• Title/Summary/Keyword: compound metal

Search Result 534, Processing Time 0.029 seconds

Optimum dimensionally stable anode with volatilization and electrochemical advanced oxidation for volatile organic compounds treatment (전극의 부반응 기포발생에 따른 휘발특성과 전기화학고도산화능을 동시에 고려한 휘발성 유기화합물 처리용 최적 불용성전극 개발)

  • Cho, Wan-Cheol;Poo, Kyung-Min;Lee, Ji-Eun;Kim, Tae-Nam;Chae, Kyu-Jung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.31-41
    • /
    • 2019
  • Volatile organic compounds(VOCs) are toxic carcinogenic compounds found in wastewater. VOCs require rapid removal because they are easily volatilized during wastewater treatment. Electrochemical advanced oxidation processes(EAOPs) are considered efficient for VOC removal, based on their fast and versatile anodic electrochemical oxidation of pollutants. Many studies have reported the efficiency of removal of various types of pollutants using different anodes, but few studies have examined volatilization of VOCs during EAOPs. This study examined the removal efficiency for VOCs (chloroform, benzene, trichloroethylene and toluene) by oxidization and volatilization under a static stirred, aerated condition and an EAOP to compare the volatility of each compound. The removal efficiency of the optimum anode was determined by comparing the smallest volatilization ratio and the largest oxidization ratio for four different dimensionally stable anodes(DSA): Pt/Ti, $IrO_2/Ti$, $IrO_2/Ti$, and $IrO_2-Ru-Pd/Ti$. EAOP was operated under same current density ($25mA/cm^2$) and electrolyte concentration (0.05 M, as NaCl). The high volatility of the VOCs resulted in removal of more than 90% within 30 min under aerated conditions. For EAOP, the $IrO_2-Ru/Ti$ anode exhibited the highest VOC removal efficiency, at over 98% in 1 h, and the lowest VOC volatilization (less than 5%). Chloroform was the most recalcitrant VOC due to its high volatility and chemical stability, but it was oxidized 99.2% by $IrO_2-Ru/Ti$, 90.2% by $IrO_2-Ru-Pd/Ti$, 78% by $IrO_2/Ti$, and 75.4% by Pt/Ti anodes The oxidation and volatilization ratios of the VOCs indicate that the $IrO_2-Ru/Ti$ anode has superior electrochemical properties for VOC treatment due to its rapid oxidation process and its prevention of bubbling and volatilization of VOCs.

A Study on the Luminescence Properties of Eu3+ Ions Doped Vanadate (Eu3+ 이온이 첨가된 바나듐산염의 형광특성 연구)

  • Kang, Yeonhee;Yoon, Changyong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.445-451
    • /
    • 2019
  • The fluorescence intensity and fluorescence lifetime of $Ba_2GdV_3O_{11}$, a vanadate compound based on $Ba^{2+}$ ion, were investigated by adding $Eu^{3+}$ as a rare earth ion which is an alkaline earth metal, which is distributed around active ions and has a large influence on fluorescent properties when used as a host in a phosphor. $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor was synthesized by solid state method and the crystallinity of the phosphor was confirmed by X - ray diffraction analysis. The fluorescence properties of the $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor were measured using optical and laser. The energy transfer and diffusion of the $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor are highly dependent on the concentration of $Eu^{3+}$. When the concentration of $Eu^{3+}$ is low, it shows strong fluorescence to the CT band. However, as the concentration of $Eu^{3+}$ increases, the fluorescence due to 4f - 4f transition is strong. The concentration of $Eu^{3+}$ ion increased and the energy between ions was diffused, and the lifetime of fluorescence decreased. Energy transfer occurs between two $Eu^{3+}$ ions at low $Eu^{3+}$ concentration and energy diffusion occurs at high $Eu^{3+}$ concentration.

Proposals to Revise the Occupational Exposure Limits for Aluminum in Korea (국내 크롬 및 그 화합물의 노출실태 및 노출기준 개정 제안)

  • Seung Won Kim;Young Gyu Phee;Yong-Joon Baek;Taejin Chung;Jeong-Hee Han
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.2
    • /
    • pp.166-178
    • /
    • 2024
  • Objectives: The 12 occupational exposure limits(OELs) for chromium and its compounds in Korea were set by applying the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLVs). However, this is significantly different from the TLVs after the existing TLVs were integrated and withdrawn in 2018, so it is necessary to review the revision. Methods: Various documents related to chromium OELs were reviewed, including the ACGIH TLV Documentations for chromium and its compounds. A field survey was conducted targeting workplaces handling chromium and its compounds. Based on this, a revised OELs were proposed and a socio-economic evaluation was conducted. Results: The OELs for chromium compounds in Korea was first enacted in 2002, and in 2007, the OELs for chromium (hexavalent) compounds (insoluble) was lowered from 0.05 mg/m3 to 0.01 mg/m3. In 2008, the OELs for strontium chromate was newly established as 0.0005 mg/m3, and in 2018, the OELs for calcium chromate was newly established as 0.001 mg/m3. Total chromium and hexavalent chromium were measured for each of 6 samples at 2 welding sites, 4 plating sites, and 2 spray coating sites. When omparing the average of the results measured by ICP, a total chromium analysis method, and the analysis results by IC, a hexavalent chromium analysis method, only workplace 4 was the same, and total chromium was evaluated more, and total chromium was evaluated at 0.0004 to 0.0027 mg/m3. And hexavalent chromium was evaluated as non-detection ~ 0.0014 mg/m3. Amendment ①: The exposure standard for hexavalent chromium is not divided into water soluble, insoluble, chromium ore processing, and other hexavalent chromium compounds, and is integrated into 0.01 mg/m3, which is the level of chromium (hexavalent) compound (insoluble)., OELs for chromium (metal) and chromium (trivalent) compounds are integrated into chromium (trivalent) compounds, and the exposure level is maintained. Amendment ②: As in the amendment ①, the OELs are integrated, but the level is lowered to 0.005 mg/m3, which is the OELs of OSHA, and there is a grace period of 4 years. Amendment ③: As in the amendment ①, the OELs are integrated, but the level is lowered to 0.0002 mg/m3, which is the exposure standard of ACGIH, and there is a grace period of 5 years. Conclusions: Amendment ①: The change in the OELs is insignificant, so the cost required is small, and the benefit/cost ratio is greater than 1, so there is no problem in applying the amendment. Amendment ②: In all scenarios except chromium 6(insoluble), the benefit/cost ratio is greater than 1, so it is thought that there will be no major problem in applying the amendment. Amendment ③: Since the benefit/cost ratio is less than 1 in all scenarios, it is thought that the total social benefit that can be obtained when applying the amendment is not large.

A Study on the Recycling Process of Nickel Recovery from Inconel 713C Scrap based on Hydrometallurgy (인코넬 713C 스크랩으로부터 니켈 자원 회수를 위한 습식제련 기반 재활용공정 연구)

  • Min-seuk Kim;Rina Kim;Kyeong-woo Chung;Jong-Gwan Ahn
    • Resources Recycling
    • /
    • v.33 no.4
    • /
    • pp.36-46
    • /
    • 2024
  • We investigated a hydrometallurgical process of nickel recovery from Inconel 713C scrap. The process proceeded with a series of i) comminution of pyrometallurgical treated scrap, ii) sulfuric acid leaching, iii) solvent extraction of unreacted acid, molybdenum, aluminum, and precipitation of chromium, iv) crystallization of nickel sulfate by vacuum evaporation, and v) nickel electrowinning. The nickel-aluminum intermetallic compound, Ni2Al3, was formed by the pyrometallurgical pretreatment readily grounded under 75 ㎛. Sulfuric acid leaching was done for 2 hours in 2 mol/L, 20 g/L solid/liquid ratio, and 80 ℃. It revealed that over 98 % of nickel and aluminum was dissolved, whereas 28 % of molybdenum was. A nickel sulfate solution with 2.34 g/L for the crystallization of nickel sulfate hydrate was prepared via solvent extraction and precipitation. Over 99 % of molybdenum and aluminum and 93 % of chromium was removed. Nickel metal with 99.9 % purity was obtained by electrowinning with the nickel sulfate monohydrate in the cell equipped with anion exchange membranes for catholyte pH control. The membrane did not work well, resulting in a low current efficiency of 73.3 %.

Other Processed Products, Monitoring and the Exposed Dose Assessment of Heavy Metal, the Illegal Compounds (기타가공품의 중금속, 부정유해물질 모니터링 및 노출량 평가)

  • Jang, Jin-Seob;Kwon, Mun-Ju;Kim, Meyong-Hee;Park, Jin-Soo;Lim, Soo-Sun;Kwon, Sung-Hee;Song, Sung-Min;Yeo, Eun-Young;Hong, Seong-Hee;Kim, Jung-Im;Om, Ae-Son
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.1
    • /
    • pp.35-42
    • /
    • 2015
  • This study was performed for both evaluating the safety of other processed products and providing basic information for making the general standard for contaminants in the category of other processed products. We analyzed the contents of three heavy metals, thirty six anti-impotence drugs and their analogues, three anti-obesity drugs and their analogues, twenty eight steroid drugs and their analogues, collecting in Incheon Metropolitan City. Any illegal compound was not detected in those products. However the contents of lead, cadmium and mercury of those products were at the range of 0.001-13.390 mg/kg, 0.03-1.231 mg/kg and 0.001-0.650 mg/kg respectively. Because there are no standards of heavy metals against other processed products, we compared the analytical results with relevant standards of both S. Korea and foreign countries. As a result, two products exceeded the relevant standards of lead, and other two products exceeded the relevant standards of mercury. The relative hazards compared to PTWI of FAO/WHO (Codex), Seafoods-pajeonmix, Perilla seed powder exceeded PTWI standards 0.214. The compulsory standards of each food product are determined by the category of the products. Because there is no standard of heavy metals in the category of other processed products in S. Korea, any food products registered as other processed product by manufacturer are free with those standards. Abusing similar problems on the categorization of food products could cause consumers' health problem. To prevent these problems, detail regulations on the categorization of food products have to be introduced.

Development of Value-Added Products Using Seaweeds (해조류 가공식품 및 부산물을 이용한 제품 개발)

  • Park, Yang-Kyun;Kang, Seong-Gook;Jung, Soon-Teck;Kim, Dong-Han;Kim, Seon-Jae;Pak, Jae-In;Kim, Chang-Hyeug;Rhim, Jong-Whan;Kim, Jung-Mook
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.2 no.3
    • /
    • pp.133-141
    • /
    • 2007
  • There are produced more than 600,000 tons of seaweeds every year along the coast of the Korea. Jeonnam province, south-west coast area, of Korea is producing 93% of total amounts of seaweeds. The laver, sea mustard, and tangleweed maintain stability in the output and has been exported as a simple product processing through drying or salting. It was evaluated the low value-added products and limited the expansion for the consumption of seaweeds. The seaweeds contains 40-60% carbohydrate and structurally different compared with land plant. The dietary fiber from seaweeds has been known the function of facilitating the bowl movement, excretion the heavy metal in the body, lowering the blood cholesterol level, anti-coagulant of blood, and anticancer. Especially, brown algae including sea mustard, seaweed fusiforme, and tangleweed contains alginic acid, laminarin, mannitol, fucoidan which are lowering the blood cholesterol level, lowering blood pressure, and fusion of blood clot. Agar-agar, carrageenan, and porphyran compound in red algae are known to antimutagenicity and anticoagulant function. In spite of potential of seaweed as a main bio-resource, there are lack of research to facilitate the consumption with its functional properties and consumers are unsatisfied with simple processing products. Also, the seaweed by-product dump into the sea and cause pollution of the seawater. Therefore, there are needed the scheme to promote the consumption of seaweeds. The development of value-added products, finding functional properties from seaweeds, development the functional feed for animal using seaweed by-products, and utilization of unused algae for food or other industrial uses will increase fisherman's income as well as serve as an aid for the people health due to its functional properties. Using by-product of seaweed and unexploited seaweed are needed to development of bio-degradable food packaging material and functional feed for animal.

  • PDF

Electrochemical Characteristics of LiNi0.5Mn1.5O4 Spinel as 5 V Class Cathode Material for Lithium Secondary Batteries (5V급 고전압 양극 LiNi0.5Mn1.5O4 Spinel의 제조와 전기화학적 특성에 관한 연구)

  • Jeon, Sang-Hoon;Oh, Si-Hyoung;Lee, Byung-Jo;Cho, Won-Il;Cho, Byung-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.172-176
    • /
    • 2005
  • Recently, many researches on the high-voltage 5 V class cathode material have focused on $LiNi_{0.5}Mn_{1.5}O_4$, where $Mn^{3+}$ in the existing $LiMn_2O_4 (Li[Mn^{3+}][Mn^{4+}]O_4)$ is replaced by $Ni^{2+}(Li[Ni^{2+}]_{0.5}[Mn^{4+}]_{1.5}O_4)$ in order to utilize $Ni^{2+}/Ni^{4+}$ redox reaction in the 5V region. The partial substitution of Mn in $LiMn_2O_4$ for other transition metal element, $LiM_yMn_{1-y}O_4$(M=Cr, Al, Ni, Fe, Co, Cu, Ga etc) is known as a good solution to overcome the problems associated with $LiMn_2O_4$ like the gradual capacity fading. In this study, we synthesized $LiNi_{0.5}Mn_{1.5}O_4$ through a mechanochemical process and investigated its morphological, crystallographic and electrochemical characteristics. The results showed that 4 V peaks had been found in the cyclic volammograms of the synthesized powders due to the existence of $Mn^{3+}$ from the incomplete substitution of $Ni^{2+}$ for $Mn^{3+}$ implying that the mechanochemical activation alone was not good enough to synthesize an exact stoichiometric compound of $LiNi_{0.5}Mn_{1.5}O_4$. The synthetic condition of mechanochemical process, such as type of starting materials, ball-mill and calcination condition was optimized for the best electrochemical performance.

Minimally Invasive Repair of Pectus Excavatum Based on the Nuss Principle: An Evolution of Techniques and Early Results on 322 Patients (Nuss 술식에 기초한 누두흉의 최소 침습 수술: 수술 수기의 개발 및 322예의 조기 성적)

  • Park, Hyun-Joo;Song, Cheol-Min;Her, Keun;Jeon, Cheol-Woo;Chang, Won-Ho;Park, Han-Gyu;Lee, Seock-Yeol;Lee, Cheol-Sae;Youm, Wook;Lee, Kihl-Roh
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.164-174
    • /
    • 2003
  • Background: The Nuss procedure is a recently developed technique for minimally invasive repair of pectus excavatum using a metal bar. Although its technical simplicity and cosmetic advantages are remarkable, applications have been limited to children with standard pectus excavatum. We report a single center experience of the technique that has been evolving in order to correct asymmetric pectus configurations and adult patients. Material and Method: Between August 1999 and June 2002, 322 consecutive patients un-derwent repair by the Nuss technique and its modifications. Among them, 71 (22%) were adults. For the precise correction, morphology of the pectus was classified as symmetric and asymmetric types. Asymmetric type was subdivided into eccentric and unbalanced types. In repair, differently shaped bars were applied to individual types of pectus to achieve symmetric correction. Result: Symmetric type was 57.5% (185/322) and asymmetric type was 42.5% (137/322). Eccentric, unbalanced, and combined types were 71, 47 and 19, respectively, Major modifications were bar shaping and fixation. In asymmetric group, different shapes of asymmetric bars were applied (n=125, 38.8%). For adult patients, double bar or compound bar technique was used (n=51, 15.8%). To prevent bar rotation, multipoint wire fixations to ribs were used. Major postoperative complications were pneumothorax (n=24, 7.5%) and bar displacement (n=11, 3.4%). 42 patients had bar removal 2 years after the initial procedure. Conclusion: The Nuss procedure is safe and effective. Modifications of the techniques in accordance with precise morphological classification enabled the correction of all variety of pectus excavatum including asymmetric types and adult patients.

Research of Diffusion Bonding of Tungsten/Copper and Their Properties under High Heat Flux

  • Li, Jun;Yang, Jianfeng
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.14-14
    • /
    • 2011
  • W (tungsten)-alloys will be the most promising plasma facing armor materials in highly loaded plasma interactive components of the next step fusion reactors due to its high melting point, high sputtering resistance and low deuterium/tritium retention. The bonding technology of tungsten to Cu alloy was one of the key issues. In this paper, W/CuCrZr diffusion bonding has been performed successfully by inserting pure metal interlay. The joint microstructure, interfacial elements migration and phase composition were analyzed by SEM, EDS, XRD, and the joint shear strength and micro-hardness were investigated. The mock-ups were fabricated successfully with diffusion bonding and the cladding technology respectively, and the high heat flux test and thermal fatigue test were carried out under actively cooling condition. When Ni foil was used for the bonding of tungsten to CuCrZr, two reaction layers, Ni4W and Ni(W) layer, appeared between the tungsten and Ni interlayer with the optimized condition. Even though Ni4W is hard and brittle, and the strength of the joint was oppositely increased (217 MPa) due primarily to extremely small thicknesses (2~3 ${\mu}m$). When Ti foil was selected as the interlayer, the Ti foil diffused quickly with Cu and was transformed into liquid phase at $1,000^{\circ}C$. Almost all of the liquid was extruded out of the interface zone under bonding pressure, and an extremely thin residual layer (1~2 ${\mu}m$) of the liquid phase was retained between the tungsten and CuCrZr, which shear strength exceeded 160 MPa. When Ni/Ti/Ni multiple interlayers were used for bonding of tungsten to CuCrZr, a large number of intermetallic compound ($Ni_4W/NiTi_2/NiTi/Ni_3T$) were formed for the interdiffusion among W, Ni and Ti. Therefore, the shear strength of the joint was low and just about 85 MPa. The residual stresses in the clad samples with flat, arc, rectangle and trapezoid interface were estimated by Finite Element Analysis. The simulation results show that the flat clad sample was subjected maximum residual stress at the edge of the interface, which could be cracked at the edge and propagated along the interface. As for the rectangle and trapezoid interface, the residual stresses of the interface were lower than that of the flat interface, and the interface of the arc clad sample have lowest residual stress and all of the residual stress with arc interface were divided into different grooved zones, so the probabilities of cracking and propagation were lower than other interfaces. The residual stresses of the mock-ups under high heat flux of 10 $MW/m^2$ were estimated by Finite Element Analysis. The tungsten of the flat interfaces was subjected to tensile stresses (positive $S_x$), and the CuCrZr was subjected to compressive stresses (negative $S_x$). If the interface have a little microcrack, the tungsten of joint was more liable to propagate than the CuCrZr due to the brittle of the tungsten. However, when the flat interface was substituted by arc interfaces, the periodical residual stresses in the joining region were either released or formed a stress field prohibiting the growth or nucleation of the interfacial cracks. Thermal fatigue tests were performed on the mock-ups of flat and arc interface under the heat flux of 10 $MW/m^2$ with the cooling water velocity of 10 m/s. After thermal cycle experiments, a large number of microcracks appeared at the tungsten substrate due to large radial tensile stress on the flat mock-up. The defects would largely affect the heat transfer capability and the structure reliability of the mock-up. As for the arc mock-up, even though some microcracks were found at the interface of the regions, all microcracks with arc interface were divided into different arc-grooved zones, so the propagation of microcracks is difficult.

  • PDF

Comparison of Electrical Signal Properties about Top Electrode Size on Photoconductor Film (광도전체 필름 상부 전극크기에 따른 전기적 신호 특성 비교)

  • Kang, Sang-Sik;Jung, Bong-Jae;Noh, Si-Cheul;Cho, Chang-Hoon;Yoon, Ju-Sun;Jeon, Sung-Pyo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.93-96
    • /
    • 2011
  • Currently, the development of direct conversion radiation detector using photoconductor materials is progressing in widely. Among of theses photoconductor materials, mercuric iodide compound than amorphous selenium has excellent absorption and sensitivity of high energy radiation. Also, the detection efficiency of signal generated in photoconductor film varies by electric filed and geometric distribution according to top-bottom electrode size. Therefore, in this work, the x-ray detection characteristics are investigated about the size of top electrode in $HgI_2$ photoconductor film. For sample fabrication, to solve the problem that is difficult to make a large area film, we used the spatial paste screen-print method. And the sample thickness is $150{\mu}m$ and an film area size is $3cm{\times}3cm$ on ITO-coated glass substrate. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a magnetron sputtering system and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$. From experimental measurement, the dark current, sensitivity and SNR of the $HgI_2$ film are obtained from I-V test. From the experimental results, it shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high dark current. Therefore, the optimized size of electrode is importance for the development of photoconductor based x-ray imaging detector.