• Title/Summary/Keyword: composite pipe

Search Result 187, Processing Time 0.025 seconds

Hybrid-Biocomposite Material for Corrosion Prevention in Pipeline: a review

  • Suriani, M.J.;Nik, W.B. Wan
    • Corrosion Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.85-89
    • /
    • 2017
  • One of the most challenging issues in the oil and gas industry is corrosion assessment and management in subsea structures or equipment. At present, almost all steel pipelines are sensitive to corrosion in harsh working environments, particularly in salty water and sulphur ingress media. Nowadays, the most commonly practiced solution for a damaged steel pipe is to entirely remove the pipe, to remove only a localized damaged section and then replace it with a new one, or to cover it with a steel patch through welding, respectively. Numerous literatures have shown that fiber-reinforced polymer-based composites can be effectively used for steel pipe repairs. Considerable research has also been carried out on the repair of corroded and gouged pipes incorporated with hybrid natural fiber-reinforced composite wraps. Currently, further research in the field should focus on enhanced use of the lesser and highly explored hybrid-biocomposite material for the development in corrosion prevention. A hybrid-biocomposite material from renewable resource based derivatives is cost-effective, abundantly available, biodegradable, and an environmentally benign alternative for corrosion prevention. The aim of this article is to provide a comprehensive review and to bridge the gap by developing a new hybrid-biocomposite with superhydrophobic surfaces.

Frequency Response Characteristics of Automotive Hydraulic Pipelines (자동차용 유압관로의 주파수 응답 특성)

  • Kim, Do-Tae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.177-182
    • /
    • 2007
  • In this paper, automotive hydraulic pipeline systems are modeled in which a straight blocked pipe, two pipes with sudden expansion or contraction are connected in series and terminated with a chamber. The frequency response characteristics of these composite pipeline systems are investigated experimentally. The theoretical analysis for various pipe configurations is base on transfer matrix method with frequency dependent viscous friction distributed parameter pipeline model. The gain and phase of transfer functions are included for comparison with experimental results. There is close agreement between the results of experimental and theoretical determination of pressure response in automotive hydraulic pipeline systems.

Finite element modeling of tubular truss bearings

  • Kozy, B.;Earls, C.J.
    • Steel and Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.49-70
    • /
    • 2005
  • This paper reports on finite element analysis techniques that may be applied to the study of circular hollow structural sections and related bearing connection geometries. Specifically, a connection detail involving curved steel saddle bearings and a Structural Tee (ST) connected directly to a large-diameter Hollow Structural Section (HSS) truss chord, near its open end, is considered. The modeling is carried out using experimentally verified techniques. It is determined that the primary mechanism of failure involves a flexural collapse of the HSS chord through plastification of the chord wall into a well-defined yield line mechanism; a limit state for which a shell-based finite element model is well-suited to capture. It is also found that classical metal plasticity material models may be somewhat limited in their applicability to steels in fabricated tubular members.

An Experimental Study of Material Characteristics for GFRP Pipes (GFRP 관로의 재료 특성에 관한 실험적 연구)

  • Han, Taek-Hee;Kim, Sung-Nam;Kang, Young-Jong;Yoon, Ki-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.2 s.13
    • /
    • pp.35-45
    • /
    • 2004
  • Recently, the composite material becomes more popular and its usage is kept expanding from aerospace to civil structures such as bridge decks and irrigation and drainage pipes. The major cause for the popularity can be found in its high strength, light, and excellent anticorrosive properties. Nevertheless the methods to accurately predict and analyze its structural behavior are extremely limited. This has been the major reason circumventing more prevalent use of the composite materials in civil structures. This study is a pre-study to develop the analyzing models for accurate prediction of the composite material structures. Thus, various tests were performed for GFRP pipes to estimate material characteristics of GFRP in this study. And stress-strain relation of GFRP was suggested as a bilinear relation.

Bearing capacity of large diameter PHC pile and large diameter composite pile (대구경 PHC말뚝 및 대구경 복합말뚝($\phi$1,000mm) 지지력 산정에 관한 연구)

  • Shin, Yun-Sup;Park, Jae-Hyun;Hwang, Ui-Seong;Cho, Sung-Han;Chung, Moon-Kyung;Lee, Jin-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.351-359
    • /
    • 2010
  • Large PHC piles with a diameter of 1,000mm or larger were recently introduced for the first time in Korea. This paper presents full-scale static and dynamic pile load tests performed on two 1,000mm PHC piles and two composite piles with steel pipe piles of the same diameter in the upper portion, installed by driving and pre-boring. The objectives of the tests include evaluating pile drivability, load-settlement relation, allowable bearing capacity, and the stability of mechanical splicing element for the composite pile(a.k.a. non-welding joint). The performance of the large diameter PHC piles were thought to be satisfactory compared to that of middle sized PHC piles with a long history of successful applications in the domestic and foreign markets.

  • PDF

Shear resistance of stud connectors in high strength concrete

  • Lee, Young Hak;Kim, Min Sook;Kim, Heecheul;Kim, Dae-Jin
    • Structural Engineering and Mechanics
    • /
    • v.52 no.4
    • /
    • pp.647-661
    • /
    • 2014
  • The use of steel-concrete composite members has been significantly increased as they have the advantages of the reduction of cross sectional areas, excellent ductility against earthquake loadings and a longer life span than typical steel frame members. The increased use of composite members requires an intensive study on the shear resistance evaluation of stud connectors in high strength concrete. However, the applicability of currently available standards is limited to composite members with normal and lightweight strength concrete. In this paper, push-out tests were performed on 24 specimens to investigate the structural behavior and shear resistance of stud connectors in high strength concrete. Test parameters include the existence of shear studs, height to diameter ratio of a shear stud, its diameter and concrete cover thickness. A shear resistance equation of stud connectors is proposed through a linear regression analysis based on the test results. Its accuracy is compared with those of existing shear resistance equations for studs in normal and lightweight concrete.

Vibration Analysis of an Cantilever Beam in Partially Liquid-Filled Cylindrical Pipe (부분적으로 유체가 채워진 원통형 관내의 외팔보 진동해석)

  • 권대규;유계형;방두열;이성철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1073-1078
    • /
    • 2003
  • This paper presents the vibration characteristics of a cantilever beam in contact with a fluid using a PZT actuator and PVDF film. dynamic behaviors of a flexible beam-water interaction system are examined. The effect of the liquid level on free vibration of the composite beam in a partially liquid-filled circular cylinder is investigated. The coupled system is subject to an undisturbed boundary condition un the fluid domain. In the vibration analysis of a wetted beam. the decoupled analyses between beam and fluid have been conventionally employed by considering first the composite beam vibration in the all and secondly Performing the correction taking account for surrounding fluid effects. That is, this investigation was to look at how natural frequencies, mode shapes. and damping are affected by liquid level variations. The signals from the sensor according to the applied input voltage are digitalized and filtered in order to obtain the dynamic characteristics of the composite beam in contact with fluid. It was found that the coupled natural frequencies decreased with the fluid level for the identical composite beam due to added mass effect. In case of the free-free boundary condition, the natural frequency gently decreased at fluid water level between 20% and 80% in the first tending mode and we found out the bends of stair shape for added mass effect of the fluid.

  • PDF

Behaviour of soil-steel composite bridge with various cover depths under seismic excitation

  • Maleska, Tomasz;Beben, Damian
    • Steel and Composite Structures
    • /
    • v.42 no.6
    • /
    • pp.747-764
    • /
    • 2022
  • The design codes and calculation methods related to soil-steel composite bridges and culverts only specify the minimum soil cover depth. This value is connected with the bridge span and shell height. In the case of static and dynamic loads (like passing vehicles), such approach seems to be quite reasonable. However, it is important to know how the soil cover depth affects the behaviour of soil-steel composite bridges under seismic excitation. This paper presents the results of a numerical study of soil-steel bridges with different soil cover depths (1.00, 2.00, 2.40, 3.00, 4.00, 5.00, 6.00 and 7.00 m) under seismic excitation. In addition, the same soil cover depths with different boundary conditions of the soil-steel bridge were analysed. The analysed bridge has two closed pipe-arches in its cross section. The load-carrying structure was constructed as two shells assembled from corrugated steel plate sheets, designed with a depth of 0.05 m, pitch of 0.15 m, and plate thickness of 0.003 m. The shell span is 4.40 m, and the shell height is 2.80 m. Numerical analysis was conducted using the DIANA programme based on the finite element method. A nonlinear model with El Centro records and the time history method was used to analyse the problem.

Strength Characteristics of Hollow Prestressed Concrete Filled Steel Tube Piles for Hybrid Composite Piles (복합말뚝용 중공형 콘크리트 충전 강관말뚝의 강도 특성)

  • Paik, Kyu-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.1
    • /
    • pp.37-46
    • /
    • 2018
  • Hollow prestressed concrete filled steel tube (HCFT) piles, which compose hollow PHC piles inside thin wall steel tubes, are developed. In order to investigate the strength characteristics of HCFT piles, flexural and shear tests were conducted on HCFT piles as well as PHC and steel pipe piles with the same diameter. Results of the test program showed that the flexural strength of HCFT piles was 2.88 and 1.19 times those of ICP and steel pipe piles with thickness of 12 mm, respectively, and its shear strength was 2.40 times that of steel pipe piles. The shear key attached to the inside of thin wall steel tube did not affect the flexural behavior of HCFT piles. It was also observed that the flexural strengths of HCFT piles with diameters of 450 and 500 mm were 35 to 63% higher than the sum of the flexural strengths of its components, respectively, because the strength of concrete in compressive zone increased by confining effect of thin wall steel tube on concrete. HCFT piles used as upper piles in hybrid composite piles might decrease the lateral displacement and increase the structural safety of structures subjected to lateral loads.

Development of Steel-Concrete Composite Lining Board using Section Shape Steel (형강을 이용한 강-콘크리트 합성복공판 기술개발)

  • Oh, Soo-Cheol;Yang, Hae-Sool
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.67-75
    • /
    • 2008
  • This research is to develop the steel-concrete composite lining board using section shape steel. This lining board adopts section shape steel, rectangular pipe and H-beam, instead of roll-formed steel member commonly used in other composite lining board. Consequently, it reduces fabrication effort. Efficient section which can reduce the weight of steel of the lining board is made by placing the neutral axis of the section near the lower surface of concrete. Behavior of composite section is improved by adding bolts as shear connector. Static and fatigue tests were conducted to verify the performance of the composite lining board developed. The test results indicate that serviceability as well as safety of the lining board developed is secured with good margin and reduction of steel weight can be made about 27% compared with other composite lining boards.