• Title/Summary/Keyword: complementary signal

Search Result 165, Processing Time 0.025 seconds

A Study on the Design of the Digital Filter Bank Using the Wave Digital Filters (웨이브 디지탈 필터를 이용한 디지탈 필터뱅크의 설계에 관한 연구)

  • 임덕규;한인철;이재석;이종각
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.13 no.2
    • /
    • pp.107-119
    • /
    • 1988
  • An 8-channel digital filter bank with wave digital filters(WDF) is studied. Wave digital filtwr is automatically a directional filter. Using these properties, a new method for organizing the 8-channel digital filter bank is proposed. This will lead to enormous savings in memories for the digital signal processign chip.

  • PDF

Constructing a Noise-Robust Speech Recognition System using Acoustic and Visual Information (청각 및 시가 정보를 이용한 강인한 음성 인식 시스템의 구현)

  • Lee, Jong-Seok;Park, Cheol-Hoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.8
    • /
    • pp.719-725
    • /
    • 2007
  • In this paper, we present an audio-visual speech recognition system for noise-robust human-computer interaction. Unlike usual speech recognition systems, our system utilizes the visual signal containing speakers' lip movements along with the acoustic signal to obtain robust speech recognition performance against environmental noise. The procedures of acoustic speech processing, visual speech processing, and audio-visual integration are described in detail. Experimental results demonstrate the constructed system significantly enhances the recognition performance in noisy circumstances compared to acoustic-only recognition by using the complementary nature of the two signals.

Protocol Verification and Conformance Test for Rail Signal Control Protocol specified in LTS (LTS로 명세화된 철도 신호제어용 프로토콜 검정 및 적합성시험)

  • Seo Mi-Seon;Kim Sung-Un;Hwang Jong-Gyu;Lee Jae-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.581-586
    • /
    • 2003
  • As a very important part in development of the protocol, verification and conformance test for protocol specification are complementary techniques that are used to increase the level of confidence in the system functions. as prescribed by their specifications. In this paper, we verify the safety and liveness properties of rail signal control protocol type 1 specified in LTS(Labeled Transition System) with model checking method, and experimentally prove that it is possible to check for the deadlock, livelock and rechability of the states and actions on LTS. We also propose a formal method on generation of conformance test cases using the concept of UIO sequences from verified protocol specification.

  • PDF

ave PWM Inverter (안정파PWM인버어터를 위한 새로운 디지털방식)

  • 정연택;한경희;이종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.2
    • /
    • pp.80-88
    • /
    • 1988
  • As a method to improve harmonics in the voltage source PWM inverter, 5 level stair case wave method is used. The complementary transistor inverter (CTI) bridge circuit has this characteristics. This circuit required synchronous type 3 level PWM signal. In this paper, the 3 phase PWM digital signals within about 10 modulation error of the natural sampling was caculated, and a ROM table out of it for the digital signal of the control system was made. According to this table, the digital control method was proposed, and DTI circuit operated by this method was reviewed. It was confirmed to make V/F control possible by the select modulation ratio to the frequency.

Sentinel lymph node mapping using tri-modal human serum albumin conjugated with visible dye, near infrared fluorescent dye and radioisotope

  • Kang, Se Hun;Kim, Seo-il;Jung, So-Youn;Lee, Seeyoun;Kim, Seok Won;Kim, Seok-ki
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.62-73
    • /
    • 2015
  • We developed an evans blue-indocyanine green-$^{99m}Tc$-human serum albumin conjugate for sentinel lymph node mapping and we describe its unique potential usage for clinical implications. This conjugate has combined the strengths of visible blue dye, near-infrared fluorescence and radioisotope into one single conjugate without any additional weakness/disadvantage. All the components of evans blue-indocyanine green-$^{99m}Tc$-human serum albumin are safe and of low cost, and they have already been clinically used. This conjugate was stable in the serum, it showed a long retention time in the lymphatic system and the lymph nodes showed a much higher signal-to-noise ratio after the conjugate was injected intradermally into the paw of mice. Both the single-photon emission computed tomography and near-infrared fluorescent images of the mice were successfully obtained at the same time as the excised sentinel lymph nodes showed blue color. The visual color, near-infrared fluorescence and gamma ray from this agent could be complementary for each other in all the steps of sentinel lymph node sampling: exploring and planning sentinel lymph node before excision with visualization of the exact sentinel lymph node location during an operation. Therefore, the triple modal agent will possibly be very ideal for sentinel lymph node mapping because of the high signal-to-noise ratio for non-invasive imaging and its complementary multimodal nature, easy preparation and safety. It is promising for clinical applications and it may have great advantages over the traditional single modal methods.

FGPA Design and SoC Implementation for Wireless PAN Applications (무선 PAN 응용을 위한 FPGA 설계 및 SoC)

  • Kim, Young-Sung;Kim, Sun-Hee;Hong, Dae-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.462-469
    • /
    • 2008
  • In this paper, we design the FPGA (Field-Programmable Gate Array) of the KOINONIA WPAN (Wireless Personal Area Network), and implement the SoC (System on Chip). We use the redundant bits to make a constant-amplitude in a modulator part. Additionally, the SNR (Signal to Noise Ratio) performance of the demodulator is improved by using the redundant bits in decoding steps. The four-million FPGA of the KOINONIA WPAN can be operated at 44MHz frequency. The PER (Packet Error Rate) of the designed FPGA with RF (Radio Frequency) module is below 1% at the -86dB MIPLS (Minimum Input Power Level Sensitivity), and the SNR is about 13dB. The SoC is implemented by using Hynix 0.25um CMOS (Complementary Metal Oxide Semiconductor) process. The size of the SoC is $6.52mm{\times}6.92mm$.

Microwave Instantaneous Frequency Measurement (IFM) Approach Based on an Integrated Photonic Ti:LiNbO3 Y Branch

  • Zhang, Changsheng;Zhang, Jiahong;Zhao, Zhengang
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.361-367
    • /
    • 2020
  • An approach based on an integrated photonic Ti:LiNbO3 Y branch has been proposed, designed, and analyzed for the microwave instantaneous frequency measurement (IFM). By designing the Y branch with length L = 6545 ㎛ and refractive index NTE - NTM = 0.0764, a complementary optical filter with free spectral range (FSR) of 600 GHz is constituted, which results in a maximum measureable frequency of 300 GHz being obtained. Theoretical analysis on the temperature stability of the Ti:LiNbO3 Y branch shows that the FSR variation of the complementary filter is 0.3% for the temperature change of 100 K, which indicates that the IFM approach will have a better stability. All these results demonstrate that the proposed IFM approach has potential capability to be used for the increasingly higher microwave IFM with better stability.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.

Nanogap-Based Electrochemical Detection of Protein, Virus, and Bacteria

  • Park, Dae Keun;Kim, Soohyun;Yun, Kum-Hee;Pyo, Hanna;Kang, Aeyeon;Kim, Daehee;Lee, Cho Yeon;Yun, Wan Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.353.2-353.2
    • /
    • 2016
  • We studied electrochemical detection of Botulinum neurotoxin, Vaccinia virus, and Streptococcus Pneumoniae based on nanogap device. Target bio substances were employed as representative targets of protein, virus, and bacteria, respectively. Redox current generated by ferri/ferrocyanide as an electroactive probe was enhanced according to gap distance which was controlled by surface-catalyzed chemical deposition. We found that enhanced electrochemical signal leads more sensitive signal changes according to selective interaction of target and its complementary elements on the electrode or gap area. In case of Botulinum neurotoxin, the redox signal showed a time-dependent increase due to cleavage of the immobilized peptide which blocked redox cycling. Redox cycling was also hindered by Vaccinia virus and Streptococcus Pneumoniae which were selectively immobilized in the gap area.

  • PDF

A study on the CFT error reduction of switched-current system (전류 스위칭 시스템의 CFT 오차 감소에 관한 연구)

  • 최경진;이해길;신홍규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.5
    • /
    • pp.1325-1331
    • /
    • 1996
  • In this paper, a new current-memory circuit is proposed that reduces the clock feedthrough(CFT) error voltage causing total harmonic distortion(THD) increment in switched-current(SI) systems. Using PMOS transistor in CMOS complementary, the proposed one reduces output distortion current due to the CFT errorvoltage. A proposed current-memory is designed using a 1.2.mu.m CMOS process anda 1MHz sinusoidal signal having a 68.mu.A amplitude current is applied as input (sampling frequency:20MHz). It hasbeen shown from the simulation that the output distortion current effected by the CFT error voltage is reduced by approximately 10 times the error voltage of conventional one, THD is -57dB in case ofappling 1kHz frequency input signalwith 0.5 peak signal-to-bias current ratio.

  • PDF