• Title/Summary/Keyword: compliance control

Search Result 692, Processing Time 0.025 seconds

A Study on the Development, Performance and Reliability Certification for Fire Detection System in Outdoor Area (옥외형 화재경보시스템의 개발과 성능시험에 관한 연구)

  • Baek, Dong-Hyun;Ghil, Min-Sik
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.15-18
    • /
    • 2013
  • This paper is concerned with the Performance and Reliability Certification for fire detection system in outdoor area such small and middle sized cultural assets, natural monument and outdoor facilities. Especially, if a fire were to occur in vulnerable area, it is difficulty to detect a fire. therefore we propose a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. for Adoption of Intelligent Fire Detection System with movable and unmanned function breaking from the existing Conventional Fire Detection System, this Range of R&D includes the Performance test, Function test, Field test, Flame Detection test and EMI/EMS Compliance test. the Result data of Performance test, Function test and Field test is generally good during 3 months. also we checked that thermal variation test and EMI/EMS compliance test are good result data within allowable range. As a result of general test, we verified improvement results that the measure distance of fire detection extend 75 m, the Power of waiting time increase 4 hours, the Power of operation time increase 3 days and the context awareness with video as well as sensors.

Treatment of Latent Tuberculosis Infection and Its Clinical Efficacy

  • Kim, Hyung Woo;Kim, Ju Sang
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.1
    • /
    • pp.6-12
    • /
    • 2018
  • The role of the treatment for latent tuberculosis infection (LTBI) has been underscored in the intermediate tuberculosis (TB) burden countries like South Korea. LTBI treatment is recommended only for patients at risk for progression to active TB-those with frequent exposure to active TB cases, and those with clinical risk factors (e.g., immunocompromised patients). Recently revised National Institute for Health and Care Excellence (NICE) guideline recommended that close contacts of individuals with active pulmonary or laryngeal TB, aged between 18 and 65 years, should undergo LTBI treatment. Various regimens for LTBI treatment were recommended in NICE, World Health Organization (WHO), and Centers for Disease Control and Prevention guidelines, and superiority of one recommended regimen over another was not yet established. Traditional 6 to 9 months of isoniazid (6H or 9H) regimen has an advantage of the most abundant evidence for clinical efficacy-60%-90% of estimated protective effect. However, 6H or 9H regimen is related with hepatotoxicity and low compliance. Four months of rifampin regimen is characterized by less hepatotoxicity and better compliance than 9H, but has few evidence of clinical efficacy. Three months of isoniazid plus rifampin was proved equivalence with 6H or 9H regimen in terms of efficacy and safety, which was recommended in NICE and WHO guidelines. The clinical efficacy of isoniazid plus rifapentine once-weekly regimen for 3 months was demonstrated recently, which is not yet introduced into South Korea.

Health Behavior and Perception of Therapeutic Restrictions in Chronically Ill Children and Their Parents (만성질환 아동과 부모의 치료적 제한에 대한 인식과 건강행위)

  • Park, Eun-Sook;Im, Yeo-Jin;Im, Hye-Sang;Oh, Won-Oak
    • Child Health Nursing Research
    • /
    • v.12 no.3
    • /
    • pp.405-416
    • /
    • 2006
  • Purpose: The purpose of this study was to explore health behavior and perception of therapeutic restrictions in chronically ill children and their parents in Korea. Method: Nine children with chronic disease and of six of their parents were interviewed using semi-structured a questionnaire. The data were analyzed using explorative content analysis. Results: Health behaviors related to therapeutic restrictions was classified into four domains, and the perceptions of therapeutic restrictions into two domains. The domains regarding compliance in health behavior with therapeutic restrictions included control-centered restrictions (maintaining food limitations, avoiding harmful environments, restriction on physical activity, restriction on social activity, restriction on learning activity), and everyday pursuit of balance(preference for healthy diet, maintaining a regular life style, maintaining a standard body weight, pursuing psychological well-being, family participation). Domains regarding perception of therapeutic restrictions included obstacles to growth and development (bridled life, opportunity deprivation, prevented from playing proper role), origin of conflict (tenacity, conflict, stressor, cover-up), task for normal life (doing proper duty), and everyday affairs (becoming ordinary, familiarity). Conclusion: This study will help to enhance understanding the behavior and perception of therapeutic restrictions by chronically ill children and their families and to establish educational programs and counseling for these children and their families.

  • PDF

Analysis of Hand Hygiene Practices of Health Care Personnels (의료기관 종사자의 손 위생 수행 분석)

  • Oh, Hyang Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6160-6168
    • /
    • 2015
  • Hand hygiene(HH)of the health care personnels(HCPs) was the most effective method to prevent the transmission of healthcare associated infections. This study was conducted to measure and analysis the status of the HH compliance of HCPs. Data were collected by the direct observation methods of the World Health Organizations(WHO) using WHO's HH monitoring tool kits from 25th October to 31th December, 2010. Data were analyzed by descriptive statistics, cross analysis, multiple logistic analysis using the SPSS/PC 21 program. A total of 8,644 opportunities for HH were observed, and the overall HH compliance rate was 94.1%. HH rates of physicians was lowest(83.4%; OR: 0.209, 95%CI:0.174-0.252). HH rates were statistically different by the job titles(p<0.001), WHO's 5 moments(p<0.001). HH rates in registered nurses(p=0.003), and medical technicians(p<0.001) were statistically different by the WHO 5Moments. Jobs specific HH strategies and WHO 5Moments should be developed to increase the HH compliances of the HCPs.

Trade Facilitation for SME's E-Commerce Export - focusing on Customs' risk management (중소기업 전자상거래 수출통관 원활화에 대한 연구 - 위험관리를 중심으로)

  • Ji-Soo Yi
    • Korea Trade Review
    • /
    • v.48 no.2
    • /
    • pp.197-216
    • /
    • 2023
  • This research aims to examine and reevaluate the risk management procedures required for facilitating E-Commerce exports by Small and Medium-sized Enterprises(SMEs) in the context of customs risk management procedures. Based on risk management studies, this research focuses on three research questions. First, what courses comprise the export risk management structure? Second, what are the key issues in risk management in facilitating E-Commerce export clearance? Third, based on the research results, what are the implications and improvements for export customs risk management in boosting SMEs' E-Commerce exports? The research concluded that risk control for SMEs' E-Comerce exports should be further strengthened based on a compliance management approach. To achieve this, the customs authorities should develop a new method of reasoning about the difficulties SMEs face in exporting and the risks of failure to comply with the regulations at the foreign markets.

A Comparison Study between Composite and Multiple Single-Segment Profile Control (Profile의 Composite와 Multiple Single-Segment Control의 비교 연구)

  • Kim, Jun-Ho;Chang, Sung-Ho;Ra, Doo-Wan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.4
    • /
    • pp.1-6
    • /
    • 2016
  • As manufacturing industries become globalized, product design affects every area of organization. The design sets the goals for a number of different departments, so if it fails to effectively communicate these goals, the entire organization is less efficient. In addition, To communicate clearly, the design must represent a product that meets its technical specification. GD&T (Geometric Dimensioning and Tolerancing) is one of the most important factors, which has an effect on efficiency of manufacture system, in designing products. However, most of designers in different industries are prone to ignore the importance of GD&T. To analyse the importance of GD&T compliance with international standards for design drawing, a comparison analysis of the difference between two methods, composite profile control and multiple single segment profile control, is performed on three different cases and suggests how it used to be more suitable. Composite profile tolerance is specified by a dual feature control frame that has one profile symbol specified with two lines of tolerance information. Whereas a multiple single segment profile control is when two or more single segment profile callouts are used to define the location and/or orientation and/or size and/or form of a part feature. In this study, the following results will be provided : a clear definition and an obvious difference of the tolerance zone, datums and datums sequence and minimization of tolerances. On this study, composite profile tolerance and multiple single segment profile tolerance were discussed. Next steps of research will consist on reaching more accurate results for profile control. Further research will be focused on dealing with the remaining 14 symbols of GD&T.

A Proposal of Risk Management Framework for Design as a Secure Power Control System (안전한 전력 제어시스템 설계를 위한 위험관리 프레임워크 제안)

  • Park, Jun Yong;Shin, Sumin;Song, Kyoung-Young
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.425-433
    • /
    • 2016
  • In smart grid, enhancement of efficiency and interoperability of electric power system is achieved through the connection with outer network, and this induces that power grid system is threatened increasingly, becomes the main target of cyber terrorism, and is sincerely required to design the secure power system. Although SSDLC(Secure System Development Life Cycle) is used for risk management from the design phase, traditional development life cycle is somewhat limited for satisfaction of information security indicator of power control system. Despite that power control system should reflect control entities of information security considering its own characteristics, validation elements are insufficient to apply into real tasks based on existing compliance. To make design of diagnostic model and assessment process for power control system possible and to give a direction for information security and present related indicator, we propose the new risk management framework of power control system which is applied operational security controls and standard architecture presented by IEC 62351 TC 57 with enterprise risk management framework.

Study on the Security R&R of OT-IT for Control System Network Boundaries (제어 네트워크 경계에 대한 OT-IT 책임 역할 연구)

  • WOO, Young Han;Kwon, Hun Yeong
    • Journal of Information Technology Services
    • /
    • v.19 no.5
    • /
    • pp.33-47
    • /
    • 2020
  • In recent years, due to the demand for operating efficiency and cost reduction of industrial facilities, remote access via the Internet is expanding. the control network accelerates from network separation to network connection due to the development of IIoT (Industrial Internet of Things) technology. Transition of control network is a new opportunity, but concerns about cybersecurity are also growing. Therefore, manufacturers must reflect security compliance and standards in consideration of the Internet connection environment, and enterprises must newly recognize the connection area of the control network as a security management target. In this study, the core target of the control system security threat is defined as the network boundary, and issues regarding the security architecture configuration for the boundary and the role & responsibility of the working organization are covered. Enterprises do not integrate the design organization with the operation organization after go-live, and are not consistently reflecting security considerations from design to operation. At this point, the expansion of the control network is a big transition that calls for the establishment of a responsible organization and reinforcement of the role of the network boundary area where there is a concern about lack of management. Thus, through the organization of the facility network and the analysis of the roles between each organization, an static perspective and difference in perception were derived. In addition, standards and guidelines required for reinforcing network boundary security were studied to address essential operational standards that required the Internet connection of the control network. This study will help establish a network boundary management system that should be considered at the enterprise level in the future.

Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart (MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

Influencing Factors on the Performance of Healthcare-associated Infection Control and Microbiological Hand Contamination among Caregivers at a Tertiary Hospital (일개 상급종합병원에 근무하는 간병인의 의료관련감염 관리 수행도 및 손의 미생물 오염도에 영향을 미치는 요인)

  • Lee, Hee Jin;Park, Eun Ju;Bak, Mi Hui;Ju, Hye Young;Seo, Joo We;Jeon, Mi Yang
    • Journal of muscle and joint health
    • /
    • v.26 no.3
    • /
    • pp.241-250
    • /
    • 2019
  • Purpose: This study was conducted to identify influencing factors on the performance of healthcare-associated infection control and microbiological hand contamination among caregivers at a tertiary hospital. Methods: The participants of this study were 59 caregivers woring at a tertiary hospital. Data were collected from July 1 to 30, 2018. Data were analyzed using descriptive statistics, t-test, ANOVA, Scheffé test, Pearson's correlation coefficients and stepwise multiple regression by SPSS 23.0 Win program. Results: Multiple regression analysis revealed that factors influencing performance of healthcare-associated infection control were awareness (β=.63, p<.001) and the experience of infection-related education (β=-3.40, p=.042). Regression equations describing the performance of healthcare-related infection control were found to be appropriate (F=27.29, p<.001) and accounted for 68% of variance. Factors affecting the degree of microbiological hand contamination were work experience (β=-0.28, p=.026) and healthcare-related infection performance (β=-0.28, p=.029). A regression equation describing the microbiological hand contamination was appropriate (F=6.10, p=.004) and accounted for 42% of variance. Conclusion: The findings of this study suggest that it is necessary to increase performance of healthcare-associated infection control by caregivers. Also, educations for preventing healthcare-associated infection and guidelines for increasing compliance with healthcare-associated infection control are recommended to improve performance of healthcare-associated infection control.