• Title/Summary/Keyword: compartment

Search Result 1,062, Processing Time 0.024 seconds

Enhanced Lighting Image Cost Saving Multi Compartment Lamp Structure (점등 이미지 차별화 및 원가 절감 다구획 램프 구조 개발)

  • Kim, Hyeong Seon
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.1
    • /
    • pp.32-38
    • /
    • 2022
  • In the automobile industry, lamps are frequently used as a mean to emphasize each company's brand identity. Therefore, many detailed design models have emerged in order to realize a differentiated image in preparation for competitive vehicles. Among them, the design of a multi compartment lighting image concept that realizes light divided in multiple space also being introduced by various manufacturers. In this study, in order to solve the problem of cost and weight rise that the existing multi compartment image lamp has, using TRIZ method such as functional analysis modeling and trimming. Through this process, an idea to minimize cost and weight was derived. As the idea was designed in detail, the formation of light did not go as desired, and the diffusion of light also proceeded differently than intended. In order to overcome this problem, a new concept of corrosion and diffusion structure was applied. Eventually, it overcomes various problems and successfully applied it to a real vehicle. The idea was actually reflected in the "Santa Fe" model. Later, the media focused on the lamps to which the idea was applied, and contributed to the sale of a large number of vehicles by providing consumers with a new light sensibility. During the research process, it was possible to secure a number of patents and knowledge of new design concepts.

Chronic Compartment Syndrome and Stress Fracture (만성구획증후군 및 스트레스 골절)

  • Choi, Chang-Hyuk;Baek, Seung-Hoon;Jang, Il-Woong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.9 no.1
    • /
    • pp.16-21
    • /
    • 2010
  • The prevalence of overuse syndrome in the lower extremity including chronic compartment syndrome and stress fracture is increasing with popularity of sports activities. Chronic compartment syndrome is defined as elevation of the interstitial pressure during exertional activities in a closed osseofascial compartment that results in microvascular compromise and operative procedures can be necessary if conservative treatments fail. Stress fracture can be classified as fatigue and insufficiency fracture; stress fracture occurs by repeated strain under abnormal conditions from the patient's activity whereas insufficiency fracture does by those from a process intrinsic to the bone. Most stress fractures occur in the lower extremity, most commonly in the tibial region. Fatigue fractures begin in athletes with the change in their training programs. The radiographic findings are usually diagnostic or at least strongly suggestive and MRI has proven to be a beneficial diagnostic tool for difficult diagnostic cases. Fatigue fractures are treated with a decrease in activity, but surgical procedure may be necessary in those in anterior cortex of the tibial diaphysis.

  • PDF

Characteristics of Heat Flux in a Compartment Fire - Reduced Scale Test (구획공간 화재의 열유속 특성 - 축소 실험)

  • Kim, Sung-Chan;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.128-133
    • /
    • 2011
  • The present study performs a series of 40 % reduced scale of ISO-9705 fire test to investigate the characteristics of heat flux on the floor level in terms of fire characteristics and location in the compartment. The heat flux was measured with Schmidt-Boelter type heat flux gauge at two locations on the floor level of inside and doorway side of the compartment. Different types of fuel - methane, heptane, toluene, ethanol, polystyrene - were burned in this test series. The measured heat flux inside of the compartment was relatively higher than that of front side as the heat release rate of fire and upper layer temperature increased. The difference of measured heat flux at inside and doorway side increased for high sooty fire. The present study shows that the heat flux distribution at lower layer greatly depend on the thermal radiation from fire and upper layer, not only the upper layer temperature but also various fire characteristics such as composition of combustion gases, soot concentration, ventilation condition and so on.

Internal Changes of Blood Compartment and Heat Distribution in Swamp Buffaloes under Hot Conditions : Comparative Study of Thermo-Regulation in Buffaloes and Friesian Cows

  • Koga, A.;Kurata, K.;Ohata, K.;Nakajima, M.;Hirose, H.;Furukawa, R.;Kanai, Y.;Chikamune, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.6
    • /
    • pp.886-890
    • /
    • 1999
  • From previous studies, there is a strong possibility in buffaloes that the marked increase in blood volume (BV) under hot conditions contributes to heat transportation from the rectum to the skin. The present study was done to clarify changes with environmental temperature on water-shift between blood and extracellular fluid (ECF), heat distribution between the rectum and the skin, and blood flow rates (BFR) at the hind legs (reflecting the skin surface). Four buffaloes and four Friesian cows were successively exposed to three different temperatures of $20^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$. BV and ECF volume were measured with Evans' blue and sodium-thiocyanate dilution methods, respectively. Rectal and subcutaneous (as the skin) temperatures were measured by copper-constantan thermocouples. BFR were measured by a supersonic blood flow meter. With an increase in environmental temperature, skin temperature in buffaloes increased significantly than cows, but rectal temperature was not significantly different between two species. BV, especially plasma compartment, increased significantly in only buffaloes, while ECF volume did not change in both species. BFR increased significantly in buffaloes, but not in cows. From these results, the increased of BV may be caused by water flowing from ECF compartment. The water-shift may induce the increase of BFR and skin temperature. It is suggested in the present study that internal changes of blood compartment in buffaloes contribute to transfer of heat to the skin surface.

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT 에서의 간암-간 대조 곡선의 Simulation)

  • Kim, S.J.;Lee, K.H.;Kim, J.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.271-272
    • /
    • 1998
  • Contrast-enhanced CT has an important role in the assessment of liver lesions. However, the optimal protocol to get most effective result is not clear. The main principle for deciding injection protocol is to optimize lesion detectability by rapid scanning when lesion-to-liver contrast is maximum. For this purpose, we developed a physiological model of contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver was modeled in two paths. This dual supply character distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and the second is by portal vein. It is assumed that only hepatic artery can supply blood to hepatocellular carcinoma (HCC) compartment. It is known that this causes the difference of contrast enhancement between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using computer program Matlab, CT contrast-enhancement curves were simulated. Simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with mean enhancement curves from 24 patients exposed to the same protocols as simulation. These enhancement curves were in a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and analyzed the effects. These may help to optimize the scanning protocols for good diagnosis.

  • PDF

System Dynamics Approach to Epidemic Compartment Model: Translating SEIR Model for MERS Transmission in South Korea (전염병 구획 모형에 대한 시스템다이내믹스 접근법: 국내 MERS 전염 SEIR 모형의 해석 및 변환)

  • Jung, Jae Un
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.259-265
    • /
    • 2018
  • Compartment models, a type of mathematical model, have been widely applied to characterize the changes in a dynamic system with sequential events or processes, such as the spread of an epidemic disease. A compartment model comprises compartments, and the relations between compartments are depicted as boxes and arrows. This principle is similar to that of the system dynamics (SD) approach to constructing a simulation model with stocks and flows. In addition, both models are structured using differential equations. With this mutual and translatable principle, this study, in terms of SD, translates a reference SEIR model, which was developed in a recent study to characterize the transmission of the Middle East respiratory syndrome (MERS) in South Korea. Compared to the replicated result of the reference SEIR model (Model 1), the translated SEIR model (Model 2) demonstrates the same simulation result (error=0). The results of this study provide insight into the application of SD relative to constructing an epidemic compartment model using schematization and differential equations. The translated SD artifact can be used as a reference model for other epidemic diseases.

Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment (축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Experimental and numerical studies on the fire characteristics according to the distance between the fire source and sidewall under the over-ventilated fire conditions. A 1/3 reduced ISO 9705 room was constructed and spruce wood cribs were used as fuel. Fire Dynamics Simulator (FDS) was used for fire simulations to understand the phenomenon inside the compartment. As a result, the mass loss rate and heat release rate were increased due to the thermal feedback effect of the wall in the compartment fire compared to the open fire. As the distance between the fire source and sidewall was reduced, the major fire characteristics, such as maximum mass loss rate, heat release rate, fire growth rate, temperature, and heat flux, were increased despite the limitations of air entrainment into the flame. In particular, a significant change in these physical quantities was observed for the case of a fire source against the sidewall. In addition, the vertical distribution of temperature was changed considerably due to a change in the flow structure inside the compartment according to the distance between the fire source and sidewall.

Acute Compartment Syndrome after Anticoagulant Therapy to Misdiagnosed Deep Vein Thrombosis (오인된 심부 정맥 혈전증에 대하여 항응고제 투여 후 발생한 급성 구획 증후군)

  • Hwang, Seok-Ha;Jeon, Ho-Seung;Woo, Young-Kyun;Lim, Seong-Tae
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.177-181
    • /
    • 2019
  • Acute compartment syndrome, which is an orthopedic emergency, induces irreversible tissue necrosis by increasing the compartment pressure. In serious cases, this event may result in functional impairment, loss of the lower limb, and death by renal failure. When the patient initially presents with pain and swelling that are similar to deep vein thrombosis, a differential diagnosis between the two diseases is very critical. The authors encountered a case of acute compartment syndrome after anticoagulant therapy in a patient presenting with painful swelling of the left leg following a massage that was initially misdiagnosed as deep vein thrombosis. A fasciotomy was performed on this case with satisfactory results. This paper reports this case with a review of the relevant literature.

Permeability of anion-exchange membrane for Cl- ions. Dialysis of hydrochloride acid in the presence of nickel chloride

  • Palaty, Zdenek;Bendova, Helena
    • Membrane and Water Treatment
    • /
    • v.1 no.1
    • /
    • pp.39-47
    • /
    • 2010
  • Using a conventional two-compartment cell with stirrers the separation of an aqueous solution of HCl-$NiCl_2$ by an anion-exchange membrane Neosepta-AFN was investigated. The dialysis process was characterized by the permeability coefficient of the membrane towards to $Cl^-$ ions. This quantity was determined by the numerical integration of equations, which describe the time dependence of the total concentration of $Cl^-$ ions in compartment initially filled with stripping agent (water), combined with an optimizing procedure. The analysis of the experimental results showed that this permeability coefficient is a satisfactory characteristic for the process studied. It can be graphically correlated with the initial acid and initial salt concentrations in the compartment initially filled with acid+salt mixture.

Method for Assessing Forest Carbon Sinks by Ecological Process-Based Approach - A Case Study for Takayama Station, Japan

  • Lee, Mi-Sun
    • The Korean Journal of Ecology
    • /
    • v.26 no.5
    • /
    • pp.289-296
    • /
    • 2003
  • The ecological process-based approach provides a detailed assessment of belowground compartment as one of the major compartment of carbon balance. Carbon net balance (NEP: net ecosystem production) in forest ecosystems by ecological process-based approach is determined by the balance between net primary production (NPP) of vegetation and heterotrophic respiration (HR) of soil (NEP=NPP-HR). Respiration due to soil heterotrophs is the difference between total soil respiration (SR) and root respiration (RR) (HR=SR-RR, NEP=NPP-(SR-RR)). If NEP is positive, it is a sink of carbon. This study assessed the forest carbon balance by ecological process-based approach included belowground compartment intensively. The case study in the Takayama Station, cool-temperate deciduous broad-leaved forest was reported. From the result, NEP was estimated approximately 1.2 t C $ha^{-1} yr^{-1}$ in 1996. Therefore, the study area as a whole was estimated to act as a sink of carbon. According to flux tower result, the net uptake rate of carbon was 1.1 t C $ha^{-1} yr^{-1}$.