• Title/Summary/Keyword: composite pile

Search Result 192, Processing Time 0.031 seconds

Characterization of Composite Ground Reinforced with Recycled-Aggregate Porous Concrete Pile (RAPP) (순환골재 다공질 콘크리트말뚝(RAPP)에 의해 보강된 복합지반의 거동 특성)

  • You, Seung-Kyong;Kim, Se-Won;Lee, Chul-Ho;Choi, Hang-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.117-130
    • /
    • 2009
  • In this paper, a series of laboratory chamber tests were carried out to evaluate the applicability of a porous concrete pile fabricated with recycled aggregates (RAPP) for the soft ground improvement. While performing the laboratory chamber tests for the RAPP, the surface settlement, excess pore pressure and vertical stress distribution with time were compared with those of SCP provided by You (2003) under the same experimental condition. In addition, the experimental results were compared with the numerical simulation using ABAQUS in this study. The results show that the settlement reduction is significantly enhanced due to the stress-sharing mechanism between the RAPP and soil formation by stress concentration on the RAPP. Furthermore, the comparison of consolidation rate shows that the RAPP can accelerate consolidation as well, which behaves as a vertical drain.

Numerical Analysis on the Behavior of Revetment Reinforced by Sand Compaction Pile According to Area Replacement Ratio (수치해석을 이용한 모래다짐말뚝 치환율에 따른 호안 구조물의 거동 분석)

  • Kim, Byoung-Il;Bong, Tae-Ho;Han, Jin-Tae;Jang, Young-Eun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • Sand compaction pile (SCP) is a ground improvement method which is used to secure the stability of the soft ground by using a type of replacement pile filled with coarse grained material. The behavior characteristics of the SCP, which is frequently used for improving both the onshore and offshore ground, is governed by the ground condition, the installation method, and replacement ratio. Therefore, the stability of the SCP in terms of the bearing capacity and displacement needs to be evaluated considering both the design values and in-situ conditions of construction site. In this study, numerical analysis is carried out based on the conditions of 00 revetment construction site in South Korea where unexpected displacement occurred during construction of SCP. Based on the analysis results, the displacement of the revetment structure according to the replacement ratio of the SCP was compared to the result calculated from design formulas. The results showed that the lateral displacement can be exceeded the reference value from proposed criteria regardless of increased replacement ratio of SPC. It is also confirmed that the behavior of the structure according to the replacement ratio of SPC in not reflected in the existing calculation methods. Therefore, the stability of the SCP composite ground should be examined through the site inspection after the SCP construction.

Experimental Study on the Shear Strength of Form Tie Connector Linked by Stud Coupler (스터드 커플러로 연결된 폼타이 연결재의 전단내력에 관한 실험 연구)

  • Seo, Soo-Yeon;Kim, Seoung-Soo;Yoon, Yong-Dae;Ha, Gee-Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.573-581
    • /
    • 2008
  • In general, conventional sheeting H-pile is often used as a temporary member installed upon construction of outer retaining wall at basement floor. In CBW (composite basement wall), R/C basement wall is combined with H-Pile and resists lateral soil pressure together. This paper presents an experimental results of push out shear test of CBW with stud coupler as shear connectors to combine H-Pile with R/C wall six specimens with different diameter of FT (form tie) and arrangement of shear connectors were tested to evaluate the shear capacity of the composite wall. Test results showed that shear strength increased with diameter of FT. The shear strength of shear connector in CBW could be suitably predicted by using the previous equations codified in the codes. Best correlation, especially, was found when the calculation result by the formula in AISC 360-05 was compared to test one.

Calculation models and stability of composite foundation treated with compaction piles

  • Cheng, Xuansheng;Jing, Wei
    • Geomechanics and Engineering
    • /
    • v.13 no.6
    • /
    • pp.929-946
    • /
    • 2017
  • Composite foundation treated with compaction piles can eliminate collapsibility and improve the bearing capacity of foundation in loess area. However, the large number of piles in the composite foundation leads to difficulties in the analysis of such type of engineering works. This paper proposes two simplified methods to quantify the stability of composite foundation treated with a large number of compaction piles. The first method is based on the principle of making the area replacement ratios of the simplified model as the same time as the practical engineering situation. Then, discrete piles arranged in a triangular shape can be simplified in the model where the annular piles and compacted soil are arranged alternately. The second method implements equivalent continuous treatment in the pile-soil area and makes the whole treated region equivalent to a type of composite material. Both methods have been verified using treated foundation of an oil storage tank. The results have shown that the differences in the settlement values obtained from the water filled test in the field and those calculated by the two simplified methods are negligible. Using stability analysis, the difference ratios of the static and dynamic safety factors of the composite foundation treated with compaction piles calculated by these two simplified methods are found to be 3.56% and 5.32%, respectively. At the same time, both static and dynamic safety factors are larger than the general safety factor, which should be greater than or equal to 2.0 according to the provisions in civil engineering. This indicates that after being treated with compaction piles, the bearing capacity of the composite foundation is effectively improved and the foundation has enough safety reserve.

Characteristics on Shear Strength and Clogging Phenomenon of Bottom Ash and Rammed Aggregate Mixture Compaction Pile (쇄석과 저회의 혼합다짐말뚝의 전단강도와 Clogging 현상 규명)

  • Lee, Dongyeup;Kang, Hyongnam;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.3
    • /
    • pp.33-41
    • /
    • 2010
  • The rammed aggregate compaction pile method is widely used as soft ground improvement method because of the installed piles improve not only overall composite capacity but also discharge capacity. But the discharge capacity is declined when the clogging is generated due to the clay penetration into voids of rammed aggregate compaction pile with the time elapsed. The purpose of this study is to reduce the clogging problem occurred in rammed aggregate compaction pile constructed in the soft ground and to minimize voids of rammed aggregate compaction pile. The proper mixing ratio was determined which is based on the results of the large scale direct shear tests conducted to get strength and permeability as optimum mixing ratio of crushed stone and bottom ash. The test results indicated that the highest internal friction angle was obtained at 80:20 mixing ratio of crushed stone and bottom ash. The internal friction angle was declined when the mixing ratio of the bottom ash increased over 20%. The results of the clogging tests, presented that the mixture of 80:20 crushed stone and bottom ash is highest effective of clogging than ratio of pure crushed stone.

Horizontal Behavior Characteristics of Umbrella-Type Micropile Applied in Sandy Soil Subjected to Seismic Motion (사질토 지반에 설치된 우산형 마이크로파일의 지진 시 수평거동 특성)

  • Kim, Soo-Bong;Son, Su Won;Kim, Jin Man
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.7
    • /
    • pp.5-16
    • /
    • 2020
  • Currently, the seismic design standards have been strengthened due to the occurrence of the Gyeongju and Pohang earthquake, and seismic performance evaluation of existing facilities is being conducted. It aims to secure a seismic performance effect during earthquakes by improving the micro-pile method, which can be constructed in limited confined places while minimizing damage to existing facilities. The improvement method is to construct all the piles in the square-tray-type plate on the top of the pile by constructing the slope pile in the form of an umbrella around the vertical pile, the main pillar. In this paper, the numerical analysis was performed to analyze the horizontal displacement behavior of an umbrella-type micropile for various real-measurement seismic waves in sandy soil. As a result of numerical analysis, the softer the ground, the better the effect of horizontal resistance of umbrella-type micropile. The horizontal displacement reduction effect was pronounced when the embedded depth was 15 m or more at the same ground strength, and it was found to be effective in earthquakes if it was settled on the ground with an N value of 30 or more. The embedded depth and horizontal displacement suppression effect of the micropile was proportional. Generally, the weaker the ground, the greater the displacement suppression effect. Umbrella-type micropile had a composite resistance effect in which the vertical pile resists the moment and inclined pile resists the axial force.

Calculation method and application of natural frequency of integrated model considering track-beam-bearing-pier-pile cap-soil

  • Yulin Feng;Yaoyao Meng;Wenjie Guo;Lizhong Jiang;Wangbao Zhou
    • Steel and Composite Structures
    • /
    • v.49 no.1
    • /
    • pp.81-89
    • /
    • 2023
  • A simplified calculation method of natural vibration characteristics of high-speed railway multi-span bridge-longitudinal ballastless track system is proposed. The rail, track slab, base slab, main beam, bearing, pier, cap and pile foundation are taken into account, and the multi-span longitudinal ballastless track-beam-bearing-pier-cap-pile foundation integrated model (MBTIM) is established. The energy equation of each component of the MBTIM based on Timoshenko beam theory is constructed. Using the improved Fourier series, and the Rayleigh-Ritz method and Hamilton principle are combined to obtain the extremum of the total energy function. The simplified calculation formula of the natural vibration frequency of the MBTIM under the influence of vertical and longitudinal vibration is derived and verified by numerical methods. The influence law of the natural vibration frequency of the MBTIM is analyzed considering and not considering the participation of each component of the MBTIM, the damage of the track interlayer component and the stiffness change of each layer component. The results show that the error between the calculation results of the formula and the numerical method in this paper is less than 3%, which verifies the correctness of the method in this paper. The high-order frequency of the MBTIM is significantly affected considering the track, bridge pier, pile soil and pile cap, while considering the influence of pile cap on the low-order and high-order frequency of the MBTIM is large. The influence of component damage such as void beneath slab, mortar debonding and fastener failure on each order frequency of the MBTIM is basically the same, and the influence of component damage less than 10m on the first fourteen order frequency of the MBTIM is small. The bending stiffness of track slab and rail has no obvious influence on the natural frequency of the MBTIM, and the bending stiffness of main beam has influence on the natural frequency of the MBTIM. The bending stiffness of pier and base slab only has obvious influence on the high-order frequency of the MBTIM. The natural vibration characteristics of the MBTIM play an important guiding role in the safety analysis of high-speed train running, the damage detection of track-bridge structure and the seismic design of railway bridge.

Effect of Bilayer Thickness on Hardness of Ag/Ni Nanoscale Multilayers (Ag/Ni 나노다층박막의 경도에 미치는 Bilayer 두께의 영향)

  • Kang Bong Cheol;Kim Hee Yeoun;Kwon Oh Yeol;Lim Byung Kyu;Hong Soon Hyung
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.23-26
    • /
    • 2004
  • Ag/Ni multilayers with different bilayer thickness between 3 and 100 nm produced by DC magnetron puttering have been studied by cross-sectional TEM and nanoindentation. The micrograph shows perfect layered structure with sharp interfaces between Ag and Ni layers. Absolute hardness is calculated as a reference value to compare hardness of specimens regardless of indent depth. A hardness enhancement of nearly $100\%$ over the rule-of-mixtures values, calculated from the measured hardness of single Ag and Ni thin films, is observed. The hardness increases with decreasing bilayer thickness until 8nm. This enhancement shows a good agreement with Hall-Petch relation using grain size (one half of the bilayer thickness) confined within a layer. The deformation behavior can be explained by dislocation pile-up in smaller grains.

  • PDF

Smear Effect on Consolidation Behaviors of SCP-improved Ground (SCP 개량지만의 압밀거동에 대한 스미어 효과)

  • Kim, Yun-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.2
    • /
    • pp.59-66
    • /
    • 2004
  • Sand compaction pile (SCP)-improved ground is composite soil which consists of the SCP and the surrounding soft soil. When a surcharge load is applied to composite ground, time-dependent behaviors occur in the composite soil due to consolidation according to radial flow toward the SCP. In addition, stress transfer also takes place between the SCP and the soft soil. This paper presents the numerical results of cylindrical composite ground that was conducted to investigate smear effect on consolidation behaviors of SCP-improved ground. The results showed that the smeared zone of soft clay had a significant effect on effective stress-pore water pressure response, stress transfer mechanism and stress concentration ratio of composite ground. Amount of stress transfer between the clay and the SCP was maximum in depth of z/H=0.25, and decreased with depth. Stress concentration ratio of composite ground was not constant, but depended on consolidation process. It was also found that the value of stress concentration ratio in soft clay with smeared zone was larger than that in soft clay without smeared zone.

Development of the Hybrid CFFT Pile (FRP-콘크리트 합성말뚝의 개발)

  • Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.2
    • /
    • pp.20-28
    • /
    • 2010
  • In this paper, new type CFFT (Concrete Filled FRP Tube) was suggested in order to improve the flexural stiffness. Since the existing CFFT was produced by filament winding process, re-bar for concrete may be necessary in order to ensure structural safety under flexure re-bar. In comparison with existing type CFFT, new type CFFT was reinforced by circular shaped pultrusion FRP without re-bar. Filament winding FRP was attached to the outer layer of pultrusion FRP. Structural behavior of new type CFFT filled with concrete (HCFFT) was investigated by the mechanical property test for the component element and the FE analysis. Furthermore, compressive strength of the HCFFT member based on the equation suggested in previous studies.

  • PDF