• 제목/요약/키워드: complex trace

검색결과 237건 처리시간 0.028초

산업 도시의 산업단지 부지와 주거 지역의 대기 중 호흡성 분진과 구성 미량 원소의 특성 (Characteristics of Atmospheric Respirable Particulate Matters and Trace Elements within Industrial Complex and Residential Sites in an Industrial City)

  • 김모근;신승호;조완근
    • Environmental Analysis Health and Toxicology
    • /
    • 제25권1호
    • /
    • pp.27-40
    • /
    • 2010
  • The current study was designed to scientifically evaluate the atmospheric particulate pollution in residences relative to their proximity to a Korean major iron/metal industrial complex (IMIC). This objective was achieved by measuring the concentrations and elemental composition of particulate matter with aerodynamic diameters equal to or less than 10 ${\mu}m$(PM10) in industrial ambient air from IMIC and residential ambient air with relative proximities to IMIC. The trace metals were analyzed using an inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The industrial mean values exceeded the Korean year/70-${\mu}g/m^3$ standard for PM10, whereas the residential mean values did not. However, the maximum residential values did exceed or were close to the Korean PM10 year standard. For individual elements, the ambient concentrations ranged widely from values in the order of a few $ng/m^3$ to thousands of $ng/m^3$. The residential mean mass concentrations in the PM10 measured in the present study were higher than or similar to those reported in earlier studies. This study suggests that residents in neighborhoods near the IMIC are exposedto elevated particulate levels compared to residents living further away from such a source.

다성분 복소트레이스를 이용한 분극필터 (Polarization Filters Using the Multicomponent Complex Trace Analysis)

  • 김기영;이소영
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.89-94
    • /
    • 2006
  • 다성분 탄성파 자료의 신호/잡음비를 높이기 위한 방법의 일환으로 다성분 복소트레이스 분석법을 이용한 분극필터를 개발하였다. 이 필터는 기존의 방법과는 달리, 실체파 신호의 수평/수직 진폭비와 레일리파 타원율을 이용하여 각 시간 샘플의 선형 및 타원형 성분이 정량적으로 계산되며 낮은 신호/잡음비에도 이상적으로 작동하는 특징이 있다. 합성파 뿐만 아니라 실제 자료에 적용시킨 결과, 기존 분극필터보다 타원형 입자운동의 레일리파가 잘 제거되어 선형의 P파 및 S파 신호를 효과적으로 인지할 수 있음을 보인다.

  • PDF

명령어 자취형 모의실험을 기반으로 하는 마이크로프로세서의 전력 소비에 대한 연구 (A Study on Power Dissipation of The Microprocessor Based on Trace-Driven Simulation)

  • 이종복
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.191-196
    • /
    • 2016
  • 최근에 이르러, 임베디드 시스템 및 모바일 장치 뿐만이 아니라 고성능 마이크로프로세서 및 멀티코어프로세서의 전력 소비량이 매우 중요하게 대두되고 있다. 특히, 스마트폰과 태블릿 PC의 광범위한 사용으로 인하여 프로세서의 저전력 소비가 무엇보다 요구된다. 본 논문에서는 고성능 마이크로프로세서에 대하여 빠른 속도를 갖는 명령어 자취형 (trace-driven) 모의실험기 기반의 전력 측정기를 개발하였다. 본 전력 측정기는 마이크로프로세서를 구성하는 복합 조합회로, 배열구조, CAM 구조를 기반으로 하였으며, SPEC 2000 벤치마크를 입력으로 모의실험을 수행하여 각 벤치마크의 평균 전력 소비량을 측정하였다.

다양한 통계기법을 이용한 대전 1,2 공단지역의 미량금속원소의 특성 연구 (A Study on the Characteristics of Airborne Trace Metal Elements using Diverse Statistical Approaches in the Daejeon 1st and 2nd Industrial Complex Area)

  • 이진홍;장미숙;임종명
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.95-112
    • /
    • 2002
  • A precision analysis was conducted for the quantification of trace metal levels in airborne particulates using ICP-MS. According to our study the quantitative analysis using Whatman grade 41 filters produces more precise and representative values of metal concentrations than that using EPM 2000 filters. The mean concentration of PM 10 analyzed during 1998 ~ 2000 was 82 $\mu$g/m$^3$. The concentrations of human carcinogens such as As and Cr were 8.65 and 25.87 ng/m$^3$, respectively, while those of probable human carcinogens such as Cd and Pb were 3.13 and 219.46 ng/m$^3$, respectively. Time-weighted mean concentration, calculated using surface wind speed and direction, indicated that there were differences between metals of crustal origin and metals of anthropogenic origin. The rectorial concentrations of anthropogenic metals and PM 10 were higher for north -west sector with calm or low wind speed conditions than for any other sector with high wind speed conditions. On the contrary, the rectorial concentrations of crustal metals were high with high wind speed. In addition, the sectorial concentrations of crustal metals were more affected by south-west wind directions, which were compared with those of anthropogenic metals. The enrichment factor (EF) values of many anthropogenic metals were higher than 50, while those of crustal metals were lower than 3, respectively. The concentrations of Cr and Ni in Daejeon industrial complex area were 11 times higher than those in the background site of Kuopio in Finland, while that of Pb in the complex area was 22 times higher, respectively.

Determination and Preconcentration of Copper(Ⅱ) after Adsorption of Its Cupferron Complex onto Benzophenone

  • Lee, Taik-Jin;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권6호
    • /
    • pp.861-865
    • /
    • 2002
  • A sensitive method for the determination of trace copper(II) after the preconcentration by adsorbing its cupferron complex onto microcrystalline benzophenone was developed.Several experimental conditions such as the pH of sample solution,concentration of cupferron, amount of benzophenone and atirring time were optimized. Trace compper(II) in 100mL solution was chelated with $3.0\;{\times}\;10^3$ M cupferron at pH 5.0. After 0.20g benzophenone, The benzophenone adsorbing Cu-cupferron complex was filtered and then Cu-cupferron complex was desorbed in 10 mL ethanol. Copper was determined by a flame atomic absorption spectrophotomethry. The interfering effects of diverse concomitant ions were investigated. Fe(III) interfered seriously with, but the interference by Fe(III) was completely eliminated by adjusting the concentration of copferron to $5.0\;{\times}\;10^3$ M. The detection limit of this method was 8.6${\times}$10 M(5.5 ngmL$^1$). Recoveries of 97% and 96% were obtained for Cu(II) in a stream water and a brass sample, respectively. Based on the results from the experiment. this proposed technique could be applied to the determination of copper(II) in real samples.

용매추출과 원자 흡수분리법에 의한 해수중의 미량 구리의 정량 (Determination of Trace Copper in Seawater by Solvent Extraction and Atomic Absorption Spectrometry)

  • 박종안;정창웅
    • 한국환경보건학회지
    • /
    • 제19권2호
    • /
    • pp.40-45
    • /
    • 1993
  • A solvent extraction system of copper-thiocyanate complex into various types of alkylamines such as secondary, tertiary and quaternary ammonium salt for the determination of trace copper by atomic absorption spectrometry is presented. The maximum extraction of copper shows at 0.1 M-thiocyanate and single extraction with 10 ml of 1% amine-MIBK from 50 ml of aqueous solution is enough to be quantitative for micro amounts of copper. The effect of amine diluents and of diverse ions are also examined.

  • PDF

복잡지형에서의 대기순환모델에 관한 연구 (A Study on the Development of Air Pollution Model Applicable to the Complex Terrain)

  • 윤준용;이성철;홍민선
    • 한국전산유체공학회지
    • /
    • 제2권1호
    • /
    • pp.109-116
    • /
    • 1997
  • The objective of this paper is to develop a computational model for the prediction of the pollutant spread from a mass source over a complex terrain. The model comprises a two-dimensional, steady state flow model and a concentration model which employs the results of the computed flow field. The computational model is applied to predict the spread of pollutants for Sanbon city, and the two cases have been compard with the results of SF/sub 6/ trace experiments.

  • PDF

Application of RTI to Improve Image Clarity of a Trace Fossil Cochlichnus Found from the Jinju and Haman Formations

  • Sangho Won;Dal-Yong Kong
    • 자원환경지질
    • /
    • 제56권4호
    • /
    • pp.397-408
    • /
    • 2023
  • A total of 64 specimens of trace fossils were collected from the Jinju Formation of the construction site of Jinju Aviation Industrial Complex, and from the Haman Formation of Namhae Gain-ri fossil site. The fossils are continuously and regularly meandering sine-curve in shape. The fossil varies in morphology: width between 0.2 and 5.6 mm, wavelength between 1.5 and 28 mm, and amplitude between 0.9 and 7.9 mm; the Jinju specimens are commonly wider than the Haman ones. The ratio of wavelength to amplitude is more or less regular regardless of width of the specimen, and the linear correlation of the ratios shows that the Jinju specimens fit better than the Haman specimens. Taking all morphometric parameters, specimens in all size ranges are temporarily identified as ichnospecies Cochlichnus anguineus. In order to obtain more distinct and clearer images of Cochlichnus, we selected two specimens and applied a new imaging technology RTI. For photography of the trace fossils, 50 to 80 images were taken per set with photometric lighting close to the surface and horizontally. RTI technology clearly showed that the images of tiny fossils were improved: the surface contrast become sharper and messy and unnecessary information disappeared. Currently, RTI technology is used in many fields including preservation of cultural properties and archaeology. As a consequence, we hope to apply this technique to the field of paleontology, especially to the study of trace fossils of very small size.

Determination of Trace Amounts of Nickel(II) with ${\alpha}-(2-Benzimidazolyl))-{\alpha}'{\alpha}$

  • 박찬일;김현수;차기원
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권5호
    • /
    • pp.483-486
    • /
    • 2000
  • A method is described for the fluorimetric determination of nickel, based on the formation of $Ni(II)-\alpha-(2-Benzimidazolyl)-\alpha'$, $\alpha''$ -(N-5-Nitro-2-Pyridylhydrazone)-toluene complex in the presence of a non-ionic surfactant. The complex has practically no fluorescence in the absence of surfactant, but the addition of Triton X-100 makes possible the fluorimetric determination of low concentrations of Ni(II) as it enhances the fluorescenceintensity of the complex by up to about 5-fold. This method is very sensitive and selectrive for the direct determination of nickel ion. The optimum conditions are a Triton X-100 concentration of 2.0 mL(5.0%, v/v) and pH $9.0\pm0.2(ammonium$ chloride-ammonia buffer). The fluorescence is measured at 337 nm of emission wavelength under 300 nm of excitation wavelength. The fluorescence intensity is a linear function of the concentration of Ni(II) in the range 5-70 ng/mL, and the detection limit is 2.0 nm/mL. The proposed method has been successfully applied to the determination of trace amounts of Ni(II) in food and human hair samples.

박육직교축 치차의 설계에 관한 기초적 연구 (Study on the Design of Thin Intersected Axe Gear)

  • 장지연
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권3호
    • /
    • pp.80-87
    • /
    • 1993
  • The various configuration of thin-shaped bevel gears are used usually for such as main reduction gear of the hovercraft. But the reasonable and concise guide to thedesign of the se bevel gears is not yet obtained, since the tooth of bevel gear has complex form. The purpose of these investigation is to be establish the design guide and to propose the desirable configuration form for thin-shaped straight bevel gear. In this report, the desirable configuration is examined experimentally by clearing up the effect of web and rim thickness, rim support condition upon the load distribution and root stress distribution along the tooth trace. The results are summarized as follows. (1) The crowning of tooth trace exerts a significant effect on the root stress distribution of thin-shaped bevel gear. (2) As the desirable configuration of the thin-shaped bevel gear, it is to be recommended that the rim is supported at the heel side of tooth trace. (3) But, as special type, it is desirable that the rim is supported at the toe side.

  • PDF