• Title/Summary/Keyword: composite pile

Search Result 192, Processing Time 0.023 seconds

A Numerical Study on Granular Compaction Pile Method Reinforcing by Using Lean-Mixed Concrete (빈배합 콘크리트로 보강된 조립토 다짐말뚝공법에 관한 기초연구)

  • Kim, Seung-Wook;Kim, Hong-Taek;Kim, Jeong-Ho;Baek, Seung-Cheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.1
    • /
    • pp.5-18
    • /
    • 2006
  • Stone column or granular compaction pile have been used in widely during the several decades as a technique to reinforce soft cohesive soils and increase bearing capacity, accelerate consolidation settlement of the foundation soil. The bearing capacity of the granular compaction pile is governed mainly by the lateral confining pressure mobilized in the native soft soil to restrain bulging collapse of the granular pile. Therefore, the technique becomes unfeasible in soft, compressible clayey soils that do not provide sufficient lateral confinement. This paper presents the main results of numerical study of granular compaction pile which is partly mixed with lean concrete. 3D finite element analyses are performed with composite reinforced foundations by both granular compaction pile and partly mixed granular compaction pile with lean-mixed concrete. Finally, a regression formula for calculating settlement reduction coefficients is proposed in this study by using numerical analysis results and applicability of the proposed method is identified by a series of parametric study about settlement reduction coefficients.

  • PDF

A Study on the Settlement Restraint of the Granular Compaction Pile (조립토 다짐말뚝의 침하저감방안에 관한 연구)

  • Kim, Seung-Wook;Lee, Duck-Won;Kim, Seo-Ryong;Ann, Jai-Gyoo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.336-342
    • /
    • 2005
  • Stone column or granular compaction pile have been used in widely during the several decades as a technique to reinforce soft cohesive soils and increase bearing capacity, accelerate consolidation settlement of the foundation soil. The bearing capacity of the granular compaction pile is governed mainly by the lateral confining pressure mobilized in the native soft soil to restrain bulging collapse of the granular pile. Therefore, the technique becomes unfeasible in soft, compressible clayey soils that do not provide sufficient lateral confinement. This paper presents the main results of numerical study of granular compaction pile which is partly mixed with lean concrete. 3D finite element analyses are performed with composite reinforced foundations by both granular compaction pile and partly mixed granular compaction pile with lean-mixed concrete.

  • PDF

Development of New Settlement Model for Prediction of Settlement Characteristics of SCP Composite Ground (SCP 복합지반 침하거동예측을 위한 새로운 침하모델의 개발)

  • You, Sang-Ho;Park, Hyun-Il;Im, Jong-Chul;Park, Lee-Keun
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.8
    • /
    • pp.23-32
    • /
    • 2009
  • In this study, the reliable and simple analysis method was proposed to predict the settlement characteristic of composite ground in stage of design and construction of sand compaction pile (SCP). Model parameters could be obtained by the optimization process based on genetic algorithm. In order to examine the proposed method, laboratory consolidation tests on the settlement characteristic of SCP composite ground were performed for various replacement ratio of sand such as 0 (no replacement), 20, 36, and 56%. The proposed model showed very good agreements with measured data in the relation of void ratio-log scaled stress and time-compression far each replacement ratio.

Characteristics of Settlement Reduction and Consolidation Behavior of Composition Ground Improved by Recycled-Aggregate Porous Concrete Pile (순환골재 다공질 콘크리트말뚝으로 개량된 복합지반의 침하저감 및 압밀거동 특성)

  • You, Seung-Kyong;Kim, Se-Won;Choi, Hang-Seok;Lee, Chang-Min
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.3
    • /
    • pp.25-30
    • /
    • 2008
  • In this research, the characteristics of settlement and consolidation behavior of the composite ground formation reinforced by Recycled-Aggregate Porous Concrete Pile (RAPP) were evaluated by conducting a series of laboratory chamber tests. The effect of settlement reduction was verified by comparing the settlement of the composite ground formation with that of the unreinforced ground. In addition, it was studied how much the RAPP can accelerate consolidation in assessment of the degree of consolidation in the composite ground formation. The amount of settlement reduction was decreased with an increase on surcharge pressure, but it was greater than that of the SCP method. The RAPP and the SCP showed a similar rate of consolidation.

  • PDF

The Structural Characteristics of Non-slip Device in Connecting Method Between Steel Pipe Pile and Footing (미끌림 방지턱을 이용한 강관말뚝 머리 결합부의 구조특성에 관한 실험적 연구)

  • 박영호;김낙영
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.227-243
    • /
    • 2003
  • To find the structural characteristics of non-slip device in connecting method B between steel pipe pile and concrete footing, compression and uplift test was performed for full sized specimens not having non-slip device, those having non-slip device with two curved steel plate bars welded inside the steel pipe pile(standard method), and those having non-slip device with serveral curved steel plate bars bolted inside the steel pipe pile(new method). As a result, specimens not having non-slip device had chemical debonding failure at 15.6tonf of peak uplift load and 27.57tonf of peak compression load. And the standard method and the new method showed about 8.9 times of peak uplift load and 6.2 times of peak compression load higher than specimens not having non-slip device. The load transfers of lower non-slip devices of the standard method and the new method were similar in behavior, while the higher non-slip device of the new method showed higher ratio of load transfer than that of the standard method. And these two methods had nearly the same composite action and structural capacity caused by non-slip devices.

An Evaluation of Flexural Strength of Hollow Concrete Filled FRP Tube Piles (중공형 콘크리트 충전 FRP Tube 말뚝의 휨강도 산정)

  • Kim, Hyung-Joon;Chung, Heung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.204-211
    • /
    • 2022
  • In this study, Hollow Concrete Filled FRP Tube Pile(HCFFT Pile) was proposed as a model to utilize the advantages of composite piles and solve the problem of corrosion, which is a disadvantage of CFT piles, and a numerical analysis model was developed to analyze their behavior. The strain compatibility method was applied considering the damage plastic behavior of concrete, the yield plastic behavior of steel, and the elastic behavior of FRP. The flexural strength calculation equation of HCFFT piles was proposed considering the change of the FRP tube section according to the distance from the neutral axis. The flexural strength calculation equation, numerical analysis results, and experimental results were compared and analyzed to verify their adequacy. The results of this study can be used as basic data for the optimal design of various HCFFT piles using FRP.

Numerical study for Application of H-Pile Connection Plastic Sheet Pile Retaining Wall (HCS) (H-Pile과 Plastic Sheet Pile을 결합한 토류벽체에 대한 수치해석적 연구)

  • Lee, Kyou-Nam;Lim, Hee-Dae
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.331-343
    • /
    • 2017
  • In this study to improve stability, workability and economics of the H-Pile+Earth plate or H-Pile+Earth plate+Cutoff grouting currently in use, we had developed HCS method belonging to the retaining wall which is consisting of a combination H-Pile, Plastic Sheet Pile and Steel Square Pipe for gap maintenance and reinforcement of flexible plastic Sheet Pile, and the behavior of each member composing HCS method is investigated by three-dimensional finite element analysis. To numerically analyze the behavior of the HCS method, we have performed extensive three-dimentional finite element analysis for three kinds of plastic Sheet Pile size, two kinds of H-Pile size and three kinds of H-Pile installation interval, one kinds of Steel Square Pipe and three kinds of Steel Square Pipe installation interval. After analyzing the numerical results, we found that the combinations of $P.S.P-460{\times}131.5{\times}7t$ (PS7) and H-Pile $250{\times}250{\times}9{\times}14$ (H250), $P.S.P473{\times}133.5{\times}9t$ (PS9) and H-Pile $300{\times}200{\times}9{\times}14$ (H300) is the most economical because these combinations are considered to have a stress ratio (=applied stress/allowable stress) close to that as the stiffness of H-Pile, plastic Sheet Pile and Steel Square Pipe composite increased, the horizontal displacement of the retaining wall and the vertical displacement of the upper ground decreased. Especially, due to the arching effects caused by the difference in stiffness between H-Pile and plastic Sheet Pile, a large part of the earth pressure acting on plastic Sheet Pile caused a stress transfer to H-Pile, and the stress and displacement of plastic Sheet Pile were small. Through this study, we can confirm the behavior of each member constituting the HCS method, and based on the confirmed results of this study, it can be used to apply HCS method in reasonable, stable and economical way in the future.

An Experimental Study on the Behavior of Composite Ground Improved by SCP and GCP with Low Replacement Ratio (저치환율 SCP와 GCP로 개량된 복합지반의 거동에 관한 실험적 연구)

  • Kim, Byoung-Il;Yoo, Wan-Kyu;Kim, Young-Uk;Moon, In-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.936-942
    • /
    • 2013
  • This paper presents the results of laboratory tests conducted to investigate the effectiveness of applying methodology of a sand compaction(SCP) and a gravel compaction pile(GCP) on soft ground. The test conditions involved relatively low replacement ratios (=10, 20, and 30%) of a pile to unit cell at 1g (gravity acceleration) level. Results revealed that GCP significantly enhanced bearing capacity, settlement reduction, and consolidation rate compared with SCP.