP method involves the consolidation to stresses in excess of the preconsolidation pressure in order to overcome sample disturbance effect. The concept of SHANSEP is based on an approach to laboratory test which attempts to reproduce the in-situ conditions more closely than is possible in routine tests and evaluates normalized strength parameters for the soil as a function of OCR. But SHANSEP method can be applied only to fairly uniform clay deposits, and is unsuitable for a random deposit. In this study, CK/sub o/U triaxial compression test and incremental loading consolidation test were performed for the application of SHANSEP method on Yangsan clay. During the K/sub o/-consolidation, triaxial specimens were consolidated to stress equal to two times the in-situ vertical effective stress. And for overconsolidated condition, the specimens were swelled to a known vertical effective stress in order to have the desired OCR. With the results of CK/sub o/U triaxial compression test using the block samples, the relationship between c/sub u//σ/sub vc/' and OCR on Yangsan clay was established. For evaluating the undrained shear strength of Yangsan clay with depth, CK/sub o/U triaxial compression test was performed using the piston samples taken from Yangsan site. And also undrained shear strength was analyzed from the in-situ test such as Cone Penetration Test(CPT), Dilatometer Test(DMT), and Field Vane Test(FVT) and was compared with that of CK/sub o/U triaxial compression test.

  • PDF

비균열 인장재하 시험체의 압축장 이론에 기반한 전단전달강도 산정모델 (Estimation Model of Shear Transfer Strength for Uncracked Pull-Off Test Specimens based on Compression Field Theory)

  • 김민중;이기열
    • 대한토목학회논문집
    • /
    • 제41권2호
    • /
    • pp.101-111
    • /
    • 2021
  • 전단마찰 시험체는 재하형태에 따라 압축재하와 인장재하 시험으로 구분된다. 인장재하 시험의 경우에는 외력으로 작용하는 수직방향 인장력에 의하여 전단응력 및 수직방향 인장응력이 유발된다. 이 연구에서는 압축장 이론을 이용하여 인장재하 시험체의 전단전달강도를 평가하였으며, 2축-응력 상태의 콘크리트 최대 압축강도의 변화를 고려하기 위하여 수정압축장이론, 연화트러스모델의 구성방정식을 사용하였다. 타당성 검증을 위하여 과거 연구자들에 의해 수행된 직접전단강도 실험값들과 압축장 이론을 이용하여 구한 값들을 비교한 결과, 비균열 인장재하 시험체의 경우 예측값과 실측치가 대체적으로 잘 일치함을 확인하였다. 또한 콘크리트 스트럿의 유효압축강도를 고려한 전단강도 평가식을 제안하고, 기존 문헌에 수록된 실험결과와 비교함으로써 제안식의 적용 가능성을 검증하였다.

Shear behavior of composite frame inner joints of SRRC column-steel beam subjected to cyclic loading

  • Ma, Hui;Li, Sanzhi;Li, Zhe;Liu, Yunhe;Dong, Jing;Zhang, Peng
    • Steel and Composite Structures
    • /
    • 제27권4호
    • /
    • pp.495-508
    • /
    • 2018
  • In this paper, cyclic loading tests on composite frame inner joints of steel-reinforced recycled concrete (SRRC) column-steel beam were conducted. The main objective of the test was to obtain the shear behavior and analyze the shear strength of the joints. The main design parameters in the test were recycled coarse aggregate (RCA) replacement percentage and axial compression ratio. The failure process, failure modes, hysteresis curves and strain characteristics of the joints were obtained, and the influences of design parameters on the shear strength of the joints have been also analysed in detail. Results show that the failure modes of the joints area are typical shear failure. The shear bearing capacity of the joints maximally decreased by 10.07% with the increase in the RCA replacement percentage, whereas the shear bearing capacity of the joints maximally increased by 16.6% with the increase in the axial compression ratio. A specific strain analysis suggests that the shear bearing capacity of the joints was mainly provided by the three shear elements of the recycled aggregate concrete (RAC) diagonal compression strut, steel webs and stirrups of the joint area. According to the shear mechanism and test results, the calculation formulas of the shear bearing capacity of the three main shear elements were deduced separately. Thus, the calculation model of the shear bearing capacity of the composite joints considering the adverse effects of the RCA replacement percentage was established through a superposition method. The calculated values of shear strength based on the calculation model were in good agreement with the test values. It indicates that the calculation method in this study can reasonably predict the shear bearing capacity of the composite frame inner joints of SRRC column-steel beam.