• Title/Summary/Keyword: complex wastewater

Search Result 218, Processing Time 0.032 seconds

Studies on the Effluent Characteristics of Dyeing Wastewater by Textile Classification (섬유 형태에 따른 염색폐수 배출특성 연구)

  • Lee, Soo-Hyung;Park, Jung-Min;Park, Sang-Jung;Jeong, Je-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.881-888
    • /
    • 2007
  • In order to investigate the characteristics of the non-biodegradable material, the $BOD_5/COD_{Cr}$ ratio was used. The average ratio of industrial complex's influent wastewater was 2.29~2.96, the effluent ratio was 4.29~19.0. The removal efficiency of $UV_{254}$ by physicochemical treatment was 22.8~94.7% and 5.3~77.2% by biological treatment, respectively. Of the wastewater removal efficiency for each of the items, the $BOD_5$ treatment efficiency was the greatest at 97.3% and the color & TN treatment efficiency was 40~70%. The study of the economical assessment showed that the complex as well as the individual companies spent 722~1,298 won for each ton of treated wastewater. All of the wastewater treatment facilities spent the most money on chemicals needed to treat the wastewater. The total cost for Nylon manufacturing wastewater treatment plant was the greatest while the total cost for cotton manufacturing wastewater treatment plant turned out to the lowest. As respects of removal efficiency and economocal assessment, Polyester A and Cotton manufacturing wastewater treatment plants were better effective than a dyeing industrial complex wastewater treatment plant.

Utilization of Chitosan-glucan Complex Extracted from Ganoderma Iucidum Wastes as Bioflocculant (생물응집제로서 폐영지박 Chitosan-glucan 복합물의 이용성)

  • 오준현;조홍연;양한철
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.6
    • /
    • pp.770-776
    • /
    • 1995
  • For the purpose of development of non-toxic and biodegradable flocculant, chitosan complex was isolated from Ganoderma lucidum wastes. The isolated complex was identified as the expected chitosan-glucan complex by IR specta. The complex was extracted by treatment of 50% NaOH solution at 120$\circ$C for 5 hrs, namely optimal condition and solubilized with 2% acetic acid for fur-ther use as flocculant. Preliminary experiments showed that the solubilized complex had higher flocculation activity of 1.3 fold than commercial chitosan at 400 mg/l concentration in soybean curd wastewater. Also the solubilized complex removed 83% of MLSS and 60% of COD in the soybean curd wastewater treated by photosynthetic bacteria, 50% of turbidity and 21% of MLSS in sugar industry wastewater, and 90% of turbidity and 89% of MLSS in alcohol fermentation wastewater. Bacterial cell flocculation activities of the solubilized chitosan-glucan complex were 89% in Bacillus subtilis broth, 81% in Streptococcus lactis broth, and more than 90% in Escherichia coli broth after standing for 2 days. The results reveal that chitosan-glucan complex from Ganoderma lucidum wastes can substitute for commercial chitosan as non-toxic and biodegradable flocculant.

  • PDF

Chemical Coagulation Treatment Using Alum and PACl in Complex Wastewater (Alum과 PACl을 이용한 응집처리)

  • Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.53-57
    • /
    • 2009
  • In order to treat the complex wastewater containing organic compound and solids, pre-treatment system associated with molecular separation process were investigated. The reductions of COD and turbidity were obtained after coagulation processes using Alum (Aluminium sulfate, $Al_2(SO_4)_2{\cdot}18H_{2}O$) and PACl (poly aluminium chloride as 17% $Al_{2}O_{3}$). The results of study were as follows: using variable dosage of Alum, COD removal was highest at 4,000 mg/l, and the reduction of COD and turbidity was 42% and 92%, respectively. The optimum coagulation would be effective at pH 7.3 than pH 9.0 by the addition of alum at a concentration of 6,000 mg/l and PACl was add at 4.25% in raw complex wastewater with 2,000 mg/l alum at pH 7.3, the reduction of COD was reduced by 32%. But coagulation aid experiments indicated that PACl would be more effective in sludge separation ability than COD removal efficiency.

Biological Removal of EG from Weight Loss Treatment Wastewater & Complex Dyeing Process Wastewater

  • Lee, Hyeon-Uk;Im, Dong-Jun
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.505-508
    • /
    • 2001
  • An microorganism able to degrade ethylene glycol(EG) was developed. Using this microorganism, biological treatment of ethylene glycol was studied in Erlenmeyer flasks and a laboratory scale stirred loop bioreactor. The removal efficiencies of ethylene glycol from synthetic wastewater were 91.6% ${\sim}$ 97.7% at $30^{\circ}C$ ${\sim}$ $40^{\circ}C$, and 96.3% ${\sim}$ 97.9% at initial pH 9 ${\sim}$ 11 respectively. Also the removal efficiencies of ethylene glycol were found to be more then 92% at initial ethylene glycol concentration of 300mg/L ${\sim}$ I400mg/L. In treatment of weight loss treatment wastewater using Erlenmeyer flasks, the removal efficiencies of ethylene glycol were 79.6%. 82.5%. 77.6%. and 71.3% at initial pH 9. 10. 11. and 12.4 after 11 days of reaction. Moreover in treatment of complex dyeing process wastewater. the residual ethylene glycol was not detected at the initial pH 10.0 and pH 11.3 after 4 days of reaction. When stirred loop bioreactor was used for removing ethylene glycol, the residual ethylene glycol was not detected after 108 hrs and 60 hrs of reaction in batch treatment of weight loss treatment wastewater and complex dyeing process wastewater.

  • PDF

A Study on the Control of Stream Water Pollution Caused by Construction of the Industrial Complex in Agricultural Area (Centering around Area of chung chong Nam Do) (농공단지 조성에 따른 하천 수질관리 대책에 관한 연구 (충청남도 지역을 중심으로))

  • 양천회
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.155-160
    • /
    • 1994
  • A study of stream pollution caused by construction of the Industrial Complex in Agricultural Area of Chung Chong Nam Do were descrived here. The five main results of this studies are summerized. First, since 1988, among the companies moved in the industrial complex area, the number of electric and electronic companies have increased compared with food companies requiring much BOD. This Is very desirable to reduce the water pollution. Second, the average Biochemical Oxygen Demand(BOD) of Masan stream was the highest and it was decreased in the order of Yudug, Jo and Jungan stream. Third, although the concentration of heavy metals such as Cd and C $r^{6+}$ are not off the limit and the amount of it is small, it is desirable to introduce a chemical process to remove these metals. Fourth, since the wastewater from industrial complex area is the major factor in stream pollution, the laws associated with environmental protection should be enforced even then if the Industrial complex area with food and chemical companies produce wastewater less than 500ton/day. Fifth, it is required to improve a facilities which separete living wastewater from inderstrial wastewater In Kaya-gok and Nojang industrial complex areas.

  • PDF

Treatment of Heavy Metal Wastewater by Pricipitation and Adsorption (침전법과 흡착법을 이용한 중금속 처리)

  • 심순보;이요상
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1992.07a
    • /
    • pp.325-328
    • /
    • 1992
  • The purpose of this research is to develop the technique of heavy metal removal from wastewater. The research is divided into two parts, one part uses complex precipitation and the other uses adsorption. In the first part of the study, humic acid is used as the complex agent, humic acid is a polyelectrolyte with a high complexation affinity. Lead, copper, zinc and cadmium were studied for their complex precipitation efficiencies. In the batch studies, humic acid was effective in removing 100% of the lead and 48.2% of the copper respectively from wastewater without anytreatment. The efficiency of cadmium and zinc, however, was very low. In the second part of the study, wastewater is introduced at the top of a silicagel adsorption column and then bottom effluent concentration is analyzed. The results of the analysis are used to draw a breakthrough curve.

  • PDF

Convergence Study on Organic Sludge Treatment System (유기성 슬러지 처리 시스템에 관한 융합연구)

  • Han, Doo-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.213-217
    • /
    • 2020
  • An eco-friendly water purifier was developed using natural minerals, plants, and sludge from water purification plants. A wastewater complex treatment system using this water purification agent was developed. The wastewater complex treatment system goes through the process of inflow of contaminated water, input of water purification agent, operation of a pressurized flotation device, sludge flotation, sludge collection and treatment water discharge. This device was applied to the removal of green algae in livestock desorption liquid, broiler washing water, factory wastewater, sewage treatment plant and pond to obtain excellent removal rate. The use of natural water purification agents for organic waste purification has not been investigated.

Quantitative and Qualitative Assessment of Blow Down Wastewater from Yeosu Industrial Complex (여수석유화학산단 산업폐수 재이용을 위한 블로우 다운 (Blow Down)수 발생현황 조사)

  • Kwon, Tae-Ouk;Moon, Il-Shik
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.289-296
    • /
    • 2005
  • Purpose of this research is to quantitatively and qualitatively investigate the blow down wastewater produced from Yeosu Industrial Complex. Approximately, 38,325,000 tons/year of wastewater is produced, processed and finally discharged. Six representative companies, namely, A, B, C, D, E, F were chosen for this study. Each company produce over 5,000 tons/day of wastewater. In total, 6,844 tons/day of blow down water is produced from these six companies, put together. However, companies A and C produce about 24% and 37% of blow down water, respectively. It was found that the blow down water had favorable qualities, except for its high conductivity, ranging from 230 to $1,700{\mu}s/cm$. It was evident that, this water can be suitable for reuse, for industrial purposes, if a suitable treatment, for example, RO membrane process is adopted to remove high conductivity.

Study on the Wastewater Treatment by Floating Aquatic Plant System Using Water Hyacinth for the Industrial Complex in Rural Area (물옥잠을 이용한 수중처리방법에 의한 농공단지 폐수처리에 관한 연구)

  • 윤춘경;김형중;류재현;여운식
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.3
    • /
    • pp.64-71
    • /
    • 1997
  • Floating aquatic plant system using water hyacinth was applied to examine feasibility as a wastewater treatment system for the industrial complex in rural area. The wastewater from the industrial complex does not likely contain toxic pollutants because the industries which generate wastewater with toxic compounds are not allowed to move in. Pilot plant was installed at Baeksuk Nongkong Danzi in Chunahn-City, Chunchungnam - Do , and field study was performed during summer and fall of 1996. Hydraulic loading rate was 0. $0.19m^3/m^2$.day. The effluent concentration of DO was higher than influent, and it implies that 0.6m depth reactor was reaerated enough to increase DO level. The influent concentration of BOD varied significantly from less than 30 to 120mg/${\ell}$ during the study period, however, effluent concentrations were generally lower than the water quality standard and removal efficiency was up to 85%. The influent concentration of COD also showed wide variation from less than 40 to 160mg/${\ell}$ and effluent concentration was higher than water quality standard when influent concentration was over l00mg/${\ell}$. The influent concentrations of T-N and T-P were lower than water quality standard and no further treatment was required, and these compounds were also removed in the system. Although some improvement and refinement are still required, overall* the floating aquatic plant system was proved to be feasible to apply to treat wastewater from industrial complex in rural area.

  • PDF