• 제목/요약/키워드: complex wastewater

검색결과 218건 처리시간 0.029초

섬유 형태에 따른 염색폐수 배출특성 연구 (Studies on the Effluent Characteristics of Dyeing Wastewater by Textile Classification)

  • 이수형;박정민;박상정;정제호
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.881-888
    • /
    • 2007
  • In order to investigate the characteristics of the non-biodegradable material, the $BOD_5/COD_{Cr}$ ratio was used. The average ratio of industrial complex's influent wastewater was 2.29~2.96, the effluent ratio was 4.29~19.0. The removal efficiency of $UV_{254}$ by physicochemical treatment was 22.8~94.7% and 5.3~77.2% by biological treatment, respectively. Of the wastewater removal efficiency for each of the items, the $BOD_5$ treatment efficiency was the greatest at 97.3% and the color & TN treatment efficiency was 40~70%. The study of the economical assessment showed that the complex as well as the individual companies spent 722~1,298 won for each ton of treated wastewater. All of the wastewater treatment facilities spent the most money on chemicals needed to treat the wastewater. The total cost for Nylon manufacturing wastewater treatment plant was the greatest while the total cost for cotton manufacturing wastewater treatment plant turned out to the lowest. As respects of removal efficiency and economocal assessment, Polyester A and Cotton manufacturing wastewater treatment plants were better effective than a dyeing industrial complex wastewater treatment plant.

생물응집제로서 폐영지박 Chitosan-glucan 복합물의 이용성 (Utilization of Chitosan-glucan Complex Extracted from Ganoderma Iucidum Wastes as Bioflocculant)

  • 오준현;조홍연;양한철
    • 한국미생물·생명공학회지
    • /
    • 제23권6호
    • /
    • pp.770-776
    • /
    • 1995
  • For the purpose of development of non-toxic and biodegradable flocculant, chitosan complex was isolated from Ganoderma lucidum wastes. The isolated complex was identified as the expected chitosan-glucan complex by IR specta. The complex was extracted by treatment of 50% NaOH solution at 120$\circ$C for 5 hrs, namely optimal condition and solubilized with 2% acetic acid for fur-ther use as flocculant. Preliminary experiments showed that the solubilized complex had higher flocculation activity of 1.3 fold than commercial chitosan at 400 mg/l concentration in soybean curd wastewater. Also the solubilized complex removed 83% of MLSS and 60% of COD in the soybean curd wastewater treated by photosynthetic bacteria, 50% of turbidity and 21% of MLSS in sugar industry wastewater, and 90% of turbidity and 89% of MLSS in alcohol fermentation wastewater. Bacterial cell flocculation activities of the solubilized chitosan-glucan complex were 89% in Bacillus subtilis broth, 81% in Streptococcus lactis broth, and more than 90% in Escherichia coli broth after standing for 2 days. The results reveal that chitosan-glucan complex from Ganoderma lucidum wastes can substitute for commercial chitosan as non-toxic and biodegradable flocculant.

  • PDF

Alum과 PACl을 이용한 응집처리 (Chemical Coagulation Treatment Using Alum and PACl in Complex Wastewater)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제35권1호
    • /
    • pp.53-57
    • /
    • 2009
  • In order to treat the complex wastewater containing organic compound and solids, pre-treatment system associated with molecular separation process were investigated. The reductions of COD and turbidity were obtained after coagulation processes using Alum (Aluminium sulfate, $Al_2(SO_4)_2{\cdot}18H_{2}O$) and PACl (poly aluminium chloride as 17% $Al_{2}O_{3}$). The results of study were as follows: using variable dosage of Alum, COD removal was highest at 4,000 mg/l, and the reduction of COD and turbidity was 42% and 92%, respectively. The optimum coagulation would be effective at pH 7.3 than pH 9.0 by the addition of alum at a concentration of 6,000 mg/l and PACl was add at 4.25% in raw complex wastewater with 2,000 mg/l alum at pH 7.3, the reduction of COD was reduced by 32%. But coagulation aid experiments indicated that PACl would be more effective in sludge separation ability than COD removal efficiency.

Biological Removal of EG from Weight Loss Treatment Wastewater & Complex Dyeing Process Wastewater

  • 이현욱;임동준
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.505-508
    • /
    • 2001
  • An microorganism able to degrade ethylene glycol(EG) was developed. Using this microorganism, biological treatment of ethylene glycol was studied in Erlenmeyer flasks and a laboratory scale stirred loop bioreactor. The removal efficiencies of ethylene glycol from synthetic wastewater were 91.6% ${\sim}$ 97.7% at $30^{\circ}C$ ${\sim}$ $40^{\circ}C$, and 96.3% ${\sim}$ 97.9% at initial pH 9 ${\sim}$ 11 respectively. Also the removal efficiencies of ethylene glycol were found to be more then 92% at initial ethylene glycol concentration of 300mg/L ${\sim}$ I400mg/L. In treatment of weight loss treatment wastewater using Erlenmeyer flasks, the removal efficiencies of ethylene glycol were 79.6%. 82.5%. 77.6%. and 71.3% at initial pH 9. 10. 11. and 12.4 after 11 days of reaction. Moreover in treatment of complex dyeing process wastewater. the residual ethylene glycol was not detected at the initial pH 10.0 and pH 11.3 after 4 days of reaction. When stirred loop bioreactor was used for removing ethylene glycol, the residual ethylene glycol was not detected after 108 hrs and 60 hrs of reaction in batch treatment of weight loss treatment wastewater and complex dyeing process wastewater.

  • PDF

농공단지 조성에 따른 하천 수질관리 대책에 관한 연구 (충청남도 지역을 중심으로) (A Study on the Control of Stream Water Pollution Caused by Construction of the Industrial Complex in Agricultural Area (Centering around Area of chung chong Nam Do))

  • 양천회
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.155-160
    • /
    • 1994
  • A study of stream pollution caused by construction of the Industrial Complex in Agricultural Area of Chung Chong Nam Do were descrived here. The five main results of this studies are summerized. First, since 1988, among the companies moved in the industrial complex area, the number of electric and electronic companies have increased compared with food companies requiring much BOD. This Is very desirable to reduce the water pollution. Second, the average Biochemical Oxygen Demand(BOD) of Masan stream was the highest and it was decreased in the order of Yudug, Jo and Jungan stream. Third, although the concentration of heavy metals such as Cd and C $r^{6+}$ are not off the limit and the amount of it is small, it is desirable to introduce a chemical process to remove these metals. Fourth, since the wastewater from industrial complex area is the major factor in stream pollution, the laws associated with environmental protection should be enforced even then if the Industrial complex area with food and chemical companies produce wastewater less than 500ton/day. Fifth, it is required to improve a facilities which separete living wastewater from inderstrial wastewater In Kaya-gok and Nojang industrial complex areas.

  • PDF

침전법과 흡착법을 이용한 중금속 처리 (Treatment of Heavy Metal Wastewater by Pricipitation and Adsorption)

  • 심순보;이요상
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1992년도 수공학연구발표회논문집
    • /
    • pp.325-328
    • /
    • 1992
  • The purpose of this research is to develop the technique of heavy metal removal from wastewater. The research is divided into two parts, one part uses complex precipitation and the other uses adsorption. In the first part of the study, humic acid is used as the complex agent, humic acid is a polyelectrolyte with a high complexation affinity. Lead, copper, zinc and cadmium were studied for their complex precipitation efficiencies. In the batch studies, humic acid was effective in removing 100% of the lead and 48.2% of the copper respectively from wastewater without anytreatment. The efficiency of cadmium and zinc, however, was very low. In the second part of the study, wastewater is introduced at the top of a silicagel adsorption column and then bottom effluent concentration is analyzed. The results of the analysis are used to draw a breakthrough curve.

  • PDF

유기성 슬러지 처리 시스템에 관한 융합연구 (Convergence Study on Organic Sludge Treatment System)

  • 한두희
    • 한국융합학회논문지
    • /
    • 제11권10호
    • /
    • pp.213-217
    • /
    • 2020
  • 천연 광물질, 식물질, 정수장 슬러지를 이용하여 친환경적인 수수질정화제와 이를 활용하는 오폐수복합처리시스템을 개발하였다. 오폐수복합처리시스템은 오염수 유입, 수질정화제 투입, 가압부상장치 가동, 슬러지 부상, 슬러지 수거 및 처리수 배출의 과정을 거친다. 이 장치를 축분 탈리액, 육계 세척수, 공장 폐수, 하수종말처리장 및 연못의 녹조제거에 적용하여 우수한 제거율을 얻었다. 유기성 폐기물 정화에 천연 수질정화제를 활용한 예는 조사되지 못했다.

여수석유화학산단 산업폐수 재이용을 위한 블로우 다운 (Blow Down)수 발생현황 조사 (Quantitative and Qualitative Assessment of Blow Down Wastewater from Yeosu Industrial Complex)

  • 권태옥;문일식
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.289-296
    • /
    • 2005
  • Purpose of this research is to quantitatively and qualitatively investigate the blow down wastewater produced from Yeosu Industrial Complex. Approximately, 38,325,000 tons/year of wastewater is produced, processed and finally discharged. Six representative companies, namely, A, B, C, D, E, F were chosen for this study. Each company produce over 5,000 tons/day of wastewater. In total, 6,844 tons/day of blow down water is produced from these six companies, put together. However, companies A and C produce about 24% and 37% of blow down water, respectively. It was found that the blow down water had favorable qualities, except for its high conductivity, ranging from 230 to $1,700{\mu}s/cm$. It was evident that, this water can be suitable for reuse, for industrial purposes, if a suitable treatment, for example, RO membrane process is adopted to remove high conductivity.

물옥잠을 이용한 수중처리방법에 의한 농공단지 폐수처리에 관한 연구 (Study on the Wastewater Treatment by Floating Aquatic Plant System Using Water Hyacinth for the Industrial Complex in Rural Area)

  • 윤춘경;김형중;류재현;여운식
    • 한국농공학회지
    • /
    • 제39권3호
    • /
    • pp.64-71
    • /
    • 1997
  • Floating aquatic plant system using water hyacinth was applied to examine feasibility as a wastewater treatment system for the industrial complex in rural area. The wastewater from the industrial complex does not likely contain toxic pollutants because the industries which generate wastewater with toxic compounds are not allowed to move in. Pilot plant was installed at Baeksuk Nongkong Danzi in Chunahn-City, Chunchungnam - Do , and field study was performed during summer and fall of 1996. Hydraulic loading rate was 0. $0.19m^3/m^2$.day. The effluent concentration of DO was higher than influent, and it implies that 0.6m depth reactor was reaerated enough to increase DO level. The influent concentration of BOD varied significantly from less than 30 to 120mg/${\ell}$ during the study period, however, effluent concentrations were generally lower than the water quality standard and removal efficiency was up to 85%. The influent concentration of COD also showed wide variation from less than 40 to 160mg/${\ell}$ and effluent concentration was higher than water quality standard when influent concentration was over l00mg/${\ell}$. The influent concentrations of T-N and T-P were lower than water quality standard and no further treatment was required, and these compounds were also removed in the system. Although some improvement and refinement are still required, overall* the floating aquatic plant system was proved to be feasible to apply to treat wastewater from industrial complex in rural area.

  • PDF