• Title/Summary/Keyword: complex wastewater

Search Result 218, Processing Time 0.027 seconds

Application of analytic hierarchy process technique for selecting a hydrothermal energy site (수열에너지 입지 선정을 위한 계층화분석법의 적용)

  • Joohyun Ahn;Suwan Park;Changhyun Oh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.69-81
    • /
    • 2024
  • In this study, an evaluation system that can be used to evaluate the feasibility of developing and supplying hydrothermal energy for the operation of large-scale complex facilities was developed. To this end, this study derived factors to be considered when selecting a location for the use of hydrothermal energy using raw water from multi-purpose dams and regional water supply systems through literature survey and expert interviews. The evaluation indicators derived from this study are divided into four sectors: hydrothermal energy utilization factors, location factors, planning factors, and disaster safety factors, and are composed of 10 mid-level indicators and 34 detailed planning indicators. The relative importance of all factors was derived using the Analytic Hierarchy Process (AHP) technique, and the developed evaluation indicators and relative importance were applied to four multi-purpose dam regions in the country. As a result, it was found that in the development and use of hydrothermal energy utilizing regional raw water supply line the urban planning conditions of the supply site can have a greater impact on the location selection results than the hydrothermal energy development itself. Due to the characteristics of the evaluation indicators developed in this study and their nature as comprehensive indicators, it is believed that the results should be applied to determine the overall adequacy of site selection in the early stages of hydrothermal energy development. In the future, it is believed that it will be necessary to analyze the problems in supplying and operating hydrothermal energy using raw water from multi-purpose dams and regional water resources. Based on the analysis the evaluation system developed in this study is expected to be improved and supplemented.

Monitoring of Distribution System to Improve Tap Water Quality (수돗물 수질개선을 위한 배수관망시스템 관리 정책 - 수질모니터링을 중심으로 -)

  • Jun, Jesang;Kim, Jakyum
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.411-420
    • /
    • 2005
  • Maintaining a good quality of drinking water produced through appropriate water treatment processes to the tap is as important as improving water quality in a water treatment plant (WTP). The quality of most tap water, however, does not have the same quality as that of the water produced in a WTP due to the contamination in the distribution system while they are delivered through pipes and water tanks. It is very important to maintain water quality in distribution system to water suppliers for consumer's health and safety. Furthermore, it is not possible to investigate the water quality of all points in the distribution system because the system has a wide area and very complex hydraulic characteristics. One economic solution to prevent water quality in distribution system from being deteriorated is monitoring several points that might have the least water quality in the distribution system. If the quality of water of the monitoring points selected by proper ways is better than the quality index of Drinking Water Quality Guidelines suggested by Korean Ministry of Environment, all other points in the distribution system would be safe to drink.

An Economic Analysis of Desalination for Potential Application in Korea (국내 적용을 위한 해수 담수화 경제성 분석)

  • Park, No Suk;Park, Hee Kyung;Park, Mi Hyun;Kim, Byung Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.48-54
    • /
    • 1998
  • Korea becomes one of the countries which suffer from water shortage. It is expected that its water shortage in the early 2000's will be more than 10% of the annual demand. The shortage problem is more serious in the coastal areas where many industry complex locate. To solve the shortage problem, seawater desalination gets more attention as an alternative water supply source since Korea is surrounded by sea on its three sides. For potential application of seawater desalination in Korea, an economic analysis was conducted using cost data for the plants in the Middle Ease areas, The United states and others. The study is to provide a basis for the government to establish a strategy for promoting seawater desalination in Korea. It is discussed that the Reverse Osmosis (RO) process gets cheaper over times than the thermal processes of Multi-stage Flash Distillation (MSF) and Multi Effect Distillation (ME), especially in case where the capacity is less than about 50,000 ton/day. The unit cost of RO seawater is analyzed about US$1.35/ton in 1990 price. Since the Desalination plant can be operated regardless of weather conditions, industries in Korea's coastal areas which suffer from frequent droughts and water shortages are recommended to look into this option with more attention.

  • PDF

The Influence of Aqueous Ionic, Condition on the Adsorption Features of Fluoride Ion on Waste Oyster Shell (수중 이온 환경이 폐굴껍질에 대한 불소 이온의 흡착 양상에 미치는 영향)

  • Lee, Jin-Sook;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.314-318
    • /
    • 2007
  • The feasibility of the employment of waste oyster shell as an adsorbent for fluoride ion has been tested by considering the effect ionic condition on the adsorption of fluoride ion on oyster shell. The adsorption capacity of oyster shell for fluoride ion was found not to be significantly influenced by the ionic strength of aqueous environment. The existence of complexing agent such as nitrilotriacetic acid in wastewater decreased the adsorbed amount of fluoride ion by forming a stable complex of $CaT^-$ and the adsorption reaction of fluoride ion on oyster shell was examined to be endothermic. The coexisting heavy metal ionic adsorbate in wastewater hindered the adsorption of fluoride ion, however, its adsorbed amount was increased as the particulate size of adsorbent was decreased. Finally, a serial adsorption column test has been conducted for a practical application of adsorption process and the breakthrough of the column adsorption was observed in 22 hours under the experimental condition.

Impact assessment for water pressure and turbidity occurrence by changes in water flow rate of large consumer at water distribution networks (상수도관망에서 대수용가의 유량변화에 따른 수압 및 탁도발생 영향평가)

  • Choi, Doo Yong;Kim, Ju-Hwan;Choi, Min-Ah;Kim, Do-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.277-286
    • /
    • 2014
  • Water discolouration and increased turbidity in the local water service distribution network occurred from hydraulic incidents such as drastic changes of flow and pressure at large consumer. Hydraulic incidents impose extra shear stresses on sediment layers in the network, leading to particle resuspension. Therefore, real time measuring instruments were installed for monitoring the variation of water flow, pressure, turbidity and particulates on a hydrant in front of the inlet point of large apartment complex. In this study, it is attempted to establish a more stable water supply plan and to reduce complaints from customers about water quality in a district metering area. To reduce red or black water, the water flow monitoring and control systems are desperately needed in the point of the larger consumers.

Experimental and mathematical evaluation of solar powered still equipped by nano plate as the principle stage of zero discharge desalination process

  • Jadidoleslami, Milad;Farahbod, Farshad
    • Advances in Energy Research
    • /
    • v.4 no.2
    • /
    • pp.147-161
    • /
    • 2016
  • To start with, finding a sustainable method to produce sweet water and electricity by using renewable energies is one of the most important issues at this time. So, experimental and theoretical analysis of the performance of a closed solar powered still, which is jointed to photovoltaic cells and vacuum pump and equipped by nano plate, as the principle stage of zero discharge desalination process is investigated in this project. Major goal of this work is to reuse the concentrated brine of the Mobin petrochemical complex in order to produce potable, sweet water from effluent saline wastewater and generating electricity in the same time by using solar energy instead of discharging them to the environment. It is observed the increase in brackish water temperature increases the average daily production of solar desalination still considerably. Therefore, the nano plate and vacuum pump are added to augment the evaporation rate. The insolation rate, evaporation rate, the average brackish temperature, ambient temperature, density are investigated during a year 2013. In addition to obtain the capacity of solar powered still, the highest and lowest amount of water and electricity generation are reported during a twelvemonth (2013). Results indicate the average daily production is increased 16%, which represents 7.78 kW.h energy saving comparing with traditional solar still.

A Conceptual Zero-Discharge System for Water Quality Management of the Nak-Dong River (낙동강 수질관리 방안-하수분리 무방류시스템의 개념적 고찰)

  • Park, Hee-Kyung;Hyun, In-Hwan;Park, Chung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.40-49
    • /
    • 1997
  • From water management point of view, the industrialization that we have achieved in the last decades brought out two major changes: water shortage and water quality deterioration. They are getting the big obstacles we must overcome to continuously pursue industrialization for further development in the next century. Many plans using dams and advanced treatment methods have been developed for control of quantity and quality, respectively. In this paper, an alternative is conceptually reviewed which is much different from the plans in regard that the alternative looks at system itself. It is based on an interceptor system coupling with a concept of zero-discharge. This system allows no discharge of wastewaters from point-sources to waterbodies which are very sensitive in terms of water quality. In addition reuse of treated effluents is emphasized to a maximum extent. The application of the system to the Nak-Dong river basin indicated that an interceptor system will need from the middle reaches of the basin where industrialization gets heavier. Since wastewaters are not directly discharged to the river, water quality of the down stream will improve. Treated effluents will be able to be reused at a number of industrial complex which currently get water from the Nak-Dong river. This reuse will help alleviate water shortage. The biggest problem anticipated is cost for building and operating such system. A cost-sharing plan among the beneficiaries is considered. Further research is suggested focusing on detailed engineering and technical matters for potential implementation.

  • PDF

A Study on the Application of Regional Environmental Assessment to Small Area Development -The case of small area development in Hwasung-City, Gyunggi-Do- (소규모 개발사업에 대한 토환경영향성평가 적용에 관한 연구 - 경기도 화성시 소규모 개발 사례를 중심으로 -)

  • Oh, Seung Ryun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.619-630
    • /
    • 2009
  • The study area investigated in this research is Hwaseong city, Gyeonggi-Do where small scale development is currently in progress. For the last three years, we carried out the environmental and ecological assessment by using data from The Ministry of Environment and Han River Basin Environmental Office. Most of development works in Hwaseong city, Gyeonggi-Do are small scale developments which are related with factory and distribution complex based on individual laws and regulations. However, environmental and ecological assessment is not being sufficiently reflected beforehand. Especially, because the development takes place mainly in the outskirts of the city, the fine forest is continuously being damaged. We analyzed changes in green zone caused by the developments. As a result, the percentage of original green zone was decreasing while the percentage of artificial green zone was increasing. We should maintain the percentage of the original green zone in order to conserve natural environment. In the past three years, the damage of the DGN (Degree of Green Naturality, 7) area that has high conservative value was little, but, there was serious damage in the area of DGN 6. In order to conserve natural environment, political and institutional investigation should be seriously carried out for mitigation of environmental and ecological damages.

A Numerical Method to Calculate Drainage Time in Large Transmission Pipelines Filter (대구경 관로의 배수시간 산정을 위한 수치해석 기법)

  • Shin, Byoung-Ho;Choi, Doo-Yong;Jeong, Kwansue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.511-519
    • /
    • 2017
  • Multi-regional water supply system, which installed for supplying multiple water demands, is characterized by large-sized, long-distance, tree-type layout. This system is vulnerable to long-standing service interruption when a pipe breaks is occurred. In this study, a numerical method is proposed to calculate drainage time that directly affects time of service interruption. To begin with, governing equations are formulated to embed the delayed drainage effect by the friction loss, and to resolve complicated connection of pipelines, which are derived from the continuity and energy equations. The nonlinear hydraulic equations are solved by using explicit time integration method and the Newton-Raphson method. The developed model is verified by comparing the result with analytical solution. Furthermore, the model's applicability is validated by the examples of pipelines in serial, in parallel, and complex layout. Finally, the model is utilized to suggest an appropriate actions to reduce the deviation of draining time in the C transmission line of the B multi-regional water supply system.

Optimization of Water-Reusing Network among the Industries in an Eco-Industrial Park Complex Using Water Pinch Technology (워터핀치기술을 이용한 생태산업단지 내 기업간 용수 재이용망 최적화)

  • Kim, Young-Soo;Kim, Hyun-Joo;Lee, In-Beum;Yoo, Chang-Kyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1165-1173
    • /
    • 2008
  • An water-reuse network design has drawn attention as a systematic method of reducing fresh water usage and increasing water-using efficiency. The final goal of an eco-industrial park(EIP) is accomplishing industrial sustainability and constructing water-reuse network can be a solution. When designing water-reuse network connecting various processes which consume water, the water pinch technology can be used frequently, since it simultaneously minimize freshwater usage and wastewater discharge. In this research water pinch technology is applied to develop an effective water-reuse network in an EIP. Three scenarios based on different reusing strategies were developed. The results show that the final water-reuse network can reduce the total fresh water usage more than 30%, while the water expenses decrease by 20%. It can be concluded that water pinch technology is an effective tool to optimize water-reuse network among different industrial facilities.