• 제목/요약/키워드: composite pile

검색결과 192건 처리시간 0.029초

합성 지하벽의 전단내력 산정에 관한 실험적 연구 (Experimental Study on the Shear Capacity of Composite Basement Walls)

  • 김성만;이성호;서수연;이리형;홍원기;장재호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.379-384
    • /
    • 2001
  • This paper presents the experimental result of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector. Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, arrangement of shear connector, thickness of wall, shear span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

  • PDF

지반보강용 그라우팅 말뚝의 응력분담비에 대한 수치해석적 연구 (Numerical Study on the Stress-distribution Ratio of Grouting Pile for Reinforced Ground)

  • 이경주;이준규;張維維;송기일
    • 한국지반공학회논문집
    • /
    • 제39권2호
    • /
    • pp.19-30
    • /
    • 2023
  • 연약지반 대책공법으로 적용되는 다짐모래말뚝과 같은 지중구조물은 주로 복합지반 설계법에 의해 침하 및 안정성을 분석한다. 복합지반 설계법의 기본원리는 아칭효과이며 말뚝의 보강효과는 응력분담비로 평가한다. 탄성적 특성을 갖는 그라우팅 말뚝을 지반보강공법으로 적용할 때 기존의 응력분담비 평가는 말뚝이 지표까지 설치되어 상재하중이 말뚝과 원지반에 같이 직접 재하되는 경우만을 고려해 왔다. 본 연구에서는 지반보강 말뚝의 설치를 지표까지 올리지 않고 지중 어느 위치에서 마감할 때에는 지금까지의 연구들에 의해 적용된 응력분담비 적용 방법이 달라져야 한다는 것을 보여주었다. 고강도 Jet grouting이 적용되었을 때 원지반에 대한 그라우팅 말뚝의 응력분담비(n)는 통상 30~50 범위의 값을 적용한다. 그러나 이는 지표까지 말뚝이 놓이는 경우이고 말뚝 상단의 위치가 지표로부터 멀리 깊게 위치될 경우 응력분담 효과가 급격히 저감되며 응력구(stress bulb) 경계가 되는 깊이부터는 정량적 값 1.5에 수렴했다.

내부충전 콘크리트와 횡보강 및 축방향 철근으로 보강된 PHC 말뚝의 휨강도 (Flexural Strength of PHC Pile Reinforced with Infilled Concrete, Transverse and Longitudinal Reinforcements)

  • 방진욱;현정환;이방연;이승수;김윤용
    • 콘크리트학회논문집
    • /
    • 제25권1호
    • /
    • pp.91-98
    • /
    • 2013
  • PHC 말뚝은 우수한 축하중 저항 능력에 비해 상대적으로 전단 및 휨 저항 성능이 낮은 단점을 가지고 있다. 이 연구의 목적은 기존 PHC 말뚝의 단점을 개선할 목적으로 개발된 중공부에 내부충전 콘크리트, 축방향 철근과 전단 철근으로 보강한 합성 PHC 말뚝(ICP 말뚝)의 휨성능을 평가하는 것이다. 이를 위하여 기존의 교대 설계사례로 부터 말뚝에 발생하는 축력과 휨모멘트를 조사한 후, ICP 말뚝 계산을 위하여 개발한 축력-휨모멘트 상관관계 프로그램을 이용하여 허용 축력과 휨모멘트가 발생하는 부재력을 만족하도록 ICP 말뚝을 설계하였다. 설계에 따라 ICP 말뚝을 제작하였으며, 휨실험을 수행하였다. 실험 결과 ICP 말뚝은 PHC 말뚝에 비하여 약 45% 큰 휨내력을 나타내었다. 또한 계산에 의해 예측한 ICP 말뚝 휨강도의 25%를 허용 휨모멘트로 취할 경우, 약 4.5의 안전율을 갖는 것으로 평가되었다.

GCP 복합지반의 거동분석을 위한 유한요소해석 (Finite Element Analysis for Investigating the Behavior of Gravel Compaction Pile Composite Ground)

  • 김경업;박경호;김호연;김대현
    • 한국지반신소재학회논문집
    • /
    • 제17권3호
    • /
    • pp.19-32
    • /
    • 2018
  • GCP(Gravel Compaction Pile, 이하 GCP)공법은 현재 정량적인 설계법이 제시되어 있지 않아 경험적인 방법에 의해 설계 및 시공되고 있어 팽창파괴, 전단파괴 등 다양한 형태의 파괴가 빈번히 발생하고 있으나 명확한 원인 규명과 파괴 예방 대책수립이 어려운 실정이다. 또한 국내와 시공 장비, 재료 특성 등이 다름에도 불구하고 해외의 지반에 적용하는 공법을 그대로 국내에 적용하고 있어 지지력, 침하량 등이 실측값과 큰 차이를 나타내고 있다. 본 연구에서는 GCP공법의 합리적이고 안전한 설계법을 제안하기 위한 연구로써 국내 점토지반에 GCP공법을 적용하여 지반강도 변화에 따른 침하 및 응력 거동특성을 분석하고자 하였다. 이를 위해 ABAQUS를 이용하여 복합지반의 침하량과 침하감소율, 응력분담비, GCP의 최대 수평변위량 및 발생 예상위치를 분석하고자 하였다. 분석 결과, 치환율 30%이상에서 복합지반의 침하감소율이 60%이상 감소하는 것을 확인하였고, GCP의 최대 수평변위량은 말뚝 직경의 2.6배의 깊이에서 발생하였으며, 치환율 40%이상에서는 수평변위량의 차이가 미미한 것을 확인하였다.

파괴기구에 근거한 역 T형 합성지하벽의 강도평가 (Strength Evaluation of Inverted T-shaped Composite Basement Wall Based on Failure Mechanisms)

  • 박지환;서수연;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.415-420
    • /
    • 2003
  • This Study is performed to analyze the behavior of inverted T-shaped Composite Basement Wall(CBW). For this, it is purposed to analyze the failure mechanisms of inverted T-shaped composite basement wall and propose the method of evaluating strength for design. The failure mechanisms would be devided into 4 type mechanisms from previous experimental results, that is hanger failure, punching shear failure, flexural failure and the buckling of H-pile. A strength evaluation procedure for CBW is induced by analyzing respective failure mechanism. Then, the strength for actual structure consisted of inverted T-shaped composite basement wall was evaluated and the expected failure mechanism was determined.

  • PDF

용탕단조법에 의한 AC4A/SiCw 복합재료 제조에 관한 연구(III) - 기계적 특성 - (Fabrication of AC4A/SiCw composite by squeeze casting (III) - Mechanical characteristics -)

  • 문경철;이준희;윤의박
    • 열처리공학회지
    • /
    • 제7권3호
    • /
    • pp.160-168
    • /
    • 1994
  • This was studied about mechanical characteristic of AC4A/SiCw 10-30% reinforced composites. Tensile strength of pressed base metal(base metal) with SiCw preform was higher than without pressed base metal(AC4A). If SiCw whisker volume fraction was increased, tensile strength at room temperature was increased. And tensile strength of SiCw 30% was about $35kg/mm^2$. Tensile strength of SiCw 30 % $400^{\circ}C$ at same time aging was the most excellence, about $40kg/mm^2$. The fracture energy value of composite material at three point bending test was higher than AC4A. Dislocation at matrix of composite material was evenly distributed. But dislocation around whisker of composite material was more existed than matrix. The reasom was thought of pile-up around whisker.

  • PDF

3차원 유한요소법을 이용한 강관합성 말뚝재료의 수평저항력 고찰 (Study on lateral resistance of steel-concrete composite drilled shafts by using 3D FEM)

  • 이주형;신휴성;최상호;박재현;정문경;곽기석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.683-690
    • /
    • 2008
  • Steel-concrete composite columns are popular for superstructures of bridges, and the outside steel attached to the shaft increases the shaft resistance due to confining concrete. In this study, lateral resistance of steel-concrete composite drilled shafts was evaluated quantitatively based on numerical analysis when steel casings are used as structural elements like composite columns. Ultimate lateral resistance of composite drilled shafts with various diameters was numerically calculated through 3D finite element analysis. For that, elasto-plastic model with perfectly plasticity is involved to capture the ultimate load. A commercial FEM program, MIDAS-GTS, is used in this study. Real field conditions of the West Coast, Korea were considered to set up the ground conditions and pile lengths required for this parametric studies. Detailed characteristics of the stress and displacement distributions are evaluated for better understanding the mechanisms of the composite shaft behavior.

  • PDF

수치해석적 방법에 의한 저회혼합다짐말뚝의 침하저감비에 관한 연구 (Numerical Study of Settlement Reduction Ratio for the Bottom Ash Mixture Compaction Pile)

  • 주익찬;김구영;도종남;조현수;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제13권3호
    • /
    • pp.53-58
    • /
    • 2012
  • 일반적으로 연약지반인 점성토 지반이나 느슨한 사질토 지반을 개량하기 위하여 모래다짐말뚝(SCP)공법 또는 쇄석다짐말뚝(GCP)공법이 쓰여지고 있다. 하지만 모래다짐공법은 모래의 수급부족과 모래채취로 인한 환경파괴와 같은 문제점이 있으며, 쇄석다짐공법은 쇄석다짐재료의 클로깅으로 인하여 배수재의 투수계수가 저하되는 문제점이 있다. 최근, 모래와 공학적 성질이 유사한 화력발전소 부산물인 저회를 모래의 대체 재료로 활용하기 위한 연구가 이루어지고 있다. 본 연구에서는 저회혼합다짐말뚝에 대한 기초적 연구로써 조립재료 및 치환율에 따른 조립재료 혼합다짐말뚝의 거동특성을 수치해석적으로 규명하였다. 특히, 말뚝중심부로부터 거리에 따른 침하저감비(SRR)를 산정하였다. 연구 결과는 다음과 같았다. 조립재료에 따른 혼합다짐말뚝의 침하저감비 변화값은 유사한 형태를 보였으며 치환율에 따라 복합지반의 강성이 증대하여 침하저감비는 감소하는 형태를 보였다. 특히, 치환율 20~40%의 범위에서는 일반적으로 침하저감비의 증가가 큰 것으로 나타났고, 치환율 40% 이상에서는 증가치가 서서히 감소하는것으로 나타났다. 본 연구에서 적용한 연약지반과 유사한 지반에 혼합다짐말뚝 적용 시 경제성을 고려하였을 때, 30~40%의 치환율이 적절할 것으로 사료된다.

다짐말뚝으로의 점토혼입현상에 관한 실험적 연구 (Experimental Study of Clays Mixed into Compaction Piles)

  • 유승경;김주현
    • 한국지반신소재학회논문집
    • /
    • 제8권4호
    • /
    • pp.41-46
    • /
    • 2009
  • 본 논문에서는 순환골재 다공질 콘크리트말뚝(Recycled-Aggregate Porous Concrete Pile, RAPP)을 비롯한 각종 다짐말뚝공법(SCP와 GCP)에 대하여 원지반의 구속압에 기인한 다짐말뚝으로의 점토혼입현상이 개량된 지반의 압밀촉진효과에 미치는 영향을 파악하기 위하여 일련의 실내모형실험을 수행하였다. 모형실험에서는 모형지반의 압밀도를 50%, 100%의 상태로 원지반을 모사하였으며 다짐말뚝을 조성한 복합지반에 대해서는 심도 5m에 상응하는 구속압을 적용하였다. 또한 각각의 다짐말뚝으로의 점토 혼입량은 포화된 다짐말뚝으로부터의 배수량을 측정하여 추정하였다. 모형실험 결과를 통하여 다짐말뚝의 종류에 따라 원지반의 압밀 진행 상태에 따라서 연직배수기능을 담당하는 다짐말뚝의 통수 단면적이 변화하는 경향을 파악할 수 있었다. 즉, 상대적으로 큰 간극비를 갖는 쇄석다짐말뚝에서 가장 많은 통수 단면적의 변화가 관측되었으나 원지반의 압밀이 진행된 상태일수록 그 변화량은 감소함을 알 수 있었다.

  • PDF